HomeMy WebLinkAboutPL2.1.pdfCALL
OUT
SPA EQUIPMENT MAKE & MODEL OR DESCRIPTION
- - CIRCULATION RATE 30 GPM
- - TURN OVER PERIOD 80 MINUTES
F-1 1 SAND FILTER PENTAIR,TR100C SAND FILTER WITH BACKWASH VALVE
- - UNIT FILTER RATE 9.55 GPM/ SF
- - BACKWASH FLOW RATE 110 GPM
- - HEATER REQUIREMENTS 250 BTU
- 1 SPA LIGHT PENTAIR AMERLITE SERIES, POOL LIGHT W/ S/S RINGS, W/ GFCI NEEDED, CORD
LENGTH AS REQUIRED MINIMUM 100'
- 1 SPA SKIMMER PENTAIR, BERMUDA, 2" PORTS, MODEL 506300 (WHITE- T.B.D.)
- 4 SPA INLETS PENTAIR, INSIDER DIRECTIONAL INLETS,11
2" (BLACK)
- 2 MAIN DRAIN SUCTIONS SUMPS LAWSON AQUATICS 12" x 12" SUPER FLOW DRAIN SUMP
-2
MAIN DRAIN SUCTION COVER GRATE
AND THREE PORT SUMP BUCKET
AQUASTAR 32" CHANNEL DRAIN FLAT GRATE ANTI-ENTRAPMENT SUCTION OUTLET
COVER AND ABS THREE-PORT MANUFACTURED SUMP-VGB APPROVED
- 12 HYDRO THERAPY JETS WATERWAY POLY GUNITE JET ASSEMBLY #210-3700 WITH FITTING # 215-1070
(WHITE) & ADJUSTABLE DELUXE JET # 210-6080 (WHITE)
- - SANITATION TYPE CHLORINE EROSION FEED
- - PH CONTROL TYPE MANUAL HAND FEED
CP-1 1 CIRCULATION PUMP PENTAIR, WHISPERFLO 1 HP, 80 GPM @ 50' TDH
JP-1 1 HYDRO-THERAPY JET PUMP PENTAIR, WHISPERFLO, 3 HP, 144 GPM @ 50' TDH
H-1 1 HEATER PENTAIR MASTER TEMP ECO FRIENDLY HEATER 250,000 BTU #460732
- 2 PRESSURE GAUGES -
- 1 FLOW METERS -
- 2 THERMOMETERS -
- 1 SPA THERMAL COVER STANDARD FLOATING THERMAL COVER (COVER REEL NOT INCLUDED)
- 1 SPA CONTROLLER LX-80 CONTROLLER WITH JET BUTTON AND EMERGENCY SHUT-OFF
CF-1 1 CHEMICAL FEEDER-CHLORINATOR WATERWAY CHLORINATOR #CLC012 IN-LINE 12 TABLET FEEDER-2" SOCKET; WITH
#550-6700 IN-LINE CHLORINATOR MOUNTING BRACKET
AF-1 1 AUTO FILL CONTROLLER SYSTEM DYNAMICS, K-1100 LEVELOR, 3
4" SOLENOID VALVE
OG-1 1 SPA OZONE GENERATOR (OPTIONAL) DEL ECLIPSE, EC-2, CORONA DISCHARGE OZONATOR W/ MIXING CHAMBER &
INJECTOR ASSEMBLY (OPTIONAL)
CC-1 1 CHEMICAL CONTROLLER (OPTIONAL) CHEMTROL CH-255 PPM/pH CONTROL, INCLUDE STENNER CHEMICAL FEED PUMP
FOR pH ACID FEED (OPTION)
UV-1 1 ULTRAVIOLET SYSTEM (OPTIONAL) DELTA UV ES-40, INCLUDES S.S. INNER WRAP (OPTIONAL)
- 1
HANDICAP SWIMMING POOL LIFT
(OPTIONAL)
AQUA CREEK PRODUCTS-SCOUT POOL LIFT, ADA COMPLIANT, G.C. TO PROVIDE
ANCHOR SUPPORT
2 SPA EQUIPMENT SCHEDULE
CALL OUT QUANTITY EQUIPMENT NAME VOLT PHASE HP/BY/W
AMPS
EACH
FURNISHED
& SET BY
LOCATION CONTROLS OR INTERLOCKING
HIGH VOLTAGE WIRING,
SWITCHES & CONTACTORS
LOW VOLTAGE
CONTROL WIRING
24 VOLTS OR LESS
VENTING, GAS, COPPER & WATER
PIPING
CP-1 1
CIRCULATION
PUMP
230V 1 1 HP 6.4 A PC EQUIPMENT ROOM
INTERLOCKED W/ POOL CONTROL &
EMERGENCY SHUT OFF
EC PROVIDE 3 PHASE
CONTACTOR/ RELAY
PC ---
JP-1 1 JET PUMP 230V 1 3 HP 13.4 A PC EQUIPMENT ROOM
INTERLOCKED W/ CONTROL SYSTEM
EMERGENCY SHUT OFF & JET BUTTON
--- --- ---
F-1 1 SAND FILTER --- --- --- --- PC EQUIPMENT ROOM --- --- -
MC TO PROVIDE DRAIN FOR
BACKWASH WITH AIR GAP TO
HANDLE 140 GPM
H-1 1 GAS HEATER - -250,000
BTU
- PC EQUIPMENT ROOM
INTERLOCKED W/ SPA CONTROL & FLOW
SWITCH & HIGH LIMIT
EC MC
MC TO PROVIDE GAS SERVICE
AND ALL VENTING
- 1
UNDER WATER
LIGHT
120V 1 100 W 5.0 A PC SPA
INTERLOCKED W/ TIME CLOCK OR PHOTO
VOLTAIC CELL, NICHE & LAMP BY PC.
