Loading...
HomeMy WebLinkAboutA1-02.pdf27" BUILT-IN SUB-ZERO, 2 DRAWER FREEZER BELOW 55"-60" WALL MOUNTED TV 30" WOLF GAS IN- COUNTER RANGE, WOLF CONCEALED HOOD ABOVE WINDOWS TO BE UPDATED WITH PELLA SLIM BLINDS, TYP. BUILT-IN STORAGE BELOW HEARTH WARD ROBE 55"-60" WALL MOUNTED TV EXISTING FIREPLACE, LINER TO BE REPLACED, DECORATIVE FACE TO BE REPLACED. 13' - 2 3/8" 8' - 4 3/8" 37'-7 1/2" 11'-0 1/4" 5'-0 1/2" 6 3/4" 21'-0" 2'-8 1/2" 6'-6 1/2" 1'-5 3/4" 6'-0" 1'-4" 18'-0 3/4" 37'-7 1/2" 3' - 0" E 2' - 0" 2 6' - 0" S RELOCATED GAS LINE TO ACCOMMODATE GRILL 2 DRAWER DISHWASHER EXISTING CONCRETE STRUCTURE BEVERAGE COOLER 12" UNIT ENTRY (6'-8") NIGHTSTANDS 30" WOLF UNDER COUNTER MICROWAVE SINGLE BASIN SINK GUEST COAT CLOSET, WITH MIRROR MOUNTED ON DOOR INTERIOR FOYER INCREASED BY 5" WIDTH 3' - 0" 3 14" SHELVES TALL CHEST 3' - 6" 1 RECYCLING BINS ONE COAT RACK, WALL MOUNTED HOOKS KING SIZE BED PLASTER WALLS 2" ROUNDED CORNER SCULPTURE PODIUM A4.01 1 A4.02 1 3'-0" 3'-0" 2'-0" CONDUIT FOR OXYGEN HOSE, ROUTE FROM CLOSET CABINET TO BEHIND BED 6 1/8" 37'-7 1/2" 8'-4 3/8" 8' - 11 1/2" 8' - 11 1/2" 8' - 0" 8' - 0" RAISE BATHROOM CEILING TO MAX. POSSIBLE, CURRENTLY AT 6'-11" 4 D D A A A C C A A A A B B POSSIBLE WALL MOUNTED READING LIGHT E 16' - 0 3/4" 18'-0 3/4" 8' - 11 1/2" 8' - 11 1/2" 8' - 11 1/2" 8' - 11 1/2" A A A A A A A A A A A A A F G G G CROWN MOLDING DROPPED BEAMS CROWN MOLDING CROWN MOLDING A B B D INTERIOR LIGHTING AT WARDROBES F F F F INTERIOR LIGHTING AT CLOSET B B 7' - 11" UNDER CABINET LIGHTS WITH PLUG MOLDS CMD CMD CARBON MONOXIDE DETECTOR SMOKE DETECTOR CARBON MONOXIDE DETECTOR SMOKE DETECTOR SD SD NOTE: ALL LIGHT FIXTURES TO RECEIVE A FIRE RATED LIGHTING ENCLOSURE WHICH MEETS ASTM E-119, UL263 RECESSED FIXTURE (TYPE A) LINEAR SURFACE FLUORESCENT (TYPE E) RCP LEGEND SINGLE SWITCH D 3 DIMMER SWITCH 3-WAY SWITCH DJ DOOR JAMB SWITCH RECESSED DIRECTIONAL FIXTURE (TYPE B) J JUNCTION BOX M MOTION SENSOR 4 LUTRON 6 SLOT SWITCH 6 LUTRON 4 SLOT SWITCH VENT FAN WALL MOUNTED FIXTURE (TYPE C) LED STRIP FIXTURE (TYPE D) 2.5" RECESSED (TYPE F) PENDANT LIGHT (TYPE G) CMD CARBON MONOXIDE DETECTOR NEW STUD WALLS EXISTING WALLS DEMOLITION LEGEND WALLS TO BE DEMOLISHED 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 122 E. MEADOW DR VILLAGE CENTER, BLDG B, UNIT 2D VAIL, CO 81657 A1.02 PROPOSED - FLOORPLAN & RCP VILLAGE CENTER CONDOMINIUMS Project Number - 1503 04/17/15 PERMIT SET 3/8" = 1'-0" A1.02 1 UNIT 2D - PROPOSED FLOOR PLAN - 27" FRIDGE/ 2 DRAWER FREEZER 3/8" = 1'-0" A1.02 2 UNIT 2D - REFLECTED CEILING PLAN 04/29/15