HomeMy WebLinkAboutB15-0012 Mechanical COMCHECK.pdfProject Title: FORD PARK LOWER BENCH RESTROOMS Report date: 01/07/15
Data filename: P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD
RESTROOMS.cck Page 1 of 4
COMcheck Software Version 3.9.4
Envelope Compliance Certificate
2012 IECC
Section 1: Project Information
Project Type: New Construction
Project Title : FORD PARK LOWER BENCH RESTROOMS
Construction Site:Owner/Agent:Designer/Contractor:
530 SOUTH FRONTAGE ROAD EAST
VAIL, CO 81657
TOWN OF VAIL DEPARTMENT OF
PUBLIC WORKS
VAIL, CO 81657
CARLA PETTIT
AEC
40801 U.S. 6
#214
AVON, CO 81620
Additional Efficiency Package: Reduced interior lighting power. Requirements are implicitly enforced within interior lighting
allowance calculations.
Section 2: General Information
Building Location (for weather data):Vail, Colorado
Climate Zone:6b
Building Space Conditioning Type(s):Nonresidential
Vertical Glazing / Wall Area Pct.:5%
Building Type Floor Area
Restrooms (Office)552
Section 3: Envelope Assemblies
Envelope PASSES: Design 0.1% better than code.
Climate-Specific Requirements:
Component Name/Description Gross
Area or
Perimeter
Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget
U-Factor(a)
Siding 1 - Wood: Wood-Framed, 16" o.c.1035 20.0 3.8 0.050 0.051
Window 1: Metal Frame with Thermal Break:Fixed, Perf. Type:
Other testing/cert. Product ID: NA, SHGC 0.19 (c)
64 ------0.350 0.360
Door 1: Insulated Metal, Swinging 60 ------0.250 0.370
Stone-1: Solid Concrete:8" Thickness,Medium Density , Furring:
None
328 ---13.3 0.064 0.078
Louvered area in door: Metal Building Wall, Single Layer Mineral
Fiber
3 0.0 0.0 1.180 0.052
Floor 1: Slab-On-Grade:Unheated, Vertical 2 ft.103 ---13.3 ------
Sloped Roof: Attic Roof with Wood Joists 537 49.0 0.0 0.021 0.021
Flat Roof: Attic Roof with Wood Joists 19 49.0 4.0 0.019 0.021
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b) 'Other' components require supporting documentation for proposed U-factors.
(c) Fenestrations product performance must be certfied in accordance with NFRC and requires supporting documentation.
Section 4: Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2012 IECC
requirements in COMcheck Version 3.9.4 and to comply with the mandatory requirements in the Requirements Checklist.
Project Title: FORD PARK LOWER BENCH RESTROOMS Report date: 01/07/15
Data filename: P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD
RESTROOMS.cck Page 2 of 4
Name - Title Signature Date
Project Notes:
COMCHECK PERFORMED BY: AEC
ENGINEER: CARLA PETTIT
Project Title: FORD PARK LOWER BENCH RESTROOMS Report date: 01/07/15
Data filename: P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD
RESTROOMS.cck Page 3 of 4
COMcheck Software Version 3.9.4
Mechanical Compliance Certificate
2012 IECC
Section 1: Project Information
Project Type: New Construction
Project Title : FORD PARK LOWER BENCH RESTROOMS
Construction Site:Owner/Agent:Designer/Contractor:
530 SOUTH FRONTAGE ROAD EAST
VAIL, CO 81657
TOWN OF VAIL DEPARTMENT OF
PUBLIC WORKS
VAIL, CO 81657
CARLA PETTIT
AEC
40801 U.S. 6
#214
AVON, CO 81620
Additional Efficiency Package: Reduced interior lighting power. Requirements are implicitly enforced within interior lighting
allowance calculations.
