HomeMy WebLinkAboutA4-03.pdfELEV. STAIR STAIR STEAM SHOWER SAUNA MEN'S LOCKER ROOM WOMEN'S LOCKER ROOM NEW SAUNA STEAM SHOWER BOOT DRYING ROOM OVERHEAD ROLLING DOOR UNIT B-18 3' - 0 1/2" 1' - 5 1/8" SPA ROOM EXISTING W6x15.5 - INSTALL INDIVIDUAL 1HR FIRE PROTECTION PER IBC TABLE 721.1(1) SEC 1-7.1 - APPLY CEMENT BOARD FOR TILE INSTALLATION (SEE SHEET A7.00) NEW GLASS WALL 18" - 6' FROSTED 9' - 4 3/4" 8 5/8" 6 3/4" 4' - 2 5/8" 5 1/2" 16' - 11 1/8" 2' - 3 1/4" 7 1/4" NEW FROSTED GLASS WALL 1 A5.12 48' - 8" 5 1/2" 4' - 6" 3 1/2" 1' - 0" 3 1/2" 10' - 9 3/8" 3 1/2" 8' - 1 1/4" 5 1/2" 4' - 9 1/4" 5 1/2" 4' - 11 5/8" 5 1/2" 3' - 11 3/4" 3 1/2" 7' - 6 7/8" 10' - 7 3/8" 8" 9' - 0 7/8" 9' - 4 3/4" 6 3/4" 3' - 0 3/4" 0" 4" 45' - 5 1/8" 25' - 0 3/4" 1"1' - 9 1/2" 4' - 3" 1' - 0" 3 1/2" 4 1/2" 3 1/2" 3 1/2" 3' - 0 7/8" 3 1/2" 5' - 0 1/4" 3 1/2" 3 1/2" 3 1/2" 3' - 11 1/4" 3 1/2" 3' - 8 1/2" 3 1/2" 3 1/2" 3 1/2"1' - 6" 5' - 7 3/4" 6' - 11 1/4" 3 1/2" 3' - 7 3/4" 9 3/4" 9' - 8 5/8" 4 1/2" 3' - 3 1/2" 3 1/2" 3 1/2" 2' - 11 5/8" 3' - 3 5/8" 2' - 9 1/4" 3 1/2" 10 1/2" 1' - 6" 1' - 6" 1' - 3 1/4" 1' - 3" 1' - 6" 1' - 6" 11 3/8" 9' - 6 3/8" 2' - 8" 7 1/4" 3 1/2" 4' - 11 5/8" 3 1/2" 8" 4 3/4" 1 1/4" 1' - 4 1/4" 3/8" 2' - 10 7/8" 2' - 3 1/4" 4' - 11 1/4" 1' - 1 1/2" 3' - 10 1/2" 1' - 0 3/8" 6' - 2"3 1/2"3 1/2"5' - 2 7/8" 3 1/2"7' - 2 5/8"3/8"14' - 10 3/8" 22' - 6 7/8" 1' - 8 3/4" 9"2' - 6"3 1/2" 6' - 5 5/8"3' - 9 3/4"5 1/2" 10' - 0 5/8" 2X 1X 10X 11X 6X 7X 4X 12X 13X 5' - 4 1/4" 3' - 2 1/8" 5' - 4 1/2" 2' - 0" 1' - 10" 3X 8X 135.00° 9X 3' - 1" 3' - 0 7/8" 4' - 0" 2' - 0 5/8" 3 1/2" 3' - 7 3/4" HAND HELD SHOWER FIXTURE HAND HELD SHOWER FIXTURE OVER FLOW DRAIN GENERAL NOTES REGARDING SAUNAS: "The Northwoods Condominium Association has an interim plan to provide accessible sauna facilities until accessible saunas are provided within Northwoods Condominium. Please contact the Building Management (970) 476 3486 for further information." GENERAL NOTES REGARDING CONSTRUCTION COST: Construction Cost of Amenities remodel: $ 788,000 Improvements made to accommodate accessibility: Glass partitions to improve circulation $ 50,000 Reframing walls to increase clearances $ 40,000 Altering steam room benches for shower access $ 30,000 Adding accessible hand shower in steam room $ 6,000 Move plumbing for ADA toilet $ 15,000 Remove curbs at showers $ 5,000 ADA lifts for pool $ 15,000 Total expenditure to increase accessibility: $ 158,000 (20% of construction cost) 4' - 0" 3' - 0" EXISTING WATER FOUNTAIN TO REMAIN ADA SHOWER CLEARANCE ADA SHOWERCLEARANCE4' - 0" 3' - 0" 135.00° 1' - 6" 6' - 3 1/2" 19' - 1 1/2" 25' - 3" 1' - 2 3/4" 3' - 8" 3' - 2" 3' - 9" 1' - 6" T.O. BENCH 18" EQ 1' - 6" T.O. BENCH 3' - 0" T.O. BENCH 2 WALL MOUNTED SHOWER BENCHES FUR OUT WALL TO ALIGN SURFACES 6' - 7 1/4" 3 1/8" 24 1/8" 10" 8" EQUAL 16 3/4" 1' - 6" 3' - 0" UPPER SAUNA BENCH LOWER SAUNA BENCH STAGGERED MS WALL TO MATCH WIDTH OF EXISTING W/ FULL BATT INSL. EXISTING CMU WALL, TO REMAIN 1 HOUR RATED ASSEMBLY 2 HOUR RATED ASSEMBLY 1.5 HOUR RATED DOOR W/ MAGNETIC HOLD OPEN NON RATED DOOR W/ ADA PUSH BUTTON OPENER ALIGN STOREFRONT W/ O.F. OF FOUNDATION WALL MS WALL W/ 8" CLEAR WIDTH MIN. FOR DUCT CLEAR MIN. 40" VERIFY CLEARANCE 1' - 6" 14X EXISTING WATER FOUNTAIN TO REMAIN 1' - 6" 3' - 0" UPPER SAUNA BENCH LOWER SAUNA BENCH 1' - 6" 1' - 6" 5X 2X 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 600 Vail Valley Drive Vail, Colorado 81657 A4.03 BLDG B ENLARGED 2ND FLOOR Northwoods Renaissance PROJECT # 1482 ASI #2 - 09.03.15 08/20/15 PERMIT SET 3/8" = 1'-0" A4.03 1 ENLARGED SECOND FLOOR 2 09/30/15