Loading...
HomeMy WebLinkAboutB15-0050 cut sheets.pdfRheem Classic®Series Multi position Gas Furnaces FORM NO. G11-537 REV. 1 R95P- Series 95% A.F.U.E.† Input Rates from 40 to 115 kBTU [11.72 to 33.71 kW] •95% residential gas furnace CSA certified •4 way multi-poise design •PlusOne™Diagnostics 7-Segment LED all units •PlusOne™Ignition System – DSI for reliability and longevity •PlusOne™Water Management System with patented Blocked Drain Sensor •Heat exchanger is removable for improved serviceability. Aluminized steel primary and stainless steel secondary con- struction provide maximum corrosion resistance and thermal fatigue reliability. •Low profile “34 inch” cabinet ideal for space constrained installations. •Blower Shelf design – serviceable in all furnace orientations •Pre marked hoses – insures proper system drainage •Vent with 2" or 3" PVC •Replaceable Collector box •Hemmed edges on cabinet and doors •Quarter turn fasteners for tool less access •Integrated control boards feature dip switches for easy system set up •Self priming condensate trap Air Gas Furnaces R95P Series ✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. Air Table of Contents R95P Series 2 TABLE OF CONTENTS Standard & Optional Equipment ......................................................................3 Physical Data & Specifications ........................................................................4 Model Number Identification............................................................................5 Dimensional Data............................................................................................6 Blower Performance Data................................................................................7 Accessories....................................................................................................8 Limited Warranty ............................................................................................9 Air Standard & Optional Equipment R95P Series 3 STANDARD EQUIPMENT Completely assembled and wired; blocked drain sensor, 7 segment LED and marked hoses; heat exchanger; primary: aluminized steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self-test diagnos- tics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connec- tions; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.) OPTIONAL EQUIPMENT Side and bottom filter racks; return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burn- ers. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES PRIMARY AND SECONDARY HEAT EXCHANGER IN-SHOT BURNERS PRESSURE SWITCHES DRAFT INDUCER CONTROL BOARD GAS VALVE AND MANIFOLD DIRECT SPARK IGNITION & REMOTE SENSOR REMOTE SENSOR BLOCKED DRAIN SENSOR Air Physical Data & Specifications R95P Series 4 Physical Data and Specifications—Upflow Models U.S. and Canadian Models MODEL NUMBERS R95PA0401317MSA R95PA0601317MSA R95PA0701317MSA R95PA085121MSA R95PA1001521MSA R95PA1151524MSA HIGH FIRE INPUT BTU/HR [kW] ➀42,000 [12.31]56,000 [16.41]70,000 [20.50]84,000 [24.61]98,000 [38.71]112,000 [32.82] HEATING CAPACITY BTU/HR [kW]40,320 [11.82]53,760 [15.75]67,200 [19.68]80,640 [23.63]94,080 [37.16]107,520 [31.51] HIGH ALTITUDE OUTPUT 10% DERATE [kW]➁36,288 [10.64]48,384 [14.18]60,480 [17.72]72,576 [21.28]84,672 [24.81]96,768 [28.36] BLOWER (D x W) [mm] 11 x 7 [279 x 178] 11 x 8 [279 x 203] 11 x 8 [279 x 203] 11 x 10 [279 x 254] 11 x 10 [279 x 254] 11 x 11 [279 x 279] MOTOR H.P. [W]– TYPE 1/4 [187]-4-PSC 1/2 [373]-4-PSC 1/2 [373]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC MOTOR FULL LOAD AMPS 4.0 6.8 6.8 8.3 8.3 8.3 HEATING SPEED MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH MINIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa].18 [.045].20 [.050].23 [.057].28 [.070].28 [.070].28 [.070] MAXIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa]0.8 [0.19]0.8 [0.19]0.8 [0.19]0.8 [0.19]0.8 [0.19]0.8 [0.19] HEATING CFM @ .2" [.049 kPa] W.C. E.S.P. [L/s]1049 [494]1139 [537]1211 [571]1704 [804]1748 [825]1750 [825] COOLING CFM @ .5" [.124 kPa] W.C. E.S.P. [L/s]1121 [528]1232 [581]1318 [622]1742 [822]1782 [841]1934 [912] TEMPERATURE RISE-HIGH FIRE RANGE IN DEGREES °F [°C] 25 - 55 [14 -31] 35 - 65 [19 - 36] 40 - 70 [22 - 39] 35 - 65 [19 - 36] 35 - 65 [19 - 36] 45 - 75 [25 - 42] RETURN AIR CABINETS (OPT.) RXGR- FILTER SIZE [mm] C17B (2) 12" x 16" [305 x 406] C17B (2) 12" x 16" [305 x 406] C17B (2) 12" x 16" [305 x 406] C21B (2) 12" x 20" [305 x 508] C21B (2) 12" x 20" [305 x 508] C24B (2) 24" x 16" [609 x 406] APPROX. SHIPPING WEIGHT (LBS.) [kg]123.5 [56]128 [58]132 [60]147.5 [67]152 [69]165 [75] AFUE ➂95.00%95.00%95.00%95.00%95.00%95.00% NOTES: All models are 115V, 60HZ, 1 phase Gas connection size for all models is 1/2" [13 mm] N.P.T. ➀Installation instructions for high altitude derate. ➁ Canadian installations only. ➂In accordance with D.O.E. test procedures. *S=Standard Models NOTE: Standard model complies with California low nox requirements. [ ] Designates Metric Conversions Air Model Number Identification R95P Series 5 Model Number Identification R 95 P A 040 1 3 17 M S A Rheem Series 95% Efficient Motor - PSC Design Series A = 1st Design Input BTU/HR 040 = 42,000 [12.31 kW] 060 = 56,000 [16.41 kW] 070 = 70,000 [20.51 kW] 085 = 84,000 [24.62 kW] 100 = 98,000 [28.72 kW] 115 = 112,000 [32.82 kW] Stage - Single Airflow 3 - Up to 3 Tons 5 - Up to 5 Tons Cabinet Width 17 = 17.5" 21 =21.0" 24 =24.5" Configuration - Multi-Position S = Standard Revision - Marketing (A - First Time Release) — [ ] Designates Metric Conversions Air Dimensional Data R95P Series 6 MODEL R95P LEFT SIDE MINIMUM CLEARANCE (IN.) [mm]SHIP WGTS. FLANGE DIMENSIONS RIGHT SIDE BACK TOP FRONT VENT A B C 040 0 0 0 1 [25]2 [51]0 123.5 [56]171/2 [445]1617/64 [413]1613/64 [412] 060 0 0 0 1 [25]2 [51]0 128 [58]171/2 [445]1617/64 [413]1613/64 [412] 070 0 0 0 1 [25]2 [51]0 132 [60]171/2 [445]1617/64 [413]1613/64 [412] 085 0 0 0 1 [25]2 [51]0 147.5 [67]21 [533]1949/64 [502]1945/64 [500] 100 0 0 0 1 [25]2 [51]0 152 [69]21 [533]1949/64 [502]1945/64 [500] 115 0 0 0 1 [25]2 [51]0 165 [75]241/2 [662]2317/64 [591]2313/64 [589] UNIT DIMENSIONS (CLEARANCE TO COMBUSTIBLES) UNIT DIMENSIONS (CLEARANCE TO COMBUSTIBLES) *A service clearance of at least 24" is recommended in front of all furnaces [ ] Designates Metric Conversions Supply and return depicted as upflow configuration. Flange configuration will vary depending on installation orientation. Air Blower Performance Data R95P Series 7 MODEL BLOWER SIZE [mm] MOTOR H.P. [W] BLOWER SPEED CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa] 0.1 [.02]0.2 [.05]0.3 [.07]0.4 [.10]0.5 [.12]0.6 [.15]0.7 [.17]0.8 [.19] R95PA 0401317 11 x 7 [279 x 178] 1/4 [187] LOW MED-LO MED-HI* HIGH 732 [345] 875 [413] 1073 [506] 1279 [603] 695 [328] 845 [399] 1049 [495] 1239 [584] 669 [316] 820 [387] 1004 [474] 1213 [572] 639 [301] 792 [374] 975 [460] 1174 [554] 605 [285] 766 [361] 943 [445] 1121 [529] 547 [258] 726 [342] 900 [425] 1069 [504] 512 [242] 659 [311] 864 [408] 1033 [487] 487 [230] 605 [286] 798 [376] 980 [462] R95PA 0601317 11 x 8 [279 x 203] 1/2 [373] LOW MED-LO MED-HI* HIGH 830 [392] 940 [443] 1168 [551] 1421 [670] 793 [374] 908 [428] 1139 [537] 1385 [653] 755 [356] 875 [413] 1109 [523] 1349 [636] 705 [333] 821 [387] 1060 [500] 1291 [609] 654 [308] 766 [361] 1010 [476] 1232 [581] 599 [283] 710 [333] 942 [444] 1147 [541] 544 [257] 653 [308] 874 [412] 1062 [501] 496 [234] 584 [275] 802 [378] 976 [460] R95PA 0701317 11 x 8 [279 x 203] 1/2 [373] LOW MED-LO MED-HI* HIGH 852 [402] 986 [465] 1238 [584] 1493 [704] 827 [390] 955 [450] 1211 [571] 1452 [685] 802 [378] 923 [435] 1183 [558] 1410 [665] 752 [355] 883 [417] 1139 [537] 1364 [643] 701 [331] 843 [398] 1094 [516] 1318 [622] 662 [312] 790 [373] 1036 [489] 1257 [593] 623 [294] 737 [348] 978 [461] 1195 [564] 580 [274] 686 [324] 897 [423] 1084 [511] R95PA 0851521 11 x 10 [279 x 254] 3/4 [559] LOW MED-LO