HomeMy WebLinkAbout150601 Galatyn Chiller m and e.pdf06/03/15 PROJECT SCOPE Electrical feeder/service evaluate for Chiller replacement Dated: May 31, 2015 Evaluate the existing electrical service at the at the Galatyn Lodge Task Name/Number Task Description 1. Review the existing "MDP" 2. Review the existing chiller sub-switch 3. Evaluate the existing chiller feeder 4. Review new chiller equipment Key Personnel Mitchell Hyra PE@ Peak Design Group LLC Brent Wilson PE@ R and H Mechicanical Key Partners AK Electric personnel; Johnny The existing chiller was fed from a 120/208 volt Siemens Electric 800amp 3-phase 4 wire service panel via a 200amp, 3 pole fused (FRN-R-200 bussman fuses) sub-switch housed within. Feeding the existing chiller equipment, via 3# 3/0 awg wire (see photos 1,2,3 and 4). All the equipment is in good condition and working and shall be reused. The new chiller has a electrical service requirement of 120/208 volt 3-phase with a min circuit ampacity of 127.4 and a recommended over current device of 150 amp.s (see cut-sheet attached) Project Background and Description Technical Task List Key Name List Existing services evaluation New equipment evaluation 06/03/15 Connect to existing 200amp, 3 pole fused (w/FRN-R-200 bussman fuses) sub-switch that fed the existing chiller equipment, via the existing 3# 3/0 awg wire. Located in 120/208 volt Siemens the 800amp 3-phase 4 wire service panel. Add a new 200 amp 3-phase fusible Disconnect switch (fused @150 amp w/FRN-R-150 bussman fuses) at the new chiller location. Located per the NEC It is recommended a new 3 phase 1/0 awg copper feeder be used from said chiller disconnect to the new chiller.(the small has a high Resistance [Ohm/m] Copper (20 °C,68 °F) 0.000323 to min the SYMMETRICAL RMS AMPERES) Note:  The lugs and electrical equipment rating with-in the new chiller are unknown.  The above will provide a SYMMETRICAL RMS AMPERES of less than 10,000 AIC at the chiller equipment lugs.  The RMS AMPs for the above are calculated using an infinite buss up/over/down method with bussman charts and standards wire size resistance [Ohm/m] Copper (20 °C,68 °F).  The engineer has NOT examined the MDP or any other up/down stream electrical devices for soundness or load. Recommended additions or changes 06/03/15 The persons listed below represent their respective organizations related to this project. Approval and authority to proceed must be given by all persons identified below. I approve of the project as identified herein. I give my authority to proceed. _______________________________ Mitchell Hyra I approve of the project as identified herein. I give my authority to proceed. _______________________________ Brent Wilson Approval and Authority to Proceed PE Principal Engineer R&H Mechanical 6/1/15 06/03/15 06/03/15 06/03/15 06/03/15 06/03/15 Unit Report For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Unit Information Tag Name: 25T CH 4.23.15 Model Number: 30RAP025 Condenser Type: Air Cooled Compressor Type: Scroll Nameplate Voltage: 208/230-3-60 V-Ph-Hz Quantity: 1 Manufacturing Source: Charlotte, NC USA Refrigerant: R410A Independent Refrigerant Circuits: 1 Capacity Control Steps: 22 Minimum Capacity: 17.0 % Shipping Weight: 1328 lb Operating Weight: 1242 lb Unit Length: 89 in Unit Width: 41 in Unit Height: 79 in Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Chiller Warranty Information (Note: for US & Canada only) First Year - Parts Only (Standard) Complete Unit Less Hydronic System Years 2-5 Parts Only Ordering Information Part Number Description Quantity 30RAP0255F-02100 Packaged Chiller 1 Base Unit Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point 30RA-900---066 Wind Baffle 1 38AP-900---003 Security Grilles/Hail Guards 1 38AP-900---020 Motormaster® V Low Ambient Kit. Operation down to -20° F (-29° C). 