HomeMy WebLinkAboutB15-0031 E-301.pdfELECTRICAL / TELEPHONE LEGEND
+XX
ELECTRICAL PANEL
MOTOR
STARTER
DISCONNECT-RATED FOR USE
DISPOSER WITH SWITCH
S
THERMAL OVERLOAD SWITCH
STO
TRANSFORMER
BLDG. STD. WALL MOUNTED DUPLEX ELECTRICAL OUTLET
BLDG. STD. WALL MOUNTED FOURPLEX ELECTRICAL OUTLET
WALL MOUNTED SPECIAL ELECTRIC OUTLET
BLDG. STD. WALL MOUNTED TELEPHONE AND DATA OUTLET
BLDG. STD. FLUSH MOUNTED ELECTRICAL/ DATA
DENOTES DEDICATED OUTLET
SPECIAL MOUNTING HEIGHT INDICATION FOR WALL OUTLETS
BLDG. STD. SINGLE POLE LIGHT SWITCH
BLDG. STD. THERMOSTAT
BLDG. STD. J BOX
BLDG. STD. COVER PLATE
BLDG. STD. POWER POLE
CABLE TV CONNECTION (BY TENANT)
BLDG. STD. WALL MOUNTED TELEPHONE OUTLET
S
DEMOLITION CIRCUITRY
EXISTING CIRCUITRY
NEW CIRCUITRY
NOTES:
DASHED FIXTURES INDICATES EXISTING TO BE REMOVE / DEMOLISHED.
E = EXISTING R = RELOCATED N = NEW
GENERAL NOTES - POWER:
REUSE EXISTING DIMMING CIRCUITRY AND CONTROLS MADE
AVAILABLE.
RELOCATE EXISTING EQUIPMENT / POWER FROM NICHE TO NEW WALL
LOCATION. COORDINATE EXACT LOCATIONS WITH ARCHITECT PRIOR TO
PRICING AND INSTALLATION.
RELOCATE EXISTING BAR EQUIPMENT / POWER. COORDINATE EXACT
NEW LOCATIONS WITH ARCHITECT PRIOR TO PRICING AND
INSTALLATION.
RELOCATE EXISTING FIRE PLACE SWITCH AS DIRECTED BY ARCHITECT
AND INTERIOR DESIGNER PRIOR TO PRICING AND INSTALLATION.
REUSE EXISTING CIRCUITRY MADE AVAILABLE THROUGH DEMOLITION.
PROVIDE FLOOR MOUNTED POWER / DATA OUTLET. COORDINATE
EXACT LOCATION AND SPECIFICATION WITH ARCHITECT. CONNECT TO
EXISTING 120V. CIRCUITRY AS SHOWN. ENSURE CIRCUIT CONTINUITY.
1
2
ELECTRICAL DETAIL NOTES - POWER
4
5
1. ALL DASHED ELECTRICAL DEVICES ARE TO BE DEMOLISHED. REMOVE
ALL CIRCUITRY BACK TO PANEL. REMOVE ALL UNUSED CONDUITS AND
JUNCTION BOXES.
2. ALL RECEPTACLES WITHIN 6'-0" FROM SINK SHALL BE GFI PROTECTED
AND READILY ACCESSIBLE PER NEC 210.8
3. UNLESS DENOTED WITH "N" ALL ELECTRICAL SHOWN IS EXISTING TO
REMAIN.
4. ALL COMPUTER AND TELEPHONE CABLING SHALL BE PULLED BY
TENANTS REPRESENTATIVE.
5. CIRCUIT NUMBERS SHOWN ARE FOR REFERENCE ONLY AND SHOW
DESIGN INTENT. ACTUAL AVAILABLE CIRCUIT NUMBERS MAY DIFFER.
ELECTRICAL CONTRACTOR SHALL FIELD VERIFY.
6. ENSURE CIRCUIT CONTINUITY TO RECEPTACLES THAT ARE EXISTING TO
REMAIN AND MAY BE AFFECTED BY DEMOLITION / REMODEL WORK.
7. COORDINATE ALL FIRE ALARM REQUIREMENTS WITH FIRE ALARM
CONTRACTOR.
8. REFER TO MECHANICAL DRAWINGS FOR ANY ADDITIONAL
INFORMATION AND ELECTRICAL REQUIREMENTS REGARDING
ELECTRICAL EQUIPMENT.
