HomeMy WebLinkAboutA6-00.pdfNOTES: 1. FIELD VERIFY ALL DIMENSIONS STYLE A FRAMELESS GLASS T.O. DOORS 7' - 2"+/- 8'-0", V.I.F. CEILING HEIGHT GLASS TRANSOM ABOVE TO MATCH DOOR OPEN ABOVE 7' - 0" 2" 7' - 2" STYLE C FRAMELESS GLASS @ SHOWER OR SAUNA 1' - 0" 6' - 2" OPEN ABOVE STYLE B FRAMELESS GLASS @ WATER CLOSETS T.O. DOORS 7' - 2" +/- 8'-0", V.I.F. CEILING HEIGHT STYLE D FRAMELESS GLASS @ ENTRY +/- 8'-0", V.I.F. CEILING HEIGHT +/- 8'-0", V.I.F. CEILING HEIGHT LOCKER ENTRY DOOR, FULL HEIGHT FIELD VERIFY FINISHED CEILING HEIGHT 2" 7' - 10" NOTES: 1. FIELD VERIFY ALL DIMENSIONS FIXED FIRE RATED PELLA DOUBLE HUNG 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 600 Vail Valley Drive Vail, Colorado 81657 A6.00 DOOR & WINDOW SCHEDULES Northwoods Renaissance PROJECT # 1482 ASI #2 - 09.03.15 08/20/15 PERMIT SET BLDG B AMENITIES - WINDOW SCHEDULE MARK Construction Type LOCATION WIDTH HEIGHT HEAD HEIGHT DESCRIPTION U-VALUE 1.1 PELLA - DOUBLE HUNG OFFICE 3' - 0" 4' - 8" 7' - 7" VERIFY DIMENSIONS IN FIELD .35 1.2 PELLA - DOUBLE HUNG OFFICE 3' - 0" 4' - 8" 7' - 7" VERIFY DIMENSIONS IN FIELD .35 1.4 PELLA - FIXED SECOND FLOOR - BOOT ROOM 3' - 0" 5' - 6" 7' - 6" SPANDREL GLASS .35 1.5 PELLA - FIXED SECOND FLOOR - BOOT ROOM 3' - 0" 5' - 6" 7' - 6" SPANDREL GLASS .35 1.7 PELLA - FIXED THIRD FLOOR - STAIR WELL 3' - 0" 5' - 6" 12' - 0" .35 1.8 PELLA - FIXED THIRD FLOOR - STAIR WELL 3' - 0" 5' - 6" 12' - 0" .35 1.9 PELLA - FIXED THIRD FLOOR - STAIR WELL 3' - 0" 5' - 6" 12' - 0" .35 DOOR SCHEDULE - INTERIOR MARK FAMILY TYPE STYLE LEVEL HEAD HEIGHT SILL HEIGHT HEIGHT WIDTH THRESHOLD CONDITION TRANSON TYPE 1X Frameless Glass Door Entry 3'-0" x 8'-0" D PROPOSED SECOND FLOOR 8' - 0" 0' - 2" 7' - 10" 3' - 0" 2" FROM FINISHED FLOOR NONE 2X Frameless Glass Door Entry 3'-0" x 8'-0" D PROPOSED SECOND FLOOR 8' - 0" 0' - 2" 7' - 10" 3' - 0" 2" FROM FINISHED FLOOR NONE 3X Frameless Glass Door WC 3'0" x 6'-2" WATER CLOSET B PROPOSED SECOND FLOOR 7' - 2" 1' - 0" 6' - 2" 3' - 0" 12" FROM FINISHED FLOOR OPEN 4X Frameless Glass Door Shower 3'0" x 7'-0" A PROPOSED SECOND FLOOR 7' - 2" 0' - 2" 7' - 0" 3' - 0" 2" FROM FINISHED FLOOR OPEN 5X Frameless Glass Door Shower 2'-0" x 7'-0" A PROPOSED SECOND FLOOR 7' - 2" 0' - 2" 7' - 0" 2' - 0" 2" FROM FINISHED FLOOR OPEN 6X Frameless Glass Door Sauna 2'-6" x 7'-2" C PROPOSED SECOND FLOOR 7' - 2" 0' - 0" 7' - 2" 2' - 6" SWEEP GLASS 7X Frameless Glass Door Sauna 3'0" x 7'-0" C PROPOSED SECOND FLOOR 7' - 0" 0' - 0" 7' - 0" 3' - 0" SWEEP GLASS 8X Frameless Glass Door WC 2'-0" x 6'-2" B PROPOSED SECOND FLOOR 7' - 2" 1' - 0" 6' - 2" 2' - 0" 12" FROM FINISHED FLOOR OPEN 9X Frameless Glass Door WC 3'0" x 6'-2" WATER CLOSET B PROPOSED SECOND FLOOR 7' - 2" 1' - 0" 6' - 2" 3' - 0" 2" FROM FINISHED FLOOR OPEN 10X Frameless Glass Door Sauna 3'0" x 7'-0" C PROPOSED SECOND FLOOR 7' - 0" 0' - 0" 7' - 0" 3' - 0" SWEEP GLASS 11X Frameless Glass Door Sauna 2'-6" x 7'-2" C PROPOSED SECOND FLOOR 7' - 2" 0' - 0" 7' - 2" 2' - 6" SWEEP GLASS 12X Frameless Glass Door Shower 3'0" x 7'-0" A PROPOSED SECOND FLOOR 7' - 2" 0' - 2" 7' - 0" 3' - 0" 2" FROM FINISHED FLOOR OPEN 13X Frameless Glass Door Shower 2'-0" x 7'-0" A PROPOSED SECOND FLOOR 7' - 2" 0' - 2" 7' - 0" 2' - 0" 2" FROM FINISHED FLOOR OPEN 14X Frameless Glass Door Entry 3'-0" x 8'-0" D PROPOSED SECOND FLOOR 8' - 0" 0' - 2" 7' - 10" 3' - 0" 2" FROM FINISHED FLOOR NONE 2 09/30/15