HomeMy WebLinkAboutLoads Calcs.pdf Page 1 of 4 1/27/2015 Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233/info@activeenergies.com) Site: Corrigan Residence 2722 Cortina Lane Vail, CO 81657 All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F Panel Arrangement: Panel Arrangement: 5 rows of 8 panels between the snow fences, oriented in the portrait position, mounted flush on the south facing metal roof A: PV AC Disconnect B: Meter A B PV Panels: 40 Phono PS250P-20/U Inverters: 40 Enphase M-215 240v Page 2 of 4 1/27/2015 Calculations 10.0kW System Size (STC) 40 Phono Solar PS250P-20/U solar panels @ 250 watts 40 Enphase M-215 240 micro-inverters –3 branch of 8/16/16 units each Fixed array tilt angle: 11.77º Array azimuth: 180° (where 180º is south) Estimated annual power production: 13,603kWh Maximum PV System Voltage: 690.7 Voc= 37.8V/module 37.8V x 1 module = 37.8V Temperature correction factor 690.7(A) STC = 25°C, Temperature Coefficient (Voc) = -0.31%/°K (298°K- 233°k) = 65°K 37.8V + (-65°K x (-0.31%/°K x 37.8V) x 1 module) = 45.4V Temperature correction factor Table 690.7 For -40ºF use 1.25 37.8V x 1.25 = 47.3V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 8.7A 8.7A x 1.25 = 10.9A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) 10.9A x 1 strings = 10.9A Inverter Output Circuit Current: 690.8 (A)(3) .9A @ 240V John Wiles, “Photovoltaic Power Systems and the National Electrical Code: Suggested Practices”, 2005, pp. E1-E25. Page 3 of 4 1/27/2015 Conductor Sizing Pass Thru Box on Roof to PV Sub-Panel (for a 16 panel circuit): Nameplate maximum continuous output current: .9A Maximum Output Power 215 Watts AC 215W ÷ 240 V = .9A .9A x 16 inverters = 14.4A per branch 14.4A x 125% = 18A #10 NM-B Table 310.16 35A (75ºC column, see note 240.4(D)) Conduit fill adjustment Table 310.15 (B)(2)(a) No Conduit Fill Adjustment Temperature correction factor Table 310.16 No Temperature Correction PV Sub-Panel to Disconnect to Service Panel (for a 40 panels): .9A x 40 inverters = 36A per branch 36A x 125% = 45A #8 NM-B Table 310.16 50A (75ºC column) Conduit fill adjustment Table 310.15 (B)(2)(a) No Conduit Fill Adjustment Temperature correction factor Table 310.16 No Temperature Correction Overcurrent Protection 20A two pole per Enphase circuit Per Manufacturer Specification 50A two pole backfeed breaker