HomeMy WebLinkAboutB15-0012 Mechanical COMCHECK.pdfProject Title: FORD PARK LOWER BENCH RESTROOMS Report date: 01/07/15 Data filename: P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 1 of 4 COMcheck Software Version 3.9.4 Envelope Compliance Certificate 2012 IECC Section 1: Project Information Project Type: New Construction Project Title : FORD PARK LOWER BENCH RESTROOMS Construction Site:Owner/Agent:Designer/Contractor: 530 SOUTH FRONTAGE ROAD EAST VAIL, CO 81657 TOWN OF VAIL DEPARTMENT OF PUBLIC WORKS VAIL, CO 81657 CARLA PETTIT AEC 40801 U.S. 6 #214 AVON, CO 81620 Additional Efficiency Package: Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Section 2: General Information Building Location (for weather data):Vail, Colorado Climate Zone:6b Building Space Conditioning Type(s):Nonresidential Vertical Glazing / Wall Area Pct.:5% Building Type Floor Area Restrooms (Office)552 Section 3: Envelope Assemblies Envelope PASSES: Design 0.1% better than code. Climate-Specific Requirements: Component Name/Description Gross Area or Perimeter Cavity R-Value Cont. R-Value Proposed U-Factor Budget U-Factor(a) Siding 1 - Wood: Wood-Framed, 16" o.c.1035 20.0 3.8 0.050 0.051 Window 1: Metal Frame with Thermal Break:Fixed, Perf. Type: Other testing/cert. Product ID: NA, SHGC 0.19 (c) 64 ------0.350 0.360 Door 1: Insulated Metal, Swinging 60 ------0.250 0.370 Stone-1: Solid Concrete:8" Thickness,Medium Density , Furring: None 328 ---13.3 0.064 0.078 Louvered area in door: Metal Building Wall, Single Layer Mineral Fiber 3 0.0 0.0 1.180 0.052 Floor 1: Slab-On-Grade:Unheated, Vertical 2 ft.103 ---13.3 ------ Sloped Roof: Attic Roof with Wood Joists 537 49.0 0.0 0.021 0.021 Flat Roof: Attic Roof with Wood Joists 19 49.0 4.0 0.019 0.021 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) 'Other' components require supporting documentation for proposed U-factors. (c) Fenestrations product performance must be certfied in accordance with NFRC and requires supporting documentation. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2012 IECC requirements in COMcheck Version 3.9.4 and to comply with the mandatory requirements in the Requirements Checklist. Project Title: FORD PARK LOWER BENCH RESTROOMS Report date: 01/07/15 Data filename: P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 2 of 4 Name - Title Signature Date Project Notes: COMCHECK PERFORMED BY: AEC ENGINEER: CARLA PETTIT Project Title: FORD PARK LOWER BENCH RESTROOMS Report date: 01/07/15 Data filename: P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 3 of 4 COMcheck Software Version 3.9.4 Mechanical Compliance Certificate 2012 IECC Section 1: Project Information Project Type: New Construction Project Title : FORD PARK LOWER BENCH RESTROOMS Construction Site:Owner/Agent:Designer/Contractor: 530 SOUTH FRONTAGE ROAD EAST VAIL, CO 81657 TOWN OF VAIL DEPARTMENT OF PUBLIC WORKS VAIL, CO 81657 CARLA PETTIT AEC 40801 U.S. 6 #214 AVON, CO 81620 Additional Efficiency Package: Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Section 2: General Information Building Location (for weather data):Vail, Colorado Climate Zone:6b Section 3: Mechanical Systems List Quantity System Type & Description 1 HVAC System 1 (Unknown) : Heating: 1 each - Unit Heater, Electric, Capacity = 7 kBtu/h No minimum efficiency requirement applies Fan System: None 1 HVAC System 2 (Unknown) : Heating: 1 each - Unit Heater, Electric, Capacity = 7 kBtu/h No minimum efficiency requirement applies Fan System: None 1 HVAC System 3 (Unknown) : Heating: 1 each - Unit Heater, Electric, Capacity = 2 kBtu/h No minimum efficiency requirement applies Fan System: None Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2012 IECC requirements in COMcheck Version 3.9.4 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Section 6: Post Construction Compliance Statement q HVAC record drawings of the actual installation and performance data for each equipment provided to the owner within 90 days after system acceptance. q HVAC O&M documents for all mechanical equipment and system provided to the owner within 90 days after system acceptance. q Written HVAC balancing report provided to the owner. Project Title: FORD PARK LOWER BENCH RESTROOMS Report date: 01/07/15 Data filename: P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 4 of 4 The above post construction requirements have been completed. Principal Mechanical Designer-Name Signature Date Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 3.9.4 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2012 IECC 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Data FORD PARK LOWER BENCH RESTROOMS P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 1 of 01/07/1Report date: 9 2012 IECC Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable C103.