1 38AP-900---009 Low Sound Compressor Blankets 2 30RA-900---005 Vibration Isolation Package 1 Packaged Chiller Builder NACO 3.49j Page 1 of 10 06/03/15 Certified Drawing for 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Packaged Chiller Builder NACO 3.49j Page 2 of 10 06/03/15 Field Wiring Diagram for 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Packaged Chiller Builder NACO 3.49j Page 3 of 10 06/03/15 Summary Performance Report For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM PackagedChillerReport:DoNotEdit; AquaSnapTM Air-Cooled Scroll Chiller Unit Information Tag Name: 25T CH 4.23.15 Model Number: 30RAP025 Quantity: 1 Manufacturing Source: Charlotte, NC USA Refrigerant: R410A Independent Refrigerant Circuits: 1 Shipping Weight: 1328 lb Operating Weight: 1242 lb Unit Length: 89 in Unit Width: 41 in Unit Height: 79 in Chiller Pressure Drop*: 28.6 ft wg *Use Chiller Pressure Drop for sizing pumps. This value includes losses due to chiller piping, fittings, 40 mesh factory supplied strainer and BPHX. Evaporator Information Fluid Type: Propylene Glycol Brine Concentration: 50.0 % Fouling Factor: 0.00010 (hr-sqft-F)/BTU Leaving Temperature: 44.0 °F Entering Temperature: 54.0 °F Fluid Flow: 57.0 gpm Evaporator Pressure Drop*: 20.7 ft wg *Refer to Chiller Pressure Drop for sizing pumps. Condenser Information Altitude: 8500 ft Number of Fans: 2 Total Condenser Fan Air Flow: 19400 CFM Entering Air Temperature: 95.0 °F Integrated Pump Information No Pump Selected Performance Information Cooling Capacity: 21.0 Tons Total Compressor Power: 25.2 kW Total Fan Motor Power: 2.04 kW Total Unit Power (without pump): 27.3 kW Efficiency (without pump): 9.26 EER IPLV: 15.14 EER Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Electrical Information Unit Voltage: 208/230-3-60 V-Ph-Hz Connection Type: Single Point Electrical Electrical Amps Circuit 1 Circuit 2 MCA 127.4 --- MOCP 175.0 --- ICF 363.3 --- Rec Fuse Size 150.0 --- Sound power measured in accordance with ANSI/AHRI Standard 370-2001. Packaged Chiller Builder NACO 3.49j Page 4 of 10 06/03/15 Summary Performance Report For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Evaporator contains a glycol or other secondary coolants for freeze protection with a leaving chilled fluid temperature above 32°F and is certified in accordance with the AHRI Air-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI) when tested with water at Standard Rating Conditions. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Packaged Chiller Builder NACO 3.49j Page 5 of 10 06/03/15 Summary Performance Report For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Unit Parameters Tag Name: 25T CH 4.23.15 Model Number: 30RAP025 Condenser Type: Air Cooled Compressor Type: Scroll Chiller Nameplate Voltage: 208/230-3-60 V-Ph-Hz Quantity: 1 Manufacturing Source: Charlotte, NC USA Refrigerant: R410A Shipping Weight: 1328 lb Operating Weight: 1242 lb Unit Length: 89 in Unit Width: 41 in Unit Height: 79 in 1 - Chiller Height Above Ground 2 - Horizontal Distance From Chiller to Receiver 3 - Receiver Height Above Ground (See Note 3) Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Acoustic Information Table 1. A-Weighted Sound Power Levels (dB re 1 picowatt). See note #1. Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall 100% Load 37 58 68 78 83 84 83 77 67 89 75% Load 37 58 68 78 83 84 83 77 67 89 50% Load 37 58 68 78 83 84 82 77 67 88 25% Load 34 55 65 75 80 81 80 74 64 86 Table 2. A-Weighted Sound Pressure Levels (dB re 20 micropascals) calculated based upon user defined input for dimensions 1, 2 and 3 as shown in above diagram. See note #2 and #3. Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall 100% Load 10 31 40 50 55 56 55 49 40 61 75% Load 10 31 40 50 55 56 55 49 40 61 50% Load 10 30 40 50 55 56 55 49 40 61 25% Load 7 28 37 47 52 53 52 46 37 58 Notes: (1) Measurements performed in accordance with AHRI Standard 370 for air cooled Chillers. (2) Chiller is assumed to be a point source on a reflecting plane. (3) Without user defined input, the default dimensions used to construct Table 2 are as follows: 1 - Chiller Height Above Ground = 0.0 ft 2 - Horizontal Distance From Chiller to Receiver = 30.0 ft 3 - Receiver Height Above Ground = 3.0 ft Packaged Chiller Builder NACO 3.49j Page 6 of 10 06/03/15 Acoustic Summary