Section 2: General Information
Building Location (for weather data):Vail, Colorado
Climate Zone:6b
Section 3: Mechanical Systems List
Quantity System Type & Description
1 HVAC System 1 (Unknown) :
Heating: 1 each - Unit Heater, Electric, Capacity = 7 kBtu/h
No minimum efficiency requirement applies
Fan System: None
1 HVAC System 2 (Unknown) :
Heating: 1 each - Unit Heater, Electric, Capacity = 7 kBtu/h
No minimum efficiency requirement applies
Fan System: None
1 HVAC System 3 (Unknown) :
Heating: 1 each - Unit Heater, Electric, Capacity = 2 kBtu/h
No minimum efficiency requirement applies
Fan System: None
Section 5: Compliance Statement
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2012 IECC
requirements in COMcheck Version 3.9.4 and to comply with the mandatory requirements in the Requirements Checklist.
Name - Title Signature Date
Section 6: Post Construction Compliance Statement
q HVAC record drawings of the actual installation and performance data for each equipment provided to the owner within 90 days after
system acceptance.
q HVAC O&M documents for all mechanical equipment and system provided to the owner within 90 days after system acceptance.
q Written HVAC balancing report provided to the owner.
Project Title: FORD PARK LOWER BENCH RESTROOMS Report date: 01/07/15
Data filename: P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom 2014\Calculations\COMcheck\2015-0106 FORD
RESTROOMS.cck Page 4 of 4
The above post construction requirements have been completed.
Principal Mechanical Designer-Name Signature Date
Inspection Checklist
Requirements: 0.0% were addressed directly in the COMcheck software
COMcheck Software Version 3.9.4
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2012 IECC
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project
Data
FORD PARK LOWER BENCH RESTROOMS
P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom
2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck
Page 1 of
01/07/1Report date:
9
2012 IECC Plan Review Complies?Comments/Assumptions
C103.2
[PR1]1
Plans and/or specifications provide all
information with which compliance
can be determined for the building
envelope and document where
exceptions to the standard are
claimed.
Complies
Does Not
Not Observable
Not Applicable
C103.2
[PR2]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the mechanical
systems and equipment and
document where exceptions to the
standard are claimed. Load
calculations per acceptable
engineering standards and
handbooks.
Complies
Does Not
Not Observable
Not Applicable
C406
[PR9]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the additional energy
efficiency package options.
Complies
Does Not
Not Observable
Not Applicable
C402.3.1
[PR10]1
Vertical fenestration area <= 30
percent of the gross above-grade wall
area.
Complies
Does Not
Not Observable
Not Applicable
C402.3.1
[PR11]1
Skylight area <= 3 percent of the
gross roof area.
Complies
Does Not
Not Observable
Not Applicable
C402.3.2.
2
[PR15]1
Areas with obstructions that block
direct beam sunlight on >= 1/2 of the
roof over the enclosed area for more
than 1,500 daytime hours per year
between 8 am and 4 pm.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project
Data
FORD PARK LOWER BENCH RESTROOMS
P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom
2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck
Page 2 of
01/07/1Report date:
9
Section
#
& Req.ID
Footing / Foundation
Inspection
Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
C402.2.6
[FO3]2
Slab edge insulation R-value.R-_____
Unheated
Heated
R-_____
Unheated
Heated
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
C303.2
[FO4]2
Slab edge insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C402.2.6
[FO5]2
Slab edge insulation
depth/length. Slab insulation
extending away from building is
covered by pavement or >= 10
inches of soil.
_____ ft _____ ft Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
C403.2.7,
C408.2.8,
C404.5
[FO6]1
Exterior insulation protected
against damage, sunlight,
moisture, wind, landscaping and
equipment maintenance
activities.
Complies
Does Not
Not Observable
Not Applicable
C403.2.4.
5
[FO9]3
Freeze protection and snow/ice
melting system sensors for future
connection to controls.