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Complies Does Not Not Observable Not Applicable C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable C402.3.1 [PR10]1 Vertical fenestration area <= 30 percent of the gross above-grade wall area. Complies Does Not Not Observable Not Applicable C402.3.1 [PR11]1 Skylight area <= 3 percent of the gross roof area. Complies Does Not Not Observable Not Applicable C402.3.2. 2 [PR15]1 Areas with obstructions that block direct beam sunlight on >= 1/2 of the roof over the enclosed area for more than 1,500 daytime hours per year between 8 am and 4 pm. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Data FORD PARK LOWER BENCH RESTROOMS P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 2 of 01/07/1Report date: 9 Section # & Req.ID Footing / Foundation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions C402.2.6 [FO3]2 Slab edge insulation R-value.R-_____ Unheated Heated R-_____ Unheated Heated Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C303.2 [FO4]2 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C402.2.6 [FO5]2 Slab edge insulation depth/length. Slab insulation extending away from building is covered by pavement or >= 10 inches of soil. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C403.2.7, C408.2.8, C404.5 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable C403.2.4. 5 [FO9]3 Freeze protection and snow/ice melting system sensors for future connection to controls. Complies Does Not Not Observable Not Applicable C402.2.8 [FO12]3 Bottom surface of floor structures incorporating radiant heating insulated to >=R-3.5. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Data FORD PARK LOWER BENCH RESTROOMS P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 3 of 01/07/1Report date: 9 Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions C402.4.1, C402.4.2 [FR16]1 The building envelope contains a continuous air barrier that is sealed in an approved manner and either constructed or tested in an approved manner. Air barrier penetrations are sealed in an approved manner. Complies Does Not Not Observable Not Applicable C402.4.3, C402.4.4 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable C402.4.7 [FR17]3 Vestibules are installed on all building entrances. Doors have self-closing devices. Complies Does Not Not Observable Not Applicable C402.3.3, C402.3.4 [FR8]1 Vertical fenestration U-Factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.3.3 [FR10]1 Vertical fenestration SHGC value.SHGC:_____SHGC:_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable C402.2.7 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. U-_____ Swinging Nonswinging U-_____ Swinging Nonswinging Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Data FORD PARK LOWER BENCH RESTROOMS P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 4 of 01/07/1Report date: 9 Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions C403.2.3 [ME55]2 HVAC equipment efficiency verified. Efficiency:_____Efficiency:_____Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C402.4.5. 1 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable C402.4.5. 2 [ME58]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable C403.2.5. 1 [ME59]1 Demand control ventilation provided for spaces >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable C403.2.7 [ME60]2 HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. R-_____R-_____Complies Does Not Not Observable Not Applicable C403.2.8 [ME61]2 HVAC piping insulation thickness. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. _____ in._____ in.Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 1. C403.2.8 [ME61]2 HVAC piping insulation thickness. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. _____ in._____ in.Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 2. C403.2.8 [ME61]2 HVAC piping insulation thickness. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. _____ in._____ in.Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 3. C403.2.8 [ME41]3 Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Complies Does Not Not Observable Not Applicable C403.2.7 [ME10]2 Ducts and plenums sealed based on static pressure and location. Complies Does Not Not Observable Not Applicable C403.2.7. 1.3 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 1. C403.2.7. 1.3 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 2. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Data FORD PARK LOWER BENCH RESTROOMS P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 5 of 01/07/1Report date: 9 Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions C403.2.7. 