Loading...
HomeMy WebLinkAboutAA.pdfJS Environmental LLC. Industrial Hygiene and Environmental Consulting July 15, 2014 Mr. Erik Garcia Preconstruction Assistant R.A. Nelson 51 Eagle Road #2 Avon, CO 81620 Subject: Asbestos Survey Results – Lobby Area at 44 W. Meadow Drive, Vail, CO Dear Mr. Garcia: JS Environmental, LLC (JS Environmental) is pleased to submit the results from the limited asbestos survey conducted at the subject site. The results are detailed in the sections below. BACKGROUND The lobby area at 44 W. Meadow Drive is being considered for renovation. Prior to renovation demolition activities, RA Nelson requested the building materials be sampled for asbestos. The lobby consists of the following specific areas:  Lobby Entrance  Office  Piano Room  Hallway to Ski Change Room  Ski Change Room  Hallway to Bathrooms  Men and Women’s Bathroom  Kitchen and Dining Area  Pool and Fountain Area Inaccessible areas such as the interstitial space between the ceiling drywall and the second floor, behind walls, and below the ceramic floor tile grout are not included in the survey. If suspect materials are uncovered during renovation demolition in these areas, the materials will need to be sampled under a separate scope of work. SURVEY METHODOLOGY JS Environmental conducted the asbestos survey from the assessable building materials in the Lobby Area on June 26, 2014. Samples of surfacing material were collected using the EPA random sampling protocol outlined in the EPA publication, "Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials" (EPA 560/5-85-030a, October, 1985). The survey methods, results, and limitations are provided below. 5800 W. 38th Avenue Wheatridge, CO 80212 Local: 303.882.5271 Asbestos Survey 2 | Page Before commencing the survey, the inspector discussed the survey approach, the need for unrestricted access and construction related information issues such as building age and prior construction activities with the on-site maintenance representative. The survey consisted of three major activities: visual inspection, sampling, and quantification of building materials. Although these activities are listed separately, they are integrated tasks. Visual Inspection An initial building walk through was conducted to determine the presence and condition of suspect materials that were accessible and/or exposed. Materials that are similar in general appearance were grouped into homogeneous sampling areas. Homogeneous Material Classifications  A preliminary walk through of the building was conducted to determine areas of materials which are visually similar in color, texture, general appearance, and which appeared to have been installed at the same time. Such materials are termed "homogeneous materials" by the EPA. During this walk through, the approximate locations of these homogeneous materials were noted.  Following the EPA inspection protocol, each identified suspect homogeneous material was placed in one of the following EPA classifications: o Surfacing Materials - Sprayed or troweled on surfaces (walls, ceilings, structural members) for acoustical, decorative, or fireproofing purposes. This includes plaster and fireproofing insulation. o Miscellaneous Materials - Other non-friable products and materials such as floor tile and ceiling tile. o Thermal System Insulation - Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, tanks, ducts, and various other components of hot and cold water systems and heating, ventilation, and air conditioning (VAC.) systems. This includes pipe lagging, pipe wrap, block, batt, blanket insulation, cements, muds, gaskets and ropes. (These materials were not sampled as part of the survey.) Friability Classifications Friable and Nonfriable asbestos-containing material (ACM) are defined as follows:  Friable asbestos-containing material: any material containing more than 1% asbestos, determined using PLM analysis, that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.  