HomeMy WebLinkAboutAE-101.pdf6
J
H
G
5 4 3 2
F
E
D
C
B
6 5 4 3 2
6
J
H
G
5 4 3 2
F
E
D
C
B
6 5 4 3 2
1
2
3
4
5
6
6
6
6
6
6
7 7
6
6
8 8
48"
36" 36" 36" 9
10
1
2
5
3
4
5
6
7
5
5
5 5 5
5
8
5
5
VESTIBULE
01
TELLER LINE
03
OFFICERS
04
OFFICE
05
OFFICE
09
OFFICE
06
OFFICE
07
OFFICE
08
CONF.
10
FILES
12
RESTROOM
13
ATM
02
ELEC.
11
05
06 08
09
10
11
1
1
1
1
1
2
3
38" 38" 40" 54" 34" VIF
36"
1
1
ALIGN
62"
EQ EQ EQ
EQ EQ EQ
9
9
9
9
9
10
11
6 6 6
9
10
12
CONSTRUCTION KEYED NOTES
1. RESKIM WALL, PAINT, & PROVIDE POWER FOR NEW SIGN BY OWNER, SHERWIN WILLIAMS, PROMAR 400, EGGSHELL, COLOR TBD.
2. PROVIDE NEW CHECK WRITING TRANSACTION TOP w/ TRASH INSERTS ON EXISTING BASE. SEE 2/AE-301.
3. PROVIDE NEW CUSTOM NEWSPAPER RACK, RE: 9/AE-301.
4. PROVIDE (2) NEW VERTICAL NOTICE BOARDS, STACKED ONE OVER THE OTHER. DISPLAYS4SALE.COM, #SBBI, 12"x 18", SATIN SILVER
5. PROVIDE NEW BROADLOOM CARPETING THROUGHOUT. REINSTALL EXISTING WOOD BASE AS REQ'D.
6. NEW CREDENZA BY OWNER.
7. PROVIDE NEW TV or PROJECT SCREEN - TBD BY OWNER. J-BOX MOUNTING HEIGHT PER SELECTION.
8. REPAINT RESTROOM, SHERWIN WILLIAMS, PROMAR 400, EGGSHELL,COLOR TBD.
9. NEW FURNITURE LOCATION - PROVIDE NEW FIRE RATED POKE-THRU DEVICE.
10. NEW FURNITURE LOCATION - PROVIDE NEW POKE-THRU DEVICE.
11. PROVIDE NEW SEMI - RECESSED FIRE EXTINGUISHER CABINET. MOUNT w/ HANDLE AT 3'6" AFF.
12. RELOCATED WINDOW WALL. NOTE: THERE IS NO CELING TO WHICH TO BRACE. MAY NEED TO MODFIY WALL TO PROVIDE SUPPORT.
COORDINATE DESIGN MEETING w/ ARCHITECT & OWNER.
#
CONSTRUCTION LEGEND
AREA NOT IN SCOPE OF WORK
EXISTING WALL TO REMAIN
NEW WALL, REFER TO PARTITION TYPE
NEW TELEPHONE/DATA J-BOX
NEW DUPLEX J-BOX
DEMOLITION LEGEND
AREA NOT IN SCOPE OF WORK
EXISTING WALL TO REMAIN
WALL TO BE DEMOLISHED
ITEM TO BE DEMOLISHED
FEC EXISTING FIRE EXTINGUISHER CABINET
TO REMAIN
DEMO KEYED NOTES
1. REMOVE EXISTING OVERHEAD CABINETS & EXISTING WALL COVERING.
2. REMOVE EXISITNG MAGAZINE STAND AND NOTICE BOARD.
3. REMOVE EXISTING CHECKSTAND TOP; BASE TO REMAIN.
4. REMOVE ONE SECTION OF EXISTING WOOD & GLASS WING WALL. REPAIR & RESTAIN WOOD END CONDITION TO ACHIEVE A
FINISHED APPEARANCE.
5. REMOVE ENTIRE WING WALL & RELOCATE PER PROPOSED PLAN. REPAIR & RESTAIN END CAPS AS NECESSARY.
6. REMOVE CARPETING THROUGHOUT. REMOVE & SAVE WOOD BASE FOR RESINTALLATION.
7. REMOVE DOOR w/ HARDWARE & SAVE FOR REUSE.
8. REMOVE PORTION OF WOOD & GLASS WALL. LEAVE HEADER & CORNER POST IN PLACE IF POSSIBLE. CONSIDER SALVAGING
MATERIALS FOR REUSE AS APPROPRIATE.
9. PROVIDE NEW 4"X8" OPENING FOR FLOOR DIFFUSER W/ FIRE DAMPER PER MECH DWGS.
10. PROVIDE NEW 24"x10" OPENING FOR FLOOR DIFFUSERS W/ FIRE DAMPER PER MECH DWGS.
#
Project Number:
Drawn By:
Checked By:
Sheet Title:
Sheet Number:
Project:
Issues & Revisions:
KENNEY ARCHITECTS, P.C.
5570 EAST YALE AVE
DENVER, COLORADO 80222
303.694.2445 FAX 303.565.1494
www.kenneyarchitects.com
STAMP:
CONSULTANT:
COPYRIGHT: 2014
THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN
CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS
DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE
PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF
KENNEY ARCHITECTS, P.C.
1/5/2015 11:35:35 AM
AE-101
DEMO & PROPOSED FLOOR
PLANS
14024
FIRST BANK VAIL
TENANT IMPROVEMENT
JWM
AMK
17 VAIL ROAD
VAIL, COLORADO 81657
1/8" = 1'-0"
1
DEMOLITION PLAN
1/8" = 1'-0"
2
PROPOSED PLAN
N
N
No. Description Date
OWNER REVIEW 10.27.14
PERMIT / CONSTRUCTION DOCUMENTS 11.10.14
01/15/15