1.3 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 3. C408.2.2. 1 [ME53]3 Air outlets and zone terminal devices have means for air balancing. Complies Does Not Not Observable Not Applicable C403.4.2 [ME66]2 VAV fan motors >=7.5 hp to be driven by variable speed drive, have a vane-axial fan with variable pitch blades, or have controls to limit fan motor demand. VSD Vane axial fan Other VSD Vane axial fan Other Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 1. C403.4.2 [ME66]2 VAV fan motors >=7.5 hp to be driven by variable speed drive, have a vane-axial fan with variable pitch blades, or have controls to limit fan motor demand. VSD Vane axial fan Other VSD Vane axial fan Other Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 2. C403.4.2 [ME66]2 VAV fan motors >=7.5 hp to be driven by variable speed drive, have a vane-axial fan with variable pitch blades, or have controls to limit fan motor demand. VSD Vane axial fan Other VSD Vane axial fan Other Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 3. C403.2.6 [ME57]1 Exhaust air energy recovery on systems meeting Table C403.2.6 Complies Does Not Not Observable Not Applicable C403.2.11 [ME71]2 Unenclosed spaces that are heated use only radiant heat. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Data FORD PARK LOWER BENCH RESTROOMS P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 6 of 01/07/1Report date: 9 Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions C402.4.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor-permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable C402.4.2. 1 [IN2]1 Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. R-_____ Above deck Metal Attic R-_____ Above deck Metal Attic Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C303.2 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C402.2.5 [IN8]2 Floor insulation R-value.R-_____ Mass Steel Wood R-_____ Mass Steel Wood Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable C402.2.1 [IN17]3 Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Data FORD PARK LOWER BENCH RESTROOMS P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 7 of 01/07/1Report date: 9 2012 IECC Final Inspection Complies?Comments/Assumptions C402.4.6 [FI37]1 Weatherseals installed on all loading dock cargo doors. Complies Does Not Not Observable Not Applicable C403.2.4. 2 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 1. C403.2.4. 2 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 2. C403.2.4. 2 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values for HVAC System 3. C403.2.4. 2 [FI38]3 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable C403.2.4. 2 [FI20]3 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable C403.2.4. 3 [FI39]3 Each zone equipped with setback controls using automatic time clock or programmable control system. Complies Does Not Not Observable Not Applicable C403.2.4. 3 [FI40]3 Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7-day clock, 2- hour occupant override, 10-hour backup Complies Does Not Not Observable Not Applicable C408.2.5. 1 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C303.3,C4 08.2.5.2 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.2.5. 3 [FI43]1 An air and/or hydronic system balancing report is provided for HVAC systems. Complies Does Not Not Observable Not Applicable C408.2.3. 2 [FI10]1 HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Data FORD PARK LOWER BENCH RESTROOMS P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 8 of 01/07/1Report date: 9 2012 IECC Final Inspection Complies?Comments/Assumptions C402.4.8 [FI26]3 Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Complies Does Not Not Observable Not Applicable C403.2.2 [FI27]3 HVAC systems and equipment capacity does not exceed calculated loads. Complies Does Not Not Observable Not Applicable C408.2.1 [FI28]1 Commissioning plan developed by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable C408.2.4 [FI29]1 Preliminary commissioning report completed and certified by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable C408.2.5. 4 [FI30]1 Final commissioning report due to building owner within 90 days of receipt of certificate of occupancy. Complies Does Not Not Observable Not Applicable C408.2.3. 1 [FI31]1 HVAC equipment has been tested to ensure proper operation. Complies Does Not Not Observable Not Applicable C406 [FI34]1 Efficient HVAC performance, efficient lighting system, or on-site supply of renewable energy consistent with what is shown the approved plans. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Data FORD PARK LOWER BENCH RESTROOMS P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck Page 9 of 9 01/07/15Report