HomeMy WebLinkAboutB15-0057 final inspection.pdf08-06-2015 4:05 pm Inspection Re~uest Reporting Vail, CO • City 0 Requested Inspect Date: Friday, August 07z,2015 Site Address: 1339 WESTHAVEr.i CR VAIL A/P/D Information Activity: B15-0057 Type: COMBO Sub TY.pe: ASFR Const Type: Occupancy: Ose: R-3 Owner: HOVEY, NANCY M. Applicant: BECK BUILDING COMPANY Phone: 970-949-1800 Contractor: BECK BUILDING COMPANY Phone: 970-949-1800 Page 7 Status: ISSUED lnsp Area: Description: Interior GRFA conversion of existing 5' headroom height crawlspace into storage area. Add wirsbo in slab for future heating system. Add future underground plumo1n_g_for toilet waste line. (rough in only) Notice: REV1 no temp shoring needed -Structural Revisions. GC lowered the valuation by $30,000. This is reflected on Revisions screen. Once it has been approved by Building Dept. that no temp shoring is needed then the taxes/use tax needs to be manuallv adjusted and if there 1s a refund due to GC then a refund needs to be Qrocessed with TOV Finance Dept. -CGODFREY Notice: Projectdox -CGODFREY Comment: Steel Inspection Report routed to projectdox and JR -CGODFREY Comment: S~ecial Inspection routed to wojectdox and MH -CGODFREY Comment: REV1 routed to Projectdox -CGODFREY Comment: emailed contractor read for issuance -MHAEBERLE ,.--j Comment: REV2 add wirsbo in sla and plumbing routed to Projectdox -CGO REY Requested Inspection(&) 0 Requester: BECK BUILDING COMPAN P e· Item: 542 PLAN-FINAL \ Requested Time: Comments: 376-4345 Assigned To: GRUTHER Action: Item: 90 BLDG-Final Requester: BECK BUILDING COMPANY Comments: 376-4345 Assigned To: JMONDRAGON Action: Time p: Comment: all building elements complete · st waiting for final SI report Inspection History Item: 10 BLDG-FOOTING ••App ved •• 04/20/15 Inspector· sgremmer Comment: 2 pad loo · g 05/04/15 Inspector: sgremmer Comment: rear wall 05/07/15 Inspector: sgremmer Comment: 6' of footing at south wall 05/18/15 Inspector: sgremmer Comment: Item: 20 BLDG-Foundation/Steel ••Approved•• 05/07/15 Inspector: sgremmer Comment: east foundation wall complete 05/07/15 Inspector: JRM Comment: MIDDLE SECTION ONLY 05/18/15 Inspector: sgremmer Comment: Item: 120 ELEC-Rough ••Approved •• 06/18/15 Inspector: CC Comment: Item: 220 PLMB-Rough/D.W .V. ••Approved•• 05/22/15 lns12ector: JRM Comment: 10 FT HEAD 06/18/15 Inspector: CC Comment: Item: 230 PLMB-Rough/Water ••Approved•• 06/18/15 Inspector: CC Comment: Item: 200 MECH-Rough ••Approved•• 06/01 /1 S-Inspector: sgremmer Comment: lnfloor heat 06/18/15 Inspector: CC Comment: Item: 30 BLDG-Framing ••Approved•• REPT131 Action: Action: Pl PARTIAL INSPECTION Action: Pl PARTIAL INSPECTION Action: AP APPROVED Action: Pl PARTIAL INSPECTION Action: Pl PARTIAL INSPECTION Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Run Id: 15001