HomeMy WebLinkAboutA1 - STAIR WELL STORAGE.pdf14'-9"
7'-6"
7'-3"
12'-10 1/2"
2"
5'-3"
7'-8"
1'-0" -0"
1'-0"
MB 14'-9"
7'-6"
7'-3"
12'-10 1/2"
2"
5'-3"
7'-8"
1'-0"
-0"
1'-0"
MB
EXISTING
DEMO
PROPOSED
WALL TYPES
EXISTING
JANITOR'S
CLOSET
3
A1
NEW STORAGE
SPACE UNDER
STAIRS
NEW OPENING TO
ACCESS NEW
STORAGE SPACE
UNDERSTAIRS
EXISTING
JANITOR'S
CLOSET
NEW TROPHY
CASEMENTS
FIRE RATED ASSEMBLY
TO COVER NEW TROPHY
CASEMENTS
FIRE CAULK AT
ALL SEEMS, TYP.
(2) LAYERS 5/8" TYPE X
GYPSUM WALLBOARD
EXISTING WALLS OR
ASSEMBLIES TO BE FIRE
PROTECTED WITH HAT
CHANNELS, GYPSUM
BOARD AND FIRE CAULK.
7/8" HAT CHANNEL @
16"-0" O.C. MIN., TYP.
(2) LAYERS 5/8" TYPE X
GYPSUM WALLBOARD
OVER 7/8" HAT CHANNEL
NOTE: (2) 5/8" TYPE X GYPSUM WALLBOARD OVER 7/8"
HAT CHANNEL ASSEMBLY TO COVER AND PROTECT ALL
EXISTING WALLS AND BOTTOM OF STAIR ASSEMBLY.
(2) LAYERS 5/8" TYPE
X GYPSUM
WALLBOARD OVER
7/8" HAT CHANNEL,
HAT CHANNEL @ 16"
O.C., TYP.
NEW STORAGE
SPACE UNDER
STAIRS
FIRE CAULK ALL
JOINTS AND SEEMS,
TYP.
N
KEY PLAN
MAIN FLOOR
PROJECT LOCATION
VMS - Code, Building Type and Occupancy
Code - 2012 IBC
Construction Type - II-B
Occupancy - E (EDUCATION)
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
3000 BOOTH FALLS RD
VAIL, CO 81657
A1
STAIR WELL
STORAGE
VMS - MINOR INTERIOR MOD.
Project #1479
1/22/15
PERMIT SET
1/4" = 1'-0" A1
1A
STAIR 005 - MAIN LEVEL EXISTING
1/4" = 1'-0" A1
2A
STAIR 005 - MAIN LEVEL PROPOSED
3" = 1'-0"
WALL TYPE 1HC
1/2" = 1'-0"
A1
3
STAIR SECTION
02/09/15