Loading...
HomeMy WebLinkAboutA5.01 - BD.pdfPROPOSED CONDITION AT STONE OR TILE PROPOSED CONDITION AT MEMBRANE DECK DETAIL AT POST OR END PREFORMED COOPER POST CAP EXISTING RAILING MODIFIED & POWDER COATED 4X4 POST HELD 2" OFF WALL FACE OF WALL (VARIES) PREFORMED COOPER POST CAP EXISTING RAILING MODIFIED & POWDER COATED POST SUPPORT PER STRUCTURAL COPPER FLASHING SLOPED 1_ 4 " TO INSIDE 3_ 4 " TREATED PLYWOOD TYVEK BOTH SIDES EXISTING POST & SHEATHING HARDI PANEL ON TYVEK COPPER FLASHING COPPER FLASHING NEW DECK WATERPROOFING EXISTING DECK STRUCTURE VARIES: FIELD VERIFY NEW HARDI PANEL SOFFIT NEW COPPER DRIP FLASHING UNDER VYCOR 2X2 REDWOOD OR TREATED SPACERS @ 16" O.C. 2X12 "REALTRIM" BELLY BAND 2 PIECE AS REQUIRED COPPER CAP FLASHING HARDI PLANK LAP SIDING 8" EXPOSURE WRAP TOP WITH VYCOR PREFORMED COOPER POST CAP 4X4 POST HELD 2" OFF WALL FACE OF WALL (VARIES) PREFORMED COOPER POST CAP EXISTING RAILING MODIFIED & POWDER COATED POST SUPPORT PER STRUCTURAL COPPER FLASHING SLOPED 1_ 4" TO INSIDE 3_4 " TREATED PLYWOOD TYVEK BOTH SIDES EXISTING WOOD TRIM HARDI PANEL ON TYVEK COPPER FLASHING COPPER FLASHING NEW DECK WATERPROOFING NEW COPPER DRIP FLASHING UNDER VYCOR 2X2 REDWOOD OR TREATED SPACERS @ 16" O.C. 2X12 "REALTRIM" BELLY BAND 2 PIECE AS REQUIRED COPPER CAP FLASHING HARDI PLANK LAP SIDING 8" EXPOSURE WRAP TOP WITH VYCOR 1_ 4 " X "X" (FIELD VERIFY) PLATE PAINTED BLACK WITH MOUNTING TABS TO POSTS (beyond) PLATE IS TO BE 2" OUT FROM EDGE OF FINISHES TO ALLOW DRAINAGE EXISTING FLASHING NEW TREATED 3_ 4 " PLYWOOD WITH VYCOR ON FACE NEW TREATED 3_ 4 " PLYWOOD WITH VYCOR ON FACE PROPOSED CONDITION AT STONE OR TILE PROPOSED CONDITION AT MEMBRANE DECK DETAIL AT TYPICAL DRAINAGE OPENING PREFORMED COOPER POST CAP EXISTING RAILING MODIFIED & POWDER COATED 4X4 POST HELD 2" OFF WALL FACE OF WALL (VARIES) PREFORMED COOPER POST CAP EXISTING RAILING MODIFIED & POWDER COATED POST SUPPORT PER STRUCTURAL COPPER FLASHING SLOPED 1_ 4 " TO INSIDE 3_ 4 " TREATED PLYWOOD TYVEK BOTH SIDES EXISTING POST & SHEATHING HARDI PANEL ON TYVEK COPPER FLASHING COPPER FLASHING NEW DECK WATERPROOFING EXISTING DECK STRUCTURE VARIES: FIELD VERIFY NEW HARDI PANEL SOFFIT NEW COPPER DRIP FLASHING UNDER VYCOR 2X2 REDWOOD OR TREATED SPACERS @ 16" O.C. 2X12 "REALTRIM" BELLY BAND 2 PIECE AS REQUIRED COPPER CAP FLASHING 2X2 SPACER SET1_ 4 " ABOVE PLYWOOD TO CREATE SLOPE HARDI PLANK LAP SIDING 8" EXPOSURE WRAP TOP WITH VYCOR PREFORMED COOPER POST CAP EXISTING RAILING MODIFIED & POWDER COATED RAISE RAILING AS NEEDED TO ENSURE 43" HEIGHT ABOVE FINISHED DECK SURFACE 4X4 POST HELD 2" OFF WALL FACE OF WALL (VARIES) PREFORMED COOPER POST CAP EXISTING RAILING MODIFIED & POWDER COATED POST SUPPORT PER STRUCTURAL COPPER FLASHING SLOPED 1_ 4 " TO INSIDE 3_4 " TREATED PLYWOOD TYVEK BOTH SIDES EXISTING WOOD TRIM HARDI PANEL ON TYVEK COPPER FLASHING COPPER FLASHING NEW DECK WATERPROOFING NEW COPPER DRIP FLASHING UNDER VYCOR 2X2 REDWOOD OR TREATED SPACERS @ 16" O.C. 2X12 "REALTRIM" BELLY BAND 2 PIECE AS REQUIRED COPPER CAP FLASHING HARDI PLANK LAP SIDING 8" EXPOSURE WRAP TOP WITH VYCOR 1_ 4 " X "X" (FIELD VERIFY) PLATE PAINTED BLACK WITH MOUNTING TABS TO POSTS (beyond) PLATE IS TO BE 2" OUT FROM FINISHES TO ALLOW DRAINAGE EXISTING FLASHING NEW TREATED 3_ 4 " PLYWOOD WITH VYCOR ON FACE NEW TREATED 3_ 4 " PLYWOOD WITH VYCOR ON FACE DECK DETAIL AT POST OR END DECK DETAIL AT TYPICAL DRAINAGE OPENING EXISTING RAILING MODIFIED & POWDER COATED RAISE RAILING AS NEEDED TO ENSURE 43" HEIGHTABOVE FINISHED DECK SURFACE NOTE: RAILING IS TO BE SET AT 43" (MIN) ABOVE ANY FINISHED DECK SURFACE INCLUDING EXISTING OR NEW MATERIALS. ADJUST POST HEIGHT ACCORDINGLY AS REQUIRED. 2X2 SPACER SET1_ 4 " ABOVE PLYWOOD TO CREATE SLOPE 2X2 SPACER SET1_ 4" ABOVE PLYWOOD TO CREATE SLOPE 2X2 SPACER SET1_ 4 " ABOVE PLYWOOD TO CREATE SLOPE NOTE: RAILING IS TO BE SET AT 43" (MIN) ABOVE ANY FINISHED DECK SURFACE INCLUDING EXISTING OR NEW MATERIALS. ADJUST POST HEIGHT ACCORDINGLY AS REQUIRED. 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 600 Vail Valley Drive Vail, Colorado 81657 A5.01 BALCONY & RAIL DETAILS Northwoods Renaissance Project #1022 02/27/15 PERMIT SET 1" = 1'-0" A5.01 1 DECK RAILING DETAIL 04/20/15