Category I nonfriable asbestos-containing material: asbestos-containing resilient floor covering containing more than 1% asbestos as determined using PLM.  Category II nonfriable asbestos-containing material: any material, excluding Category I non-friable ACM, containing more than 1% asbestos as determined using PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.  Regulated asbestos-containing material (RACM): (1) friable ACM, (2) Category I nonfriable ACM That has become friable, (3) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (4) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, Asbestos Survey 3 | Page pulverized, or reduced to powder by the forced expected to act on the materials in the course of demolition or renovation operations. Laboratory Samples were tested by Reservoirs Environmental Laboratory, Denver, CO who is accredited through a program by the National Institute of Standards and Technology (NIST), National voluntary Laboratory Accreditation Program (NVLAP). INSPECTION RESULTS Forty two (42) samples of suspect materials were collected from the site (see Table 1). The laboratory analyzed layers of each sample, if present. According to the laboratory analysis of the materials sampled, asbestos was not detected above 1% in any of the samples collected. Table 1. Bulk Sampling Results Sample No. Location Description Lab Sample ID Result 1 Workout Room Ceiling 1 1211595 ND 2 Kit Ceiling 3 1211596 ND 3 Karen Office Wall 1 1211597 ND 4 Karen Wall 2 1211598 ND 5 Workout Ceiling 2 1211599 ND 6 Kit Wall 1 1211600 ND 7 Piano Area Ceiling 1211601 ND 8 Lobby Wall 3 1211602 ND 9 Pool Floor 1 1211603 ND 10 Pool Ceiling 1211604 ND 11 Kitchen Window Caulk 1211605 ND 12 Fountain Stucco 1211606 ND 13 Karen Ceiling 3 1211607 ND 14 Bath Ceiling 2 1211608 ND 15 Pool Wall Stucco 3 Main Level 1211609 ND 16 Pool Area Wall 2 1211610 ND 17 Bath Ceiling 2 (labeled Bath Ceiling 3) 1211611 ND 18 Pool Area Wall 1 1211612 ND 19 Bath 1 Ceiling 1211613 ND 20 Karen Ceiling 2 1211614 ND 21 Hall Ceiling 1 1211615 ND 22 Ski Room Ceiling Closet 1211616 ND 23 Karen Office Ceiling 1 1211617 ND 24 Entry Ceiling 2 1211618 ND 25 Hall Way Ceiling 2 (Labeled as Hallway Ceiling 3) 1211619 ND Asbestos Survey 4 | Page 26 Pool Area Wall 3 1211620 ND 27 Pool Wall By Stairs 1211621 ND 28 Ski Room Wall 2 1211622 ND 29 Ski Room Under Red Flooring 1211623 ND 30 Pool Wall #2 Stucco 1211624 ND 31` Entry Ceiling 3 1211625 ND 32 Ski Room Wall 1 1211626 ND 33 Entry Ceiling 1 1211627 ND 34 Kit Ceiling 1 1211628 ND 35 Workout Ceiling 2 ( Labeled Workout Ceiling 3) 1211629 ND 36 Kit Wall 3 1211630 ND 37 Kit Wall 2 1211631 ND 38 Hall Ceiling 2 In Closet 1211632 ND 39 Pool Area Wall 1211633 ND 40 Hall Wall 3 1211634 ND 41 Karen Office 3 1211635 ND 42 Pool Area Tile 1211644 ND Detailed laboratory results are provided in Attachment A. LIMITATIONS The survey is considered a limited asbestos survey because it did not include comprehensive sampling of the entire building. It should be noted that some ACM might not be accurately identified and/or quantified by PLM. As a result, these fibers could go undetected under the standard polarized light microscopy method. If ACM are identified at a later date and will be disturbed through future maintenance, renovation or demolition activities, the materials will be subject to the requirements set forth in all applicable local, state, and federal regulations. CONCLUSIONS According to the laboratory analysis of the materials sampled, asbestos was not detected above 1% in any of the samples collected and submitted for analysis from the Lobby Area. JS Environmental appreciates the opportunity to be of assistance, if you should have any questions, please contact me at (303) 882-5271. Sincerely, JS Environmental LLC. Jim Stout, Principal Asbestos Survey 5 | Page Attachment A Laboratory Results Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc Subcontract Number:NA Laboratory Report:RES 294226-1 Project # / P.O. #R.A. Nelson Project Description:44 Mergow, Vail CO RES 