HomeMy WebLinkAboutB15-0031 E-301.pdfELECTRICAL / TELEPHONE LEGEND +XX ELECTRICAL PANEL MOTOR STARTER DISCONNECT-RATED FOR USE DISPOSER WITH SWITCH S THERMAL OVERLOAD SWITCH STO TRANSFORMER BLDG. STD. WALL MOUNTED DUPLEX ELECTRICAL OUTLET BLDG. STD. WALL MOUNTED FOURPLEX ELECTRICAL OUTLET WALL MOUNTED SPECIAL ELECTRIC OUTLET BLDG. STD. WALL MOUNTED TELEPHONE AND DATA OUTLET BLDG. STD. FLUSH MOUNTED ELECTRICAL/ DATA DENOTES DEDICATED OUTLET SPECIAL MOUNTING HEIGHT INDICATION FOR WALL OUTLETS BLDG. STD. SINGLE POLE LIGHT SWITCH BLDG. STD. THERMOSTAT BLDG. STD. J BOX BLDG. STD. COVER PLATE BLDG. STD. POWER POLE CABLE TV CONNECTION (BY TENANT) BLDG. STD. WALL MOUNTED TELEPHONE OUTLET S DEMOLITION CIRCUITRY EXISTING CIRCUITRY NEW CIRCUITRY NOTES: DASHED FIXTURES INDICATES EXISTING TO BE REMOVE / DEMOLISHED. E = EXISTING R = RELOCATED N = NEW GENERAL NOTES - POWER: REUSE EXISTING DIMMING CIRCUITRY AND CONTROLS MADE AVAILABLE. RELOCATE EXISTING EQUIPMENT / POWER FROM NICHE TO NEW WALL LOCATION. COORDINATE EXACT LOCATIONS WITH ARCHITECT PRIOR TO PRICING AND INSTALLATION. RELOCATE EXISTING BAR EQUIPMENT / POWER. COORDINATE EXACT NEW LOCATIONS WITH ARCHITECT PRIOR TO PRICING AND INSTALLATION. RELOCATE EXISTING FIRE PLACE SWITCH AS DIRECTED BY ARCHITECT AND INTERIOR DESIGNER PRIOR TO PRICING AND INSTALLATION. REUSE EXISTING CIRCUITRY MADE AVAILABLE THROUGH DEMOLITION. PROVIDE FLOOR MOUNTED POWER / DATA OUTLET. COORDINATE EXACT LOCATION AND SPECIFICATION WITH ARCHITECT. CONNECT TO EXISTING 120V. CIRCUITRY AS SHOWN. ENSURE CIRCUIT CONTINUITY. 1 2 ELECTRICAL DETAIL NOTES - POWER 4 5 1. ALL DASHED ELECTRICAL DEVICES ARE TO BE DEMOLISHED. REMOVE ALL CIRCUITRY BACK TO PANEL. REMOVE ALL UNUSED CONDUITS AND JUNCTION BOXES. 2. ALL RECEPTACLES WITHIN 6'-0" FROM SINK SHALL BE GFI PROTECTED AND READILY ACCESSIBLE PER NEC 210.8 3. UNLESS DENOTED WITH "N" ALL ELECTRICAL SHOWN IS EXISTING TO REMAIN. 4. ALL COMPUTER AND TELEPHONE CABLING SHALL BE PULLED BY TENANTS REPRESENTATIVE. 5. CIRCUIT NUMBERS SHOWN ARE FOR REFERENCE ONLY AND SHOW DESIGN INTENT. ACTUAL AVAILABLE CIRCUIT NUMBERS MAY DIFFER. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY. 6. ENSURE CIRCUIT CONTINUITY TO RECEPTACLES THAT ARE EXISTING TO REMAIN AND MAY BE AFFECTED BY DEMOLITION / REMODEL WORK. 7. COORDINATE ALL FIRE ALARM REQUIREMENTS WITH FIRE ALARM CONTRACTOR. 8. REFER TO MECHANICAL DRAWINGS FOR ANY ADDITIONAL INFORMATION AND ELECTRICAL REQUIREMENTS REGARDING ELECTRICAL EQUIPMENT. 