HomeMy WebLinkAboutTalisman U Values.pdfCM-6
CASEMENT
Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
Architect Series®Designer Series® Pella® ProLine 450
GLAZING PERFORMANCE - TOTAL UNIT
Aluminum-Clad Wood
Vent
Glazing ThicknessType of Glazing NFRC Certified
Product #
Glass
(mm)
Gap
Fill
Performane Values1
Shaded Areas Meet
ENERGY STAR® Performance
Criteria in Zones Shown
Ext. Int.U-FactorSHGCVLT %CRU. S. Canada 2
Zone ER Zone
HIGH ALTITUDE GLAZING N NC SC S 1 2 3
11/16" Advanced Low-E IG PEL-N-11-09108-00001 2.5 2.5 air 0.31 0.26 48 58
with grilles-between-the-glass PEL-N-11-09730-00001 0.31 0.24 44 58
with integral grilles PEL-N-11-09318-00001 0.32 0.24 44 58
11/16" Advanced Low-E IG PEL-N-11-09109-00001 3 3 air 0.32 0.26 48 57
with grilles-between-the-glass PEL-N-11-09731-00001 0.32 0.24 43 57
with integral grilles PEL-N-11-09319-00001 0.32 0.24 43 57
11/16" SunDefense Low-E IG PEL-N-11-09121-00001 2.5 2.5 air 0.31 0.20 45 58
with grilles-between-the-glass PEL-N-11-09743-00001 0.31 0.18 41 58
with integral grilles PEL-N-11-09331-00001 0.32 0.18 41 58
11/16" SunDefense Low-E IG PEL-N-11-09122-00001 3 3 air 0.31 0.20 44 57
with grilles-between-the-glass PEL-N-11-09744-00001 0.31 0.18 40 57
with integral grilles PEL-N-11-09332-00001 0.32 0.18 40 57
11/16" AdvancedComfort Low-E IG PEL-N-11-10652-00001 2.5 2.5 air 0.27 0.26 47 45 21
with grilles-between-the-glass PEL-N-11-10694-00001 0.27 0.23 43 45 19
with integral grilles PEL-N-11-10666-00001 0.28 0.23 43 45 18
11/16" AdvancedComfort Low-E IG PEL-N-11-10653-00001 3 3 air 0.27 0.26 47 44 21
with grilles-between-the-glass PEL-N-11-10695-00001 0.27 0.23 42 44 19
with integral grilles PEL-N-11-10667-00001 0.28 0.23 42 44 18
11/16" NaturalSun Low-E IG PEL-N-11-09079-00001 2.5 2.5 air 0.32 0.48 55 57 27
with grilles-between-the-glass PEL-N-11-09701-00001 0.32 0.44 50 57 25
with integral grilles PEL-N-11-09289-00001 0.33 0.44 50 57
11/16" NaturalSun Low-E IG PEL-N-11-09080-00001 3 3 air 0.32 0.47 54 56 27
with grilles-between-the-glass PEL-N-11-09702-00001 0.32 0.43 49 56 25
with integral grilles PEL-N-11-09290-00001 0.33 0.43 49 56
(1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY STAR® values are
updated to 2015 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor
SHGC = Solar Heat Gain Coefficient
VLT % = Visible Light Transmission
CR = Condensation Resistance
ER = Canadian Energy Rating
Climate Zones