HomeMy WebLinkAboutGI-001.pdf6
J
H
G
5 4 3 2
F
E
D
C
B
6 5 4 3 2
1
101
ROOM
101
A101
1
SIM
1
A101
SIM
1
A101
SIM
SYMBOL LEGEND
ELEVATION TAG
WALL SECTION TAG
DETAIL/CALLOUT TAG
ROOM TAG
DOOR TAG
A WINDOW TAG
WALL TAG
CEILING HEIGHT
9'-0"
CL CENTERLINE
1 EQUIPMENT TAG Project Number:
Drawn By:
Checked By:
Sheet Title:
Sheet Number:
Project:
Issues & Revisions:
KENNEY ARCHITECTS, P.C.
5570 EAST YALE AVE
DENVER, COLORADO 80222
303.694.2445 FAX 303.565.1494
www.kenneyarchitects.com
STAMP:
CONSULTANT:
COPYRIGHT: 2014
THIS DOCUMENT AND THE DESIGNS INCORPORATED HEREIN
CAN ONLY BE USED FOR THIS PROJECT. NO OTHER USE OF THIS
DOCUMENT OR THE DESIGNS, IN WHOLE OR PART, ARE
PERMITTED WITHOUT THE WRITTEN AUTHORIZATION OF
KENNEY ARCHITECTS, P.C.
1/5/2015 11:35:37 AM
GI-001
COVER SHEET
14024
FIRST BANK VAIL
TENANT IMPROVEMENT
JWM
AMK
17 VAIL ROAD
VAIL, COLORADO 81657
FIRST BANK VAIL
TENANT IMPROVEMENT
17 VAIL ROAD
VAIL, COLORADO 81657
PROJECT TEAM
CLIENT
ADAM SNYDER
adam.snyder@efirstbank.com
12345 WEST COLFAX AVE
LAKEWOOD, COLORADO 80215
303.235.1324
ARCHITECTS
ANDREW KENNEY, AIA
a.kenney@kenneyarchitects.com
JENNIFER MCDANIEL, AIA, LEED AP
jmcdaniel@kenneyarchitects.com
KENNEY ARCHITECTS, P.C.
5570 EAST YALE AVE
DENVER, COLORADO 80222
303.694.2445
MECHANICAL ENGINEERS
DENISE DIHLE, PE
ddihle@360eng.com
TAYLOR REESE, PE
treese@360eng.com
THREE SIXTY ENGINEERING, INC.
1600 JACKSON STREET, SUITE 360
GOLDEN, COLORADO 80401
303.940.2050
SITE LOCATION
N
SHEET INDEX
GENERAL INFORMATION
GI-001
GI-002
COVER
TENANT IMPROVEMENT SPECIFICATIONS
ARCHITECTURAL
AE-101
AE201
AE-301
DEMO & PROPOSED FLOOR PLANS
DEMO & PROPOSED REFLECTED CEILING PLANS
PARTITION, DOOR, & FRAME TYPES AND MILLWORK DETAILS
OWNER REVIEW
IAW
EL
ELEC
EA
EWC
ETR
EQ
EXH
FD
FBO
FT
FND
FLR
FIN
FV
FTG
GC
GALV
GA
GR
GND
GL
GYP
GWB
HR
HORIZ
HM
HTR
HT
HDWR
INSUL
ID
JAN
INT
JT
JST
IC
GEN
BEARING
DIAMETER
DIA
EXPANSION JOINT
EXISTING
DRAWING
DOWNSPOUT
(E)
EJ
DN
DS
DWG
DTL
DOWN
DETAIL
CONTROL JOINT
CONCRETE MASONRY UNITS
CONTINUOUS
CONCRETE
CERAMIC TILE
CONSTRUCTION
CONC
CONST
CONT
CT
CPT CARPET
CJ
CMU
COL
CLG
COLUMN
CEILING
ABOVE FINISHED FLOOR
AFF
ARCHITECT(URAL)
ALTERNATE
ASPHALT
ALUMINUM
BOTTOM OF
BUILDING
BOARD
BD
BLDG
BM
BO
BRG
BOT
BLK
BEAM
BOTTOM
BLOCK
ASPH
ARCH
AL
ALT
CENTER LINE
ADJUSTABLE
AIR CONDITIONING
DIAMETER
~
>
#
AC
ADJ
PLATE
NUMBER
<
@
L
AT
ANGLE
TOP OF
TOP OF SLAB
SCHEDULE
SECTION
SPECIFICATIONS
SHEET METAL
SQUARE
SIMILAR
SHEET
SQUARE FEET OR FOOT
STEEL
SYMMETRICAL
SUSPENDED ACOUSTICAL TILE
STRUCTURAL
STANDARD
TOPOGRAPHY
TOP OF FOOTING
TOP OF BEAM
THICKNESS
TELEPHONE
STAINLESS STEEL
TOP OF WALL
VARIES
TYPICAL
VESTIBULE
VINYL WALLCOVERING
VINYL COMPOSITION TILE
UNLESS NOTED OTHERWISE
WATER HEATER
WATER CLOSET
WITHOUT
TOS
OPPOSITE
OPP
GROUND
PART BRD
RAD
INSIDE CLEAR
INSIDE DIAMETER
JOINT
INSULATION
JANITOR
INTERIOR
JOIST
RM
RO
RE
RD
REQD
REINF
RB
IN ACCORDANCE WITH
