Loading...
HomeMy WebLinkAboutTalisman U Values.pdfCM-6 CASEMENT Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com Architect Series®Designer Series® Pella® ProLine 450 GLAZING PERFORMANCE - TOTAL UNIT Aluminum-Clad Wood Vent Glazing ThicknessType of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performane Values1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext. Int.U-FactorSHGCVLT %CRU. S. Canada 2 Zone ER Zone HIGH ALTITUDE GLAZING N NC SC S 1 2 3 11/16" Advanced Low-E IG PEL-N-11-09108-00001 2.5 2.5 air 0.31 0.26 48 58 with grilles-between-the-glass PEL-N-11-09730-00001 0.31 0.24 44 58 with integral grilles PEL-N-11-09318-00001 0.32 0.24 44 58 11/16" Advanced Low-E IG PEL-N-11-09109-00001 3 3 air 0.32 0.26 48 57 with grilles-between-the-glass PEL-N-11-09731-00001 0.32 0.24 43 57 with integral grilles PEL-N-11-09319-00001 0.32 0.24 43 57 11/16" SunDefense Low-E IG PEL-N-11-09121-00001 2.5 2.5 air 0.31 0.20 45 58 with grilles-between-the-glass PEL-N-11-09743-00001 0.31 0.18 41 58 with integral grilles PEL-N-11-09331-00001 0.32 0.18 41 58 11/16" SunDefense Low-E IG PEL-N-11-09122-00001 3 3 air 0.31 0.20 44 57 with grilles-between-the-glass PEL-N-11-09744-00001 0.31 0.18 40 57 with integral grilles PEL-N-11-09332-00001 0.32 0.18 40 57 11/16" AdvancedComfort Low-E IG PEL-N-11-10652-00001 2.5 2.5 air 0.27 0.26 47 45 21 with grilles-between-the-glass PEL-N-11-10694-00001 0.27 0.23 43 45 19 with integral grilles PEL-N-11-10666-00001 0.28 0.23 43 45 18 11/16" AdvancedComfort Low-E IG PEL-N-11-10653-00001 3 3 air 0.27 0.26 47 44 21 with grilles-between-the-glass PEL-N-11-10695-00001 0.27 0.23 42 44 19 with integral grilles PEL-N-11-10667-00001 0.28 0.23 42 44 18 11/16" NaturalSun Low-E IG PEL-N-11-09079-00001 2.5 2.5 air 0.32 0.48 55 57 27 with grilles-between-the-glass PEL-N-11-09701-00001 0.32 0.44 50 57 25 with integral grilles PEL-N-11-09289-00001 0.33 0.44 50 57 11/16" NaturalSun Low-E IG PEL-N-11-09080-00001 3 3 air 0.32 0.47 54 56 27 with grilles-between-the-glass PEL-N-11-09702-00001 0.32 0.43 49 56 25 with integral grilles PEL-N-11-09290-00001 0.33 0.43 49 56 (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY STAR® values are updated to 2015 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative. See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones