HomeMy WebLinkAboutLoad Calcs.pdfLOAD CALCULATION PER N.E.C. EXAMPLE D1 ( a ) HOVEY RESIDENCE - 02/26/2015 240-V / 1-PH SUPPLY GENERAL LOAD -LOAD IN VOLT-AMPS 6,697 SQ. FT. @ 3W/FT 20,091.00 SMALL APPLIANCE 3,000.00 LAUNDRY / APPLIANCES 1,500.00 TOTAL 24,591.00 3000VA @ 100%3,000.00 20,091VA - 3,000VA = 17,091VA @ 35%5,982.00 NET LOAD 8,982.00 CLOTHES DRYERS - @ 5 KVA EACH 5,000.00 MICROWAVE - 1 @ 1200 VA EACH 1,200.00 SUB ZERO - 3 @ 1200 VA EACH 220.53 @ 75%2,700.00 FREEZER - 1 @ 1000 VA EACH 220.53 @ 75%750.00 DISHWASHER - 2 @ 1200 VA EACH 220.53 @ 75%1,800.00 DISPOSAL - 2 @ 800 VA EACH 220.53 @ 75%1,200.00 HEAT TRACE 3,600.00 HOT TUB 10,000.00 ELECTRIC OVEN - 2 @ 11KW TOTAL TABLE 220.55 11,000.00 BOILER HEATING LOAD 1,500.00 NET CALCULATED LOAD 47,732.00 MINIMUM FEEDER AMPS 198.88 SERVICE BUSSING / MAIN AMPACITY 200.00