Complies
Does Not
Not Observable
Not Applicable
C402.2.8
[FO12]3
Bottom surface of floor structures
incorporating radiant heating
insulated to >=R-3.5.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project
Data
FORD PARK LOWER BENCH RESTROOMS
P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom
2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck
Page 3 of
01/07/1Report date:
9
Section
#
& Req.ID
Framing / Rough-In Inspection Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
C402.4.1,
C402.4.2
[FR16]1
The building envelope contains a
continuous air barrier that is
sealed in an approved manner
and either constructed or tested
in an approved manner. Air
barrier penetrations are sealed in
an approved manner.
Complies
Does Not
Not Observable
Not Applicable
C402.4.3,
C402.4.4
[FR18]3
Factory-built fenestration and
doors are labeled as meeting air
leakage requirements.
Complies
Does Not
Not Observable
Not Applicable
C402.4.7
[FR17]3
Vestibules are installed on all
building entrances. Doors have
self-closing devices.
Complies
Does Not
Not Observable
Not Applicable
C402.3.3,
C402.3.4
[FR8]1
Vertical fenestration U-Factor.U-_____U-_____Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
C402.3.3
[FR10]1
Vertical fenestration SHGC value.SHGC:_____SHGC:_____Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
C303.1.3
[FR12]2
Fenestration products rated in
accordance with NFRC.
Complies
Does Not
Not Observable
Not Applicable
C303.1.3
[FR13]1
Fenestration products are
certified as to performance labels
or certificates provided.
Complies
Does Not
Not Observable
Not Applicable
C402.2.7
[FR14]2
U-factor of opaque doors
associated with the building
thermal envelope meets
requirements.
U-_____
Swinging
Nonswinging
U-_____
Swinging
Nonswinging
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project
Data
FORD PARK LOWER BENCH RESTROOMS
P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom
2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck
Page 4 of
01/07/1Report date:
9
Section
#
& Req.ID
Mechanical Rough-In
Inspection
Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
C403.2.3
[ME55]2
HVAC equipment efficiency
verified.
Efficiency:_____Efficiency:_____Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values.
C402.4.5.
1
[ME3]3
Stair and elevator shaft vents
have motorized dampers that
automatically close.
Complies
Does Not
Not Observable
Not Applicable
C402.4.5.
2
[ME58]3
Outdoor air and exhaust systems
have motorized dampers that
automatically shut when not in
use and meet maximum leakage
rates. Check gravity dampers
where allowed.
Complies
Does Not
Not Observable
Not Applicable
C403.2.5.
1
[ME59]1
Demand control ventilation
provided for spaces >500 ft2 and
>25 people/1000 ft2 occupant
density and served by systems
with air side economizer, auto
modulating outside air damper
control, or design airflow >3,000
cfm.
Complies
Does Not
Not Observable
Not Applicable
C403.2.7
[ME60]2
HVAC ducts and plenums
insulated. Where ducts or
plenums are installed in or under
a slab, verification may need to
occur during Foundation
Inspection.
R-_____R-_____Complies
Does Not
Not Observable
Not Applicable
C403.2.8
[ME61]2
HVAC piping insulation thickness.
Where piping is installed in or
under a slab, verification may
need to occur during Foundation
Inspection.
_____ in._____ in.Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values for HVAC System 1.
C403.2.8
[ME61]2
HVAC piping insulation thickness.
Where piping is installed in or
under a slab, verification may
need to occur during Foundation
Inspection.
_____ in._____ in.Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values for HVAC System 2.
C403.2.8
[ME61]2
HVAC piping insulation thickness.
Where piping is installed in or
under a slab, verification may
need to occur during Foundation
Inspection.
_____ in._____ in.Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values for HVAC System 3.
C403.2.8
[ME41]3
Thermally ineffective panel
surfaces of sensible heating
panels have insulation >= R-3.5.
Complies
Does Not
Not Observable
Not Applicable
C403.2.7
[ME10]2
Ducts and plenums sealed based
on static pressure and location.
Complies
Does Not
Not Observable
Not Applicable
C403.2.7.