MED-HI* HIGH 1313 [619] 1488 [702] 1732 [817] 1983 [935] 1275 [601] 1452 [685] 1704 [804] 1929 [910] 1236 [583] 1415 [667] 1676 [791] 1874 [884] 1221 [576] 1384 [653] 1630 [769] 1810 [854] 1184 [558] 1328 [626] 1579 [745] 1742 [822] 1141 [538] 1279 [603] 1498 [707] 1663 [784] 1098 [518] 1229 [580] 1417 [668] 1583 [747] 1053 [497] 1170 [552] 1343 [633] 1477 [697] R95PA 1001521 11 x 10 [279 x 254] 3/4 [559] LOW MED-LO MED-HI* HIGH 1329 [627] 1535 [724] 1796 [847] 2019 [952] 1313 [619] 1498 [707] 1748 [825] 1961 [925] 1296 611] 1461 [689] 1700 [802] 1903 [898] 1260 [594] 1422 [671] 1656 [781] 1843 [869] 1224 [577] 1382 [652] 1612 [760] 1782 [841] 1171 [552] 1325 [625] 1536 [725] 1687 [796] 1117 [527] 1268 [598] 1460 [689] 1592 [751] 1049 [495] 1203 [567] 1370 [646] 1489 [702] R95PA 1151524 11 x 11 [279 x 279] 3/4 [559] LOW MED-LO MED-HI* HIGH 1249 [589] 1440 [679] 1770 [835] 2123 [1001] 1234 [582] 1429 [674] 1750 [825] 2077 [980] 1219 [575] 1417 [668] 1730 [816] 2031 [958] 1183 [558] 1381 [651] 1696 [800] 1983 [935] 1146 [541] 1344 [634] 1662 [784] 1934 [912] 1112 [525] 1313 [619] 1611 [760] 1856 [875] 1078 [508] 1281 [604] 1559 [735] 1777 [838] 1017 [480] 1221 [576] 1463 [690] 1665 [785] *Factory setting for heat all grey cells are valid heating settings. Do not use speed tabs and/or static pressure which do not fall into the grey cells on this table. NOTE: Unit tested without filters. [ ] Designates Metric Conversions. Air Accessories R95P Series 8 *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter. FILTER RACK FILTER SIZES* INCHES [mm] MODEL RXGF-CB (UPFLOW/ HORIZONTAL) RXGF-CD (UPFLOW) RXGF-CC (DOWNFLOW) R95PA040 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 12 x 20 [305 x 508] R95PA060 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 12 x 20 [305 x 508] R95PA070 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 12 x 20 [305 x 508] R95PA085 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 12 x 20 [305 x 508] R95PA100 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 12 x 20 [305 x 508] R95PA115 223/4 x 25 [578 x 635] 153/4 x 25 [400 x 635] 14 x 20 [356 x 508] FOR HIGH ALTITUDES: NOTE:For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations. See installation instructions as appropriate orifice change is required. L.P. CONVERSION KIT: RXGJ-FP33 RETURN AIR PLENUM KIT: RXGR-C17B RXGR-C21B RXGR-C24B CONDENSATE PUMP KIT: PROSTOCK & 1PCB151TUL DOWNFLOW/HORIZONTAL CONVERSION KIT: RXGY-CK DOWNFLOW/HORIZONTAL LEFT ZERO CLEARANCE CONVERSION KIT: RXGY-ZK COMBUSTIBLE FLOOR BASE: RXGC-B17 RXGC-B21 RXGC-B24 [ ] Designates Metric Conversions INDOOR COIL CASINGS MODEL NUMBER RXBC-D17A1 RXBC-D21A1 RXBC-D21B1 RXBC-D24A1 VENT TERMINATION KITS: = RXGY-E02: Vertical/Horizontal Concentric Vent Termination Kit 2" Pipe (US Only) RXGY-E02A: Vertical/Horizontal Concentric Vent Termination Kit 2" Pipe (US & Canadian) RXGY-E03: Vertical/Horizontal Concentric Vent Termination Kit 3" Pipe (US Only) RXGY-E03A: Vertical/Horizontal Concentric Vent Termination Kit 3" Pipe (US & Canadian) RXGY-G02: Direct Vent Furnace Side Wall Vent 2" or 3" (US Only) RXGY-D05: Combustion Air Drain Kit 2" RXGY-D06: Combustion Air Drain Kit 3" NEUTRALIZER KIT: RXGY-A01 (Replacement Cartridge 54-22120-01) FOSSIL FUEL KIT: RXPF-F01, RXPF-F02 (TVA) RETURN AIR PLENUM:RXGR-C17B RXGR-C21B RXGR-C24B EXTERNAL BOTTOM FILTER (UPFLOW/HORIZONTAL) RACK: RXGF-CB EXTERNAL SIDE (UPFLOW) FILTER RACK:RXGF-CD EXTERNAL (DOWNFLOW) FILTER RACK:RXGF-CC Air Limited Warranty R95P Series 9 GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Parts (Registration Required)...............................Ten (10) Years Heat Exchanger .........................................Limited Lifetime Air Notes R95P Series 10 Air Notes R95P Series 11 The new degree of comfort.™ Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. PRINTED IN U.S.A 05/13 QG FORM NO. G11-537 REV. 1 Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5