8. PROVIDE TYPEWRITTEN UPDATED PANEL DOOR DIRECTORIES FOR ALL AFFECTED PANELS REFLECTING ALL CIRCUITS WITH THEIR ACCURATE DESTINATIONS PER N.E.C. 408.4. TURN OFF ALL UNUSED BREAKERS AND INDICATE "SPARE" IN PANEL INDEX. 9. PROVIDE STICKERS ON ALL RECEPTACLE COVERPLATES INDICATING PANEL AND CIRCUIT NUMBER INFORMATION IN TENANT SUITE. 3 6 H H P POS POS ENTRY - VESTIBULE - GALLERY EAST - GALLERY WEST - LOUNGE - BAR - LIBRARY - LANDING - E E E E E E E E E E E E E E E E E E E E R E E E R E E E E E E E E N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 55" TV NOTE: NEW FLOOR RECESSED DIMMED RECEPTACLES. VERIFY EXACT LOCATION WITH ARCHITECT / INTERIOR DESIGNER. REUSE EXISTING CHANNEL IF AVAILABLE. X-RAY SLAB PRIOR TO CHANNELING. (TYPICAL OF ALL) 55" TV 55" TV 55" TV (9)55" TVs 1 (LB6) 4 4 4 4 1 (E7) E E 4 4 N N 1 (L10) NOTE: NEW FLOOR RECESSED DIMMED RECEPTACLES. VERIFY EXACT LOCATION WITH ARCHITECT / INTERIOR DESIGNER. REUSE EXISTING CHANNEL IF AVAILABLE. X-RAY SLAB PRIOR TO CHANNELING. (TYPICAL OF ALL) 2 2 3 N N P.O.S. P.O.S. VERIFY EXACT LOCATION AND DEVICE MOUNTING HEIGHT WITH ARCHITECT. 4 E 5 5 5 5 E E 6 3/4" C. 3/4" C. N 6 ART (EXISTING) ART (EXISTING) ART (EXISTING) ART (EXISTING) 4 4 4 4 4 4 MIRROR (EXISTING) ART (EXISTING) ART (EXISTING) 1 E-401 SEE ENLARGED PLAN N N N 5 5 ISSUE DATE JMM CHK BY: SCALE: SHEET: JOB #: DRW BY: TITLE: DATE: COMMENT AS NOTED TNS SEAL & SIGNATURE: 14-37 1 FOUR SEASONS RESORT & RESIDENCES VAIL, CO FIFTH FLOOR REMODEL FOR PERMIT 2/16/15 CLIENT: Four Seasons Resort & Residences One Vail Road VAIL, CO 81657 ARCHITECT: Creative Design Associates 434 BROADWAY, 5TH FLOOR NEW YORK, NY 10013 t 212-748-8900 WESTERN US 4700 E BROMLEY LN, SUITE 105 BRIGHTON, CO 80601 t 646-747-2171 c 917-756-0057 dsorenson@ralcompanies.com INTERIOR DESIGN: Meyer Davis Studio 180 VARICK STREET #404 NEW YORK, NY 10014 t 212-627-5574 graydavis@meyerdavis.com ELECTRICAL ENGINEER: C3S Incorporated 3212 WEST 45TH AVENUE DENVER, CO 80211 t 303-480-5144 theresa@c3sengineeringinc.com MECHANICAL ENGINEER: MDP Engineering Group 1800 Glenarm Place, Suite 800 DENVER, CO 80202 t 303-389-0095 rloomer@mdpeg.com LIGHTING DESIGN: Bouyea & Associates 5 Green Hill Road 2nd & 3rd Floors Washington Depot, CT 06794 t 860-868-4500 bbouyea@bouyea.com FOODSERVICE CONSULTANT: Ricca Design Studios 2 Northside Piers, Suite 8C Brooklyn, NY 11249 t 303-221-0500 dchislett@ricca.com 2/16/215 POWER PLAN E-301 5TH FLOOR LOBBY AREA POWER PLAN 1 C3S Incorporated 03/17/15