C.
B W-2SM
W-1SM
W-1SM W-1SM
W-1SM
W-1SM
FITNESS AREA
EXISTING CORRIDOR EXISTING CORRIDOR
1A
A5.11
2A
A5.11
CORRIDOR SIDE UNIT SIDE
EXISTING CORRIDOR WALL
CAREFULLY CUT AND REMOVE
GYP CEILING FROM ADJACENT
WALL SUFFICIENT TO INSTALL
2 LAYERS 5/8" GYP
2 NEW LAYERS 5/8" GYP
EXISTING METAL
DECKING ABOVE
FIBERGLASS BATT INSULATION
TO STEEL DECK ABOVE
NOTE: EXISTING GYP @ CORRIDOR WALL
TO REMAIN, DO NOT DISTURB OR DAMAGE
CORRIDOR WALL FINISHES
REINSTALL GYP CEILING &
FINISH TO MATCH EXISTING
CORRIDOR CEILING
ACOUSTICAL JOINT CAULK
EXISTING UNIT
DO NOT DISTURB
MIN. IF POSSIBLE
1' - 0"
CORRIDOR SIDE
FITNESS SIDE
EXISTING CORRIDOR WALL
EXISTING METAL
DECKING ABOVE
EXISTING
CORRIDOR DO
NOT DISTURB
NEW FULL HEIGHT
BATT INSULATION
EXISTING GYP.
EXISTING GYP. CEILING
NEW 3 LAYERS 5/8" GYP
PROPOSED: REMOVE EXISTING WALL & CEILING AS
NEED TO INSTALL BATT INSULATION. FILL STUD
CAVITY WITH FULL HEIGHT UNFACED FIBER GLASS
INSULATION.
INSTALL 3 LAYERS OF 5/8" TYPE "X" GYP. SCRIBE
GYP BOARD TO PROFILE OF METAL DECK TO
MAINTAIN TO A 3/8" MAXIMUM JOINT.
SEAL ALL OPENINGS WITH ACOUSTICAL SEALANT AT
FLOOR AND HEAD ( FIRE RATED SEALANT IF
NESSESARY ), STAGGER SEAMS BETWEEN GYP.
LAYERS.
EXISTING GYP. CEILING
TO BE REMOVED
ACCOUSTICAL JOINT
CAULK
ACCOUSTICAL JOINT
CAULK
10
10
11
11
12
12
K
H
F
D
D
C
F.
E
E
13
13
14
14
15
15
C.
W-2SM
2A
A5.11
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
600 Vail Valley Drive
Vail, Colorado 81657
A5.11
ACOUSTICAL
MITIGATION
Northwoods Renaissance
PROJECT # 1022
05/18/15
1/8" = 1'-0"
A5.11
3 SECOND FLOOR - SOUND MITIGATION
1 1/2" = 1'-0"
A5.11
2A W1-2SM - WALL ASSEMBLY @ CORRIDORS
1 1/2" = 1'-0" A5.11
1A W1-1SM - WALL ASSEMBLY @ FITNESS AREA
1/8" = 1'-0" A5.11
4 FIRST FLOOR - SOUND MITIGATION
Future Fitness?
If this is Future Fitness,
use a 2x2 layer wall or
W1-1SM at a minimum.
Upgrade other unit walls
to W1-2SM if necessary.
SMW Comments
5/22/2015
Is this layer already
there in the existing
condition? If it isn't, it
should be added to
extend the corridor side
of the drywall to
structure & seal.
09/30/15