HomeMy WebLinkAboutPL1.3.pdfNOTES:
1. DEPTH MARKER SHALL BE NON-SLIP TILES WITH BLACK NUMERALS AND LETTERS.
2. "NO DIVING" MARKERS SHALL BE NON-SLIP TILES WITH BLACK LETTERS. THE NO DIVING
SYMBOL SHALL BE IMPRINTED ON THE TILE. THE TILES SHALL BE RECESSED SO THAT THE FACE
OF THE TILE IS FLUSH WITH FINISHED SURFACE OF POOL DECK OR SPA WALL.
3. DEPTH SHALL BE VERIFIED BY CONTRACTOR AND MARKERS SHALL BE INSTALLED TO INDICATE
ACTUAL DEPTH OF WATER.
4. WALL AND DECK DEPTH MARKERS SHALL BE SPACED AT NOT MORE THAN 25 FOOT
INTERVALS, MEASURED PERIPHERALLY. REFER TO PLAN FOR APPROXIMATE LOCATIONS.
5. POOL DEPTH MARKERS SHALL BE A MINIMUM OF 4" HIGH NUMERALS, AND SHALL BE
LOCATED AT OR ABOVE THE WATER SURFACE AND IN PLAIN VIEW OF THE BATHERS.
6"
6" 6" 6"
WATER
FACE OF SPA
TOP OF COPING
INTERNATIONAL DEPTH MARKER
& "NO DIVING" MARKER
PLAN VIEW
12" TO 16" MAX.
1.90 DIA. STAINLESS
STEEL HANDICAP
TRANSFER HANDRAIL
MIN. 12" LONG
TOP OF DECKING
SECTION VIEW INSIDE OF SPA
INSIDE OF SPA
60" x 60" CLEAR SPACE EACH SIDE OF
TRANSFER RAIL (SLOPE NOT TO EXCEED
1:48)
1'-6"
PLAN VIEW
EQUALIZER LINE
TO EQUIPMENT ROOM
REMOVABLE PLASTIC
COVER LID
12'-0" ALUMINUM POLE
SHEPHERD'S CROOK
24" U.S. COAST GUARD
APPROVED RING BUOY WITH A
LENGTH OF ROPE AT LEAST
EQUAL TO THE MAX. WIDTH OF
THE POOL
13'-0"
2'-014"
'/'4)'0%;
5*76Ä1((
27..614'5'6
52#,'65
SECTION
23
4"
412"
FACE SECTION
SPA JET ACTUATOR
SECTION
41
2"
45
8"
FACE SECTION
SPA JET EMERGENCY SHUT-OFF
STANDARD FINISH ON
SWITCHES IS ALUMINUM
STANDARD FINISH ON
SWITCHES IS ALUMINUM
DOUBLE GANG
JUNCTION BOX,
BY E.C.
SINGLE GANG
JUNCTION BOX,
BY E.C.
STANDARD SIGN WHITE WITH RED
LETTERS, ANY OTHER TO BE CUSTOM
BY G.C.
POOL RULES
1. WARNING: NO LIFEGUARD ON DUTY
2. SHOWER BEFORE ENTERING SPA
3. NO ANIMALS IN SPA OR ON SPA DECK
4. NO FOOD OR DRINK IN SPA OR ON DECK
5. NO DIVING
6. CHILDREN UNDER 12 YEARS OLD MUST BE
7. BATHING LOAD _________ PERSONS
8. EMERGENCY ASSISTANCE ___________
0$;,0807(03(5$785()ߛ&ߜ
ACCOMPANIED BY AN ADULT
POOL HOURS
(STRICTLY ENFORCED)
________ TO________
SPA RULES
1. WARNING: NO LIFEGUARD ON DUTY
2. SHOWER BEFORE ENTERING SPA
3. NO ANIMALS IN SPA OR ON SPA DECK
4. NO FOOD OR DRINK IN SPA OR ON DECK
5. NO DIVING
6. CHILDREN UNDER 12 YEARS OLD MUST BE
7. BATHING LOAD _________ PERSONS
8. EMERGENCY ASSISTANCE ___________
0$;,0807(03(5$785()ߛ&ߜ
ACCOMPANIED BY AN ADULT
SPA HOURS
(STRICTLY ENFORCED)
________ TO________
INSIDE OF SPA
HARTFORD AIR LOOP WITH INSECT SCREEN, INSULATE AROUND
PIPE FOR NOISE & PAINT TO HIDE IN LANDSCAPING
TYPICAL SPA JET AIR LINE
MUST RUN AT LEAST 6"
HIGHER THAN COPING
ELEVATION, TERMINATION
POINT NOT FURTHER
THAN 20'-0"
5'-1" MINIMUM
18" MINIMUM
VGB APPROVED MAIN DRAIN
HYDROSTATIC RELIEF VALVE
CLEAN GRAVEL SURROUNDING
VALVE BY G.C.
FILTER FABRIC, BY G.C.
4" PERFORATED PIPE UNDER DRAIN TO
DE-WATERING SYSTEM, BY G.C.
1'-8"
1" CONDUIT TO
ELECTRICAL PANEL
BY E.C; LOCATION
T.B.D.
120 V. 100 WATT LIGHT AND
NICHE PROVIDED AND INSTALLED
BY P.C. PER SPECS
GROUND CLAMP AND #8 AWG
GROUNDING WIRE TO LIGHT NICHE
BY E.C.
RE-LAMP POSITION;
PROVIDE ENOUGH
CORD
J-BOX PROVIDED
AND INSTALLED
BY E.C.
MIN. 5'-0"
PL1.3DETAILS
SCALE: 1"=1'-0"
HANDICAP TRANSFER RAIL
1
PROJECT:
DRAWING:
COLDSTREAM CONDOS SPA REMODEL
VAIL, COLORADO
DATE ISSUE
8-8-14 PRELIM
10-1-14 REVISIONS
1-16-15 REVISIONS
3-11-15 DD
3-16-15 CD
SCAPES
NOT TO SCALE
DEPTH / NO DIVING MARKERS
2
NOT TO SCALE
SAFETY CROOK AND BUOY PROVIDED BY OWNER
4
SCALE: 1"=1'-0"
SKIMMER SECTION
5
SCALE: 3"=1'-0"
WALL MOUNTED SWITCHES
3
NOT TO SCALE
SAFETY SIGNS PROVIDED BY OWNER
6
SCALE 1"=1'-0"
AIR LOOP
7
SCALE 1"=1'-0"
HYDROSTATIC DRAIN
8
SCALE 1"=1'-0"
SPA LIGHT SECTION
9
09/09/15