294226-1 Sincerely, July 11, 2014 Dear Customer, Reservoirs Environmental,Inc.is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP),Lab Code 101896-0 for Transmission Electron Microscopy (TEM)and Polarized Light Microscopy (PLM)analysis and the American Industrial Hygiene Association (AIHA),Lab ID 101533 -Accreditation Certificate #480 for Phase Contrast Microscopy (PCM)analysis.This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental,Inc.has analyzed the following samples for asbestos content as per your request.The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. JS Enviromental LLC 11475 W. Colfax Lakewood CO 80215 Jim Stout is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer.Reservoirs Environmental,Inc.will not discuss any part of this study with personnel other than those of the client.The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S.Government.This report shall not be reproduced except in full,without written approval from Reservoirs Environmental,Inc.Samples will be disposed of after sixty days unless longer storage is requested.If you have any questions about this report, please feel free to call 303-964-1986. Jeanne Spencer President P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 1 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Workout Room Ceiling 1 EM 1211595 A B Gray plaster White texture w/ white paint 5 95 ND ND 0 0 100 100 Kit Ceiling 3 EM 1211596 A B C D White texture w/ white paint White tape White joint compound White/green drywall 5 5 5 85 ND ND ND ND 0 90 0 15 100 10 100 85 Karen Office Wall 1 EM 1211597 A B White texture w/ pink paint White/tan drywall 5 95 ND ND 0 15 100 85 Karen Wall 2 EM 1211598 A B White texture w/ white paint White/tan drywall 5 95 ND ND 0 15 100 85 Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 2 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Workout Ceiling 2 EM 1211599 A B White texture w/ white paint White/green drywall 5 95 ND ND 0 15 100 85 Kit Wall 1 EM 1211600 A B White compound w/ white paint White compound w/ yellow fibrous woven material 5 95 ND ND 0 5 100 95 Piano Area Ceiling EM 1211601 A B C D White texture w/ white paint White tape White joint compound White/tan drywall 5 5 5 85 ND ND ND ND 0 90 0 15 100 10 100 85 Lobby Wall 3 EM 1211602 A B C Blue wall covering w/ white paint White compound White/tan drywall 5 5 90 ND ND ND 5 0 15 95 100 85 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 3 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Pool Floor 1 EM 1211603 A Gray granular resinous material w/ white paint 100 ND 0 100 Pool Ceiling EM 1211604 A B White compound White resinous material 5 95 ND ND 0 0 100 100 Kitchen Window Caulk EM 1211605 A Brown resinous material 100 ND 0 100 Fountain Stucco EM 1211606 A White/multi-colored paint 100 ND 0 100 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 4 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Karen Ceiling 3 EM 1211607 A B White texture w/ white paint White/tan drywall 5 95 ND ND 0 15 100 85 Bath Ceiling 2 EM 1211608 A B C D White texture w/ white paint White tape White joint compound White/tan drywall 5 5 5 85 ND ND ND ND 0 90 0 15 100 10 100 85 Pool Wall Stucco 3 Main Level EM 1211609 A B White paint Gray granular cementitious material 10 90 ND ND 0 0 100 100 Pool Area Wall 2 EM 1211610 A B White compound w/ tan paint White/tan drywall 15 85 ND ND 0 15 100 85 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 5 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Bath Ceiling 2 (labeled Bath Ceiling 3) EM 1211611 A B C D White texture w/ white paint White tape White joint compound White/green drywall 5 5 5 85 ND ND ND ND 0 90 0 15 100 10 100 85 Pool Area Wall 1 EM 1211612 A B C D White joint compound White tape White texture w/ white paint White/green drywall 2 3 5 90 ND ND ND ND 0 90 0 15 100 10 100 85 Bath 1 Ceiling EM 1211613 A B White texture w/ white paint White/green drywall 5 95 ND ND 0 15 100 85 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 