GYPSUM WALL BOARD
HORIZONTAL
HOUR
HEATER
HEIGHT
GRADE
GYPSUM
HOLLOW METAL
HARDWARE
PTN
PT
PR
PLWD
PERF
PL
PLAM
PC
RADIUS
ROOM
ROUGH OPENING
REFER TO
REQUIRED
REINFORCING
ROOF DRAIN
RUBBER BASE
WH
WD
WC
W/O
WOOD
PLASTIC LAMINATE
PRECAST CONCRETE
PARTICLE BOARD
PARTITION
PLYWOOD
PAINT
PAIR
PROPERTY LINE
PERFORATED
VWC
VCT
VEST
W/ WITH
VAR
UNO
TYP
TOW
MISC
FLOOR DRAIN
GENERAL CONTRACTOR
FIELD VERIFY
GAUGE
GALVANIZED
GLASS
GENERAL
FLOOR
FINISH(ED)
FOOTING
FOOT OR FEET
FOUNDATION
OD
OC
OA
OH
OPG
(N)
MTL
NTS
NOM
NIC
EXISTING TO REMAIN
FURNISHED BY OWNER
ELECTRIC WATER COOLER
EQUIPMENT
EXHAUST
ELECTRIC
EACH
ELEVATION
MAX
MATL
MIN
MFR
MECH
LAV
LAM
LT
MISCELLANEOUS
STD
OUTSIDE DIAMETER
OVER ALL
OPENING
OVER HEAD
ON CENTER
METAL
NOMINAL
NOT TO SCALE
NOT IN CONTACT
NEW
TEL
TOPO
TOF
TOB
THK
TO
SAT
STRL
STL
SYM
MAXIMUM
MATERIAL
MINIMUM
MANUFACTURER
MECHANICAL
LAMINATE
LAVATORY
LIGHT
SHT
SM
SPEC
SQ
SIM
SS
SECT
SCHED
SF
ABOVE FINISHED ROOF
AFR
UNLESS OTHERWISE NOTED
UON
ABBREVIATIONS
PROJECT DESCRIPTION
THE PROPOSED CONSTRUCTION WILL BE A MODEST TENANT IMPROVEMENT INCLUDING THE RELOCATION OF
DESKS, THE ENCLOSURE OF TWO OFFICES, ADDITION OF NEW OFFICE CEILINGS, AND CREATION OF A NEW
CONFERENCE ROOM.
CODE ANALYSIS
APPLICABLE CODES - AS ADOPOTED BY THE CITY OF VAIL
2012 INTERNATIONAL BUILDING CODE
2012 INTERNATION FIRE CODE
2012 INTERNATIONAL MECHANICAL CODE
2012 INTERNATIONAL PLUMBING CODE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
2012 INTERNATIONAL FUEL GAS CODE
2012 PERFORMANCE CODE FOR BUILDING AND FACILITIES
2011 NATIONAL ELECTRIC CODE
GENERAL CONTRACTORS
TBD
KEY PLAN
SITE LOCATION
NOT IN
SCOPE
N
FIRE REQUIREMENTS
LIGHT HAZARD OCCUPANCY
SPRINKLER SYSTEM - NO
FIRE EXTINGUISHERS
REQUIRED: (2) II-A EXTINGUISHERS
PROVIDED: (2) II-A EXTINGUISHERS
CONTRACTOR TO RECHARGE AS REQUIRED
(TABLE 906.3, 2009 IBC)
BUILDING INFORMATION
CONSTRUCTION TYPE: II-B
BUILDING HEIGHT: 2 STORIES + BASEMENT &
PARKING BELOW GRADE
OCCUPANCY CLASSIFICATION - BUSINESS GROUP B
(SECTION 304, 2012 IBC)
ALLOWABLE OCCUPANT LOAD:
BASEMENT: 3,097 SF/ 300 = 10.32 (Storage)
1,063 SF /100 = 10.63 (Business)
MAIN FLOOR: 7,923 SF/100 = 79.23
SECOND FLOOR: 1,282 SF/ 100 = 12.82
TOTAL: 113 PERSONS
(TABLE 1004.1.2, 2012 IBC)
EXIT REQUIREMENT - 2 PER 1-500 OCCUPANTS
EXISTING EMERGENCY EXITS - 2
(TABLE 1021.1, 2009 IBC)
MECHANICAL
M-001
M-002
M-101
M-102
M-201
M-202
MECHANICAL LEGEND & NOTES
MECHANICAL DETAILS
BASEMENT MECHANICAL/DEMOLITION PLAN
BASEMENT MECHANICAL PIPING PLAN
MAIN FLOOR MECHANICAL/ DEMOLITION PLAN
FIRST FLOOR MECHANICAL PIPING PLAN
ALL EXISTING TO REMAIN
113/2 = 57 PERSONS PER GENDER
WATER CLOSETS
REQUIRED: 3 PER GENDER
PROVIDED: 3 PER WOMEN, 1 WC + 1 URINAL
PER MEN, 1 ADA UNISEX
LAVATORIES
REQUIRED: 2 PER GENDER
PROVIDED: 3 PER WOMEN, 2 PER MEN, 1 ADA
UNISEX
FIXTURE COUNTS
No. Description Date
OWNER REVIEW 10.27.14
PERMIT / CONSTRUCTION DOCUMENTS 11.10.14
01/15/15