8. PROVIDE TYPEWRITTEN UPDATED PANEL DOOR DIRECTORIES FOR ALL
AFFECTED PANELS REFLECTING ALL CIRCUITS WITH THEIR ACCURATE
DESTINATIONS PER N.E.C. 408.4. TURN OFF ALL UNUSED BREAKERS
AND INDICATE "SPARE" IN PANEL INDEX.
9. PROVIDE STICKERS ON ALL RECEPTACLE COVERPLATES INDICATING
PANEL AND CIRCUIT NUMBER INFORMATION IN TENANT SUITE.
3
6
H H
P
POS
POS
ENTRY
-
VESTIBULE
-
GALLERY EAST
-
GALLERY WEST
-
LOUNGE
-
BAR
- LIBRARY
-
LANDING
-
E E
E
E
E E
E E
E
E
E
E
E E
E
E
E
E
E
E
R
E
E
E
R
E E
E E
E
E
E
E N
N
N
N N
N
N
N
N
N N
N
N
N
N
N
N
N
N
N N
N
N
N
N
N
N
N
N
N
55" TV
NOTE: NEW FLOOR
RECESSED
DIMMED RECEPTACLES.
VERIFY EXACT LOCATION
WITH ARCHITECT /
INTERIOR DESIGNER.
REUSE EXISTING
CHANNEL IF AVAILABLE.
X-RAY SLAB PRIOR TO
CHANNELING.
(TYPICAL OF ALL)
55" TV
55" TV
55" TV
(9)55" TVs
1 (LB6)
4
4
4
4
1
(E7)
E
E
4
4
N
N
1 (L10)
NOTE: NEW FLOOR
RECESSED
DIMMED RECEPTACLES.
VERIFY EXACT LOCATION
WITH ARCHITECT /
INTERIOR DESIGNER.
REUSE EXISTING
CHANNEL IF AVAILABLE.
X-RAY SLAB PRIOR TO
CHANNELING.
(TYPICAL OF ALL)
2
2
3
N
N
P.O.S.
P.O.S.
VERIFY EXACT LOCATION
AND DEVICE MOUNTING
HEIGHT WITH ARCHITECT.
4
E
5
5
5
5
E E
6
3/4" C. 3/4" C.
N
6
ART
(EXISTING)
ART
(EXISTING)
ART
(EXISTING)
ART
(EXISTING)
4
4
4
4
4 4
MIRROR
(EXISTING)
ART
(EXISTING)
ART
(EXISTING)
1
E-401
SEE ENLARGED PLAN
N N
N
5
5
ISSUE DATE
JMM
CHK BY:
SCALE:
SHEET:
JOB #:
DRW BY:
TITLE:
DATE:
COMMENT
AS NOTED
TNS
SEAL & SIGNATURE:
14-37
1
FOUR SEASONS
RESORT & RESIDENCES
VAIL, CO
FIFTH FLOOR
REMODEL
FOR PERMIT
2/16/15
CLIENT:
Four Seasons Resort & Residences
One Vail Road
VAIL, CO 81657
ARCHITECT:
Creative Design Associates
434 BROADWAY, 5TH FLOOR
NEW YORK, NY 10013
t 212-748-8900
WESTERN US
4700 E BROMLEY LN, SUITE 105
BRIGHTON, CO 80601
t 646-747-2171
c 917-756-0057
dsorenson@ralcompanies.com
INTERIOR DESIGN:
Meyer Davis Studio
180 VARICK STREET #404
NEW YORK, NY 10014
t 212-627-5574
graydavis@meyerdavis.com
ELECTRICAL ENGINEER:
C3S Incorporated
3212 WEST 45TH AVENUE
DENVER, CO 80211
t 303-480-5144
theresa@c3sengineeringinc.com
MECHANICAL ENGINEER:
MDP Engineering Group
1800 Glenarm Place, Suite 800
DENVER, CO 80202
t 303-389-0095
rloomer@mdpeg.com
LIGHTING DESIGN:
Bouyea & Associates
5 Green Hill Road
2nd & 3rd Floors
Washington Depot, CT 06794
t 860-868-4500
bbouyea@bouyea.com
FOODSERVICE CONSULTANT:
Ricca Design Studios
2 Northside Piers, Suite 8C
Brooklyn, NY 11249
t 303-221-0500
dchislett@ricca.com
2/16/215
POWER PLAN
E-301
5TH FLOOR LOBBY AREA POWER PLAN
1 C3S
Incorporated
03/17/15