Loading...
HomeMy WebLinkAboutB15-0095 Electrical Calcs.pdfr Load Calc For XMcSimba Run Per 220.83 NEC Existing Dwelling Unit 1080 Sq.Ft *NV General Lighting 1070X3" 3210 Small appliance and laundry 3X1500 4500 Appliances with new microwave 3000 Range 8500 Dryer 5000 Total 24210 First 8kva 100% 8000 Remainder at 40% 6484 Electric Heat 6000 Total Load 20484/208 = 98.48 amps Existing Service 125 amps Tenmats will be installed above can lights