1.3
[ME11]3
Ductwork operating >3 in. water
column requires air leakage
testing.
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values for HVAC System 1.
C403.2.7.
1.3
[ME11]3
Ductwork operating >3 in. water
column requires air leakage
testing.
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values for HVAC System 2.
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project
Data
FORD PARK LOWER BENCH RESTROOMS
P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom
2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck
Page 5 of
01/07/1Report date:
9
Section
#
& Req.ID
Mechanical Rough-In
Inspection
Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
C403.2.7.
1.3
[ME11]3
Ductwork operating >3 in. water
column requires air leakage
testing.
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values for HVAC System 3.
C408.2.2.
1
[ME53]3
Air outlets and zone terminal
devices have means for air
balancing.
Complies
Does Not
Not Observable
Not Applicable
C403.4.2
[ME66]2
VAV fan motors >=7.5 hp to be
driven by variable speed drive,
have a vane-axial fan with
variable pitch blades, or have
controls to limit fan motor
demand.
VSD
Vane axial
fan
Other
VSD
Vane axial
fan
Other
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values for HVAC System 1.
C403.4.2
[ME66]2
VAV fan motors >=7.5 hp to be
driven by variable speed drive,
have a vane-axial fan with
variable pitch blades, or have
controls to limit fan motor
demand.
VSD
Vane axial
fan
Other
VSD
Vane axial
fan
Other
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values for HVAC System 2.
C403.4.2
[ME66]2
VAV fan motors >=7.5 hp to be
driven by variable speed drive,
have a vane-axial fan with
variable pitch blades, or have
controls to limit fan motor
demand.
VSD
Vane axial
fan
Other
VSD
Vane axial
fan
Other
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list
for values for HVAC System 3.
C403.2.6
[ME57]1
Exhaust air energy recovery on
systems meeting Table C403.2.6
Complies
Does Not
Not Observable
Not Applicable
C403.2.11
[ME71]2
Unenclosed spaces that are
heated use only radiant heat.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project
Data
FORD PARK LOWER BENCH RESTROOMS
P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom
2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck
Page 6 of
01/07/1Report date:
9
Section
#
& Req.ID
Insulation Inspection Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
C402.4.1.
1
[IN1]1
All sources of air leakage in the
building thermal envelope are
sealed, caulked, gasketed,
weather stripped or wrapped with
moisture vapor-permeable
wrapping material to minimize air
leakage.
Complies
Does Not
Not Observable
Not Applicable
C402.4.2.
1
[IN2]1
Roof R-value. For some ceiling
systems, verification may need to
occur during Framing Inspection.
R-_____
Above deck
Metal
Attic
R-_____
Above deck
Metal
Attic
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
C303.2
[IN3]1
Roof insulation installed per
manufacturer’s instructions.
Blown or poured loose-fill
insulation is installed only where
the roof slope is <=3 in 12.
Complies
Does Not
Not Observable
Not Applicable
C303.2
[IN7]1
Above-grade wall insulation
installed per manufacturer’s
instructions.
Complies
Does Not
Not Observable
Not Applicable
C402.2.5
[IN8]2
Floor insulation R-value.R-_____
Mass
Steel
Wood
R-_____
Mass
Steel
Wood
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
C303.1
[IN10]2
Building envelope insulation is
labeled with R-value or insulation
certificate providing R-value and
other relevant data.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[IN14]2
Exterior insulation is protected
from damage with a protective
material. Verification for exposed
foundation insulation may need
to occur during Foundation
Inspection.
Complies
Does Not
Not Observable
Not Applicable
C402.2.1
[IN17]3
Insulation intended to meet the
roof insulation requirements
cannot be installed on top of a
suspended ceiling. Mark this
requirement compliant if
insulation is installed accordingly.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project
Data
FORD PARK LOWER BENCH RESTROOMS
P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom
2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck
Page 7 of
01/07/1Report date:
9
2012 IECC Final Inspection Complies?Comments/Assumptions
C402.4.6
[FI37]1
Weatherseals installed on all loading
dock cargo doors.