6 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Karen Ceiling 2 EM 1211614 A B White texture w/ white paint White/tan drywall 5 95 ND ND 0 15 100 85 Hall Ceiling 1 EM 1211615 A B White texture w/ white paint Tan/green drywall 5 95 ND ND 0 15 100 85 Ski Room Ceiling Closet EM 1211616 A B White compound White/tan drywall 10 90 ND ND 0 15 100 85 Karen Office Ceiling 1 EM 1211617 A B White texture w/ white paint White/tan drywall 5 95 ND ND 0 15 100 85 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 7 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Entry Ceiling 2 EM 1211618 A B White texture w/ white paint White/tan drywall 5 95 ND ND 0 15 100 85 Hall Way Ceiling 2 (Labeled as Hallway Ceiling 3) EM 1211619 A B C D White texture w/ white paint White tape White joint compound Tan/green drywall 5 5 5 85 ND ND ND ND 0 90 0 15 100 10 100 85 Pool Area Wall 3 EM 1211620 A B C White texture w/ white paint White texture w/ white paint Tan/green drywall 5 5 90 ND ND ND 0 0 15 100 100 85 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 8 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Pool Wall By Stairs EM 1211621 A B White paint Gray granular plaster 10 90 ND ND 0 0 100 100 Ski Room Wall 2 EM 1211622 A B White texture w/ blue paint White/tan drywall 5 95 ND ND 0 15 100 85 Ski Room Under Red Flooring EM 1211623 A Tan wood w/ gray resinous material 100 ND 90 10 Pool Wall #2 Stucco EM 1211624 A B White paint w/ white compound Gray granular cementitious material 20 80 ND ND 0 0 100 100 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 9 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Entry Ceiling 3 EM 1211625 A B White compound w/ white paint White/tan drywall 5 95 ND ND 0 15 100 85 Ski Room Wall 1 EM 1211626 A B White texture w/ blue paint White/tan drywall 5 95 ND ND 0 15 100 85 Entry Ceiling 1 EM 1211627 A B White texture w/ white paint White/tan drywall 10 90 ND ND 0 15 100 85 Kit Ceiling 1 EM 1211628 A B White texture w/ white paint Tan/green drywall 5 95 ND ND 0 15 100 85 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 10 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Workout Ceiling 2 ( Labeled Workout Ceiling 3) EM 1211629 A B White texture w/ white paint Tan/green drywall 5 95 ND ND 0 15 100 85 Kit Wall 3 EM 1211630 A B White texture w/ white/blue paint Tan/green drywall 10 90 ND ND 0 15 100 85 Kit Wall 2 EM 1211631 A B White texture w/ white/blue paint Tan/green drywall 5 95 ND ND 0 15 100 85 Hall Ceiling 2 In Closet EM 1211632 A B White texture w/ white paint White/tan drywall 5 95 ND ND 0 15 100 85 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 11 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Pool Area Wall EM 1211633 A B C D White texture w/ white paint White tape White joint compound White/tan drywall 5 5 5 85 ND ND ND ND 0 90 0 15 100 10 100 85 Hall Wall 3 EM 1211634 A B White wall covering w/ white/multi-colored paint Tan/green drywall 5 95 ND ND 5 15 95 85 Karen Office 3 EM 1211635 A B Red wall covering w/ white/red paint White/tan drywall 10 90 ND ND 20 15 80 85 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 12 of 13 1-866-RESI-ENV www.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2014 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Method:ND=None Detected Turnaround:TR=Trace, <1% Visual Estimate Date Analyzed:Trem-Act=Tremolite-Actinolite Client Non Non- Sample Sub Asbestos Fibrous Number Physical Part Fibrous Components Description (%)Mineral Visual Components (%) Estimate (%)(%) Asbestos Content July 3, 2014 44 Mergow, Vail CO EPA 600/R-93/116 - Short, Bulk July 11, 2014 RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 ID Number L A Y E R Lab 3-5 Day RES 294226-1 R.A. Nelson JS Enviromental LLC Tile EM 1211644 A B Tan mastic Brown/cream ceramic tile 5 95 ND ND 0 0 100 100 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. Analyzed by:Data QA: P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 13 of 13 1-866-RESI-ENV www.reilab.com