CONDUIT, J-BOX & WIRING BY EC
EC PC ---
AF-1 1
WATER LEVEL
CONTROL
120V 1 --- <5.0 A PC EQUIPMENT ROOM
INTERLOCK W/ SOLENOID VALVE, MC TO
FURNISH FRESH WATER LINE W/ BACK
FLOW PREVENTER & MANUAL SHUT OFF
EC PC
MC TO FURNISH FRESH WATER
LINE W/ BACK FLOW PREVENTER &
MANUAL SHUT OFF
OG-1 1
OZONE
GENERATOR
(OPTIONAL)
120V 1 --- <15.0 A PC EQUIPMENT ROOM
INTERLOCKED W/ POOL CONTROLS &
FLOW SWITCH HIGH LIMIT
EC PC ---
CC-1 1
CHEMICAL
CONTROLLER
(OPTIONAL)
120V 1 --- <20.0 A PC EQUIPMENT ROOM
INTERLOCK INTELLITOUCH CONTROL W/
ACID FEED PUMP AND CHLORINE FEED
SYSTEM (LIQUID CHLORINE, EROSION
FEED OR CHLORINE GENERATOR)
EC PC ---
UV-1 1
UV SYSTEM
(OPTIONAL) 120V 1 --- <15.0 A PC EQUIPMENT ROOM --- EC --- ---
SPA COORDINATION SCHEDULE
3
ELECTRICAL SUB
PANEL NEEDS TO
BE LOCATED PER
ELECTRICAL
CODE. PANEL
MUST HAVE 6'-6"
CLEARANCE IN
HEIGHT
SPA FILTER
CIRC
PUMP
JET
PUMP
NEW SPA
HEATER
NOTES:
x NEED MECHANICAL TO PROVIDE 3
4" FRESHWATER LINE
WITH RPZ BACK FLOW PREVENTER FOR AUTO FILL LINE
x RE-PLUMBING OF EXISTING POOL MAY BE REQUIRED TO
ACCOMMODATE NEW SPA EQUIPMENT AND PLUMBING
LINES
x NOTE: HEATER REQUIRES TWO UNITERRUPTED AIR
SUPPLY OPENINGS; ONE FOR VENTILATION AND ONE
TO SUPPLY AIR FOR PROPER GAS COMBUSTION.
THE AIR SUPPLY OPENINGS SHOULD BE SIZED
ACCORDING TO TABLE BELOW.
x THE OPENINGS LISTED IN TABLE ARE FREE OPEN
VENT AREA- IF THE BENTS INCORPORATE
RESTRICTIVE LOUVERS, THE BENT OPENINGS MUST
BE INCREASED TO COMPENSATE FOR THE AREA
BLOCKED BY THE LOUVERS (OR GRILLES)
REQUIRED AIR SUPPLY
MODEL
AIR FOR
COMBUSTION
(SQ. IN.)
AIR
VENTILATION
(SQ. FT.)
250 250 250
Electrical
Panel
NEW SPA HEATER, SEE HEATER
NOTES
EXISTING POOL HEATER
TO REMAIN
EXISTING POOL SAND
FILTER TO REMAIN
NEW SPA SAND FILTER MOUNTED ON
METAL STAND
3" SPA MAIN DRAIN SUCTION LINE
2" MAIN DRAIN SKIMMER SUCTION
LINE
4" JET SUCTION LINE
4" SPA JET RETURN LINE
EXISTING POOL CIRC PUMP TO
REMAIN
EXISTING KITCHEN WATER
HEATER TO REMAIN
EXISTING EYE WASH
STATION TO REMAIN
HEATER NOTES
EXISTING
POOL
HEATER
PL2.1
EQUIPMENT LAYOUT AND SCHEDULES
SCALE: 1/2"=1'-0"
EXISTING EQUIPMENT ROOM WITH EQUIPMENT LAYOUT
1
PROJECT:
DRAWING:
COLDSTREAM CONDOS SPA REMODEL
VAIL, COLORADO
DATE ISSUE
8-8-14 PRELIM
10-1-14 REVISIONS
1-16-15 REVISIONS
3-11-15 DD
3-16-15 CD
SCAPES
09/09/15