E1.pdf
Double M Inc Date: 4-28-15 P.O. Box 1462 Gypsum, CO 81637 (970) 376-4862 Residential Electrical Load Calculations Owner: David and Izabel Flowers Address: 1220 West Haven Lane General Lighting Load Square footage:6300 General lighting load:18900 Watts Small appliance:9000 Watts Laundry Circuit:3000 Watts Lighting Load Subtotal:30900 Watts First 3000 @ 100%:3000 Watts 3001 watts to 120,000 watts @ 35%:9765 Watts Over 120,000 watts @ 25%:Watts Lighting Load Total:12765 Watts Cooking Equipment Loads Range: Load @ 100%8000 Watts Dryer load Dryer:Load @ 100%5000 Watts Fixed Appliance Load Dishwasher:2100 Watts Disposal:1200 Watts Trash Compactor:3000 Watts Microwave:3000 Watts Range Hood:600 Watts Refrigerator:1680 Watts Jacuzzi Tub:Watts Steamer:9120 Watts Freezer:840 Watts Central Vac:Watts Insta Hot:Watts Pump:Watts Hot tub:7200 Watts Garage door:720 Watts Sauna 9360 Watts Total:38820 Watts Less than 4 appliance at 100%:Watts More than 4 appliances at 75%:29115 Watts Total:29115 Watts Heating or A/C load which ever is larger Heating unit:5400 Watts A/C units:24000 Watts Heat pump:Watts Heat tape 7200 Watts Largest load:24000 Load @ 100%24000 Watts Largest Motor Load 1200 Watts @ 25%:300 Watts Total load:79180 Watts Total amp draw:329.916667 Amps Service size 400 Amps