HomeMy WebLinkAboutSpecial Inspection and Testing Schedule.pdfSPECIAL INSPECTION AND TESTING AGREEMENT
(To applicants of projects requiring Special Inspection or Testing per Section 1701 of the IBC)
The owner or his/her representative, on the advice of the design professional in responsible charge, shall
complete,seal,sign and submit a copy of the Special Inspection Agreement and Structural Tests
Scheduled to the Town of Vail for review and approval.Signatures are required on both pages;
photocopied or faxed signatures are acceptable.
The owner and his/her general contractor, where applicable, shall also acknowledge the following
conditions applicable to Special Inspection Testing:
1.Contractor is responsible for proper notification to the Inspection or Testing agency for items
listed.(Page 1)(IBC 1704)
2.Only the testing laboratory should take samples and transport them to their laboratory.
3.Copies of all laboratory reports and inspections are to be sent directly to the Town of Vail by the Testing
agency on a weekly basis.
4.Inspection agency to submit names and qualifications of on-site special inspectors to the Town of Vail
for review and approval.(Page 2)
5.The special inspector is responsible to immediately notify the Town of Vail Building Official in writing of
any concerns and/or problems encountered.
6.It is the responsibility of the contractor to review the Town of Vail approved plans for additional
inspection or testing requirements that may be noted. A pre-construction conference at the job site is
recommended to review special inspection procedures.
7.The special inspector shall use only the Town of Vail approved drawings.
8.All special inspection field reports must be left on site for review by the Town of Vail staff prior to
required inspections or re-inspections.
BEFORE OCCUPANCY WILL BE GRANTED: The special inspection agency shall submit a signed and
sealed statement that all items requiring testing and inspection were fulfilled and reported. Those items not
tested and/or inspected shall be noted in this statement. A copy of the statement shall be maintained at the
job site for the Building Inspector’s review prior to final inspection.
Acknowledgement:
Owner:
Signature Print Name Date
Special Inspection
Agency:
Signature Print Name Date
Project
Arch/Eng:
Signature Print Name Date
Contractor:
Signature Print Name Date
Job Name:
Job Address:
Permit No.:
-3-
Coldstream Condominiums
1476 Westaven Drive
Heather Duncan 03/20/15
Don MacLachlan, Coldstream
Bill Pierce
David Young, HP Geotech
SPECIAL INSPECTION AND TESTING SCHEDULE
(IBC 1704)
Project Name:Permit #
Owner’s Name:
Testing Inspection Signature Print Name Date
Agency:
Testing Inspection Signature Print Name Date
Hereby certifies that the Testing/Inspection Agency named above has been engaged to perform structural tests and
inspections during construction as checked below, to satisfy all applicable portions of the Building Code.
Prior to final inspection, the Inspection Agency shall submit a statement that all items of designated work performed
were reported. Any items checked but not tested or inspected will be noted and explained. Whenever any designated
items on the list are ready for sampling, testing, or inspection, it shall be the responsibility of the contractor to give
timely notice to the Inspection agency so that the required services may be performed.
REINFORCING STEEL:
_____Tensile & Bend, one set per heat per _____ tons
_____Inspection of Placement
_____Inspection of Welding
_____Epoxy
MASONRY:
_____Prelim. Acceptance Tests (Masonry Units, Wall Prisms)
_____Subsequent Tests (Mortar, Grout, Field Wall Prisms)
_____Inspection of Placement and Grouting
CONCRETE, SHOTCRETE, GROUT AND MORTAR:
Concrete Shot Grout Mortar
Aggregate tests for design
Suitability of aggregates
Mix Designs
Test Panel
Batch Plant Inspection
Cement Grab Sample
Inspect Placing
Compression Tests
Cast Specimens
Pick-up Samples
Shrinkage Bars
Yield Check
Air Check
Dry Unit Weight
PRECAST CONCRETE:
_____Reinforcing Tests
_____Inspection of Reinforcing Placement
_____Tendon Tests
_____Inspection of Tendon Placement
_____Inspection of Concrete Placement
_____Inspection of Concrete Batching
_____Inspection of Panel Attachment & Inserts
_____Compression Tests
_____Inspection of Stressing/Transfer
PILING, CAISSONS, CAPS, TIES:
_____Inspection of Reinforcing Placement
_____Inspection of Concrete Placement
_____Inspection of Concrete Batching
Specify other tests, inspections or special instructions required.
UNDERPINNING:
_____Temporary/Permanent
_____Inspection of Steel Fabrication
_____Inspection of Reinforcing & Forms
_____Inspection of Concrete Placement
_____Inspection of Tiebacks
_____SOIL NAILS:
_____Temporary Shoring
_____Permanent Wall
STRUCTURAL STEEL:
_____Sample & Test (List specific members below)
_____Shop Identification & Welding Inspection
_____Shop Ultrasonic Inspection
_____Shop Radiography
_____Field Welding Inspection
_____Field Bolting Inspection
_____Field Ultrasonic Inspection
_____Field Radiography
_____Metal Deck Welding Inspection
FIREPROOFING:
_____Inspection & Placement
SOILS:
_____Acceptance Tests
_____Moisture-Density Determination
_____Field Density
_____Drilled Piers
_____Deep Foundation
STRUCTURAL WOOD:
_____Inspection of Fabrication
_____Inspection of Truss Joint Fabrication
_____Sample & Test Components
_____Inspection of Glu Lam Fabrication
_____SMOKE CONTROL:
_____SPECIAL CASES:
SPECIAL INSPECTION:
_____Seismic Resistance
_____Wind Requirements
-4-
Coldstream Condominiums
X
X
David Young, HP Geotech