Complies
Does Not
Not Observable
Not Applicable
C403.2.4.
2
[FI47]3
Heating and cooling to each zone is
controlled by a thermostat control.
Minimum one humidity control device
per installed
humidification/dehumidification
system.
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list for values for HVAC System 1.
C403.2.4.
2
[FI47]3
Heating and cooling to each zone is
controlled by a thermostat control.
Minimum one humidity control device
per installed
humidification/dehumidification
system.
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list for values for HVAC System 2.
C403.2.4.
2
[FI47]3
Heating and cooling to each zone is
controlled by a thermostat control.
Minimum one humidity control device
per installed
humidification/dehumidification
system.
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list for values for HVAC System 3.
C403.2.4.
2
[FI38]3
Thermostatic controls have a 5 °F
deadband.
Complies
Does Not
Not Observable
Not Applicable
C403.2.4.
2
[FI20]3
Temperature controls have setpoint
overlap restrictions.
Complies
Does Not
Not Observable
Not Applicable
C403.2.4.
3
[FI39]3
Each zone equipped with setback
controls using automatic time clock or
programmable control system.
Complies
Does Not
Not Observable
Not Applicable
C403.2.4.
3
[FI40]3
Automatic Controls: Setback to 55°F
(heat) and 85°F (cool); 7-day clock, 2-
hour occupant override, 10-hour
backup
Complies
Does Not
Not Observable
Not Applicable
C408.2.5.
1
[FI7]3
Furnished HVAC as-built drawings
submitted within 90 days of system
acceptance.
Complies
Does Not
Not Observable
Not Applicable
C303.3,C4
08.2.5.2
[FI8]3
Furnished O&M manuals for HVAC
systems within 90 days of system
acceptance.
Complies
Does Not
Not Observable
Not Applicable
C408.2.5.
3
[FI43]1
An air and/or hydronic system
balancing report is provided for HVAC
systems.
Complies
Does Not
Not Observable
Not Applicable
C408.2.3.
2
[FI10]1
HVAC control systems have been
tested to ensure proper operation,
calibration and adjustment of controls.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project
Data
FORD PARK LOWER BENCH RESTROOMS
P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom
2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck
Page 8 of
01/07/1Report date:
9
2012 IECC Final Inspection Complies?Comments/Assumptions
C402.4.8
[FI26]3
Recessed luminaires in thermal
envelope to limit infiltration and be IC
rated and labeled. Seal between
interior finish and luminaire housing.
Complies
Does Not
Not Observable
Not Applicable
C403.2.2
[FI27]3
HVAC systems and equipment
capacity does not exceed calculated
loads.
Complies
Does Not
Not Observable
Not Applicable
C408.2.1
[FI28]1
Commissioning plan developed by
registered design professional or
approved agency.
Complies
Does Not
Not Observable
Not Applicable
C408.2.4
[FI29]1
Preliminary commissioning report
completed and certified by registered
design professional or approved
agency.
Complies
Does Not
Not Observable
Not Applicable
C408.2.5.
4
[FI30]1
Final commissioning report due to
building owner within 90 days of
receipt of certificate of occupancy.
Complies
Does Not
Not Observable
Not Applicable
C408.2.3.
1
[FI31]1
HVAC equipment has been tested to
ensure proper operation.
Complies
Does Not
Not Observable
Not Applicable
C406
[FI34]1
Efficient HVAC performance, efficient
lighting system, or on-site supply of
renewable energy consistent with
what is shown the approved plans.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project
Data
FORD PARK LOWER BENCH RESTROOMS
P:\Current Projects\14098.00 - Ford Park Lower Bench Restroom
2014\Calculations\COMcheck\2015-0106 FORD RESTROOMS.cck
Page 9 of 9