For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM PackagedChillerReport:DoNotEdit; Please refer to Performance Output Summary or Detailed Performance Report for Acoustic information Packaged Chiller Builder NACO 3.49j Page 7 of 10 06/03/15 Detailed Performance Summary For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM PackagedChillerReport:DoNotEdit; Unit Information Tag Name: 25T CH 4.23.15 Model Number: 30RAP025 Condenser Type: Air Cooled Compressor Type: Scroll Nameplate Voltage: 208/230-3-60 V-Ph-Hz Quantity: 1 Manufacturing Source: Charlotte, NC USA Refrigerant: R410A Capacity Control Steps: 22 Minimum Capacity: 17.0 % Shipping Weight: 1328 lb Operating Weight: 1242 lb Unit Length: 89 in Unit Width: 41 in Unit Height: 79 in Minimum Outdoor Operating Temp: 45 °F Chiller Pressure Drop*: 28.6 ft wg *Use Chiller Pressure Drop for sizing pumps. This value includes losses due to chiller piping, fittings, 40 mesh factory supplied strainer and BPHX. Performance Information Cooling Capacity: 21.0 Tons Total Compressor Power: 25.2 kW Total Fan Motor Power: 2.04 kW Total Unit Power (without pump): 27.3 kW Efficiency (without pump): 9.26 EER Evaporator Information Fluid Type: Propylene Glycol Brine Concentration: 50.0 % Fouling Factor: 0.00010 (hr-sqft-F)/BTU Leaving Temperature: 44.0 °F Entering Temperature: 54.0 °F Fluid Flow: 57.0 gpm Evaporator Pressure Drop*: 20.7 ft wg *Refer to Chiller Pressure Drop for sizing pumps. Condenser Information Altitude: 8500 ft Number of Fans: 2 Total Condenser Fan Air Flow: 19400 CFM Entering Air Temperature: 95.0 °F Integrated Pump Information No Pump Selected Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Electrical Information Unit Voltage: 208/230-3-60 V-Ph-Hz Connection Type: Single Point Electrical Electrical Amps Circuit 1 Circuit 2 MCA 127.4 --- MOCP 175.0 --- ICF 363.3 --- Rec Fuse Size 150.0 --- Packaged Chiller Builder NACO 3.49j Page 8 of 10 06/03/15 Detailed Performance Summary For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Integrated Part Load Value (AHRI) IPLV: 15.14 EER Unit Performance Percent of Full Load Capacity, % 100 75 50 25 Percent of Full Load Power, % 100.0 55.7 31.1 14.9 Unloading Sequence A A A A Cooling Capacity, Tons 23.3 17.5 11.6 5.8 Total Unit Power, kW 27.7 15.4 8.6 4.1 Efficiency, EER 10.08 13.58 16.23 16.91 Evaporator Data Fluid Entering Temperature, °F 54.0 51.5 49.0 46.5 Fluid Leaving Temperature, °F 44.0 44.0 44.0 44.0 Fluid Flow Rate, gpm 55.9 55.9 55.9 55.9 Fouling Factor, (hr-sqft-F)/BTU 0.0001 0.0001 0.0001 0.0001 Condenser Data Entering Air Temperature, °F 95.0 80.0 65.0 55.0 For some 75% operating points, the efficiency may be calculated at a condenser inlet air operating temperature as much as 0.8 degrees higher. Sound power measured in accordance with ANSI/AHRI 370-2001. Evaporator contains a glycol or other secondary coolants for freeze protection with a leaving chilled fluid temperature above 32°F and is certified in accordance with the AHRI Air-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI) when tested with water at Standard Rating Conditions. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Packaged Chiller Builder NACO 3.49j Page 9 of 10 06/03/15 Detailed Performance Summary For 25T CH 4.23.15 Project: ~Untitled1 04/23/2015 Prepared By: Darryl Merkle 10:43AM Unit Parameters Tag Name: 25T CH 4.23.15 Model Number: 30RAP025 Condenser Type: Air Cooled Compressor Type: Scroll Chiller Nameplate Voltage: 208/230-3-60 V-Ph-Hz Quantity: 1 Manufacturing Source: Charlotte, NC USA Refrigerant: R410A Shipping Weight: 1328 lb Operating Weight: 1242 lb Unit Length: 89 in Unit Width: 41 in Unit Height: 79 in 1 - Chiller Height Above Ground 2 - Horizontal Distance From Chiller to Receiver 3 - Receiver Height Above Ground (See Note 3) Accessories and Installed Options Cooler Heater Micro Channel, E-Coat Low Sound Digital Compressor Single Point Wind Baffle Security Grilles/Hail Guards Motormaster® V Low Ambient Kit. Operation down to -20° F (- 29° C). Low Sound Compressor Blankets Vibration Isolation Package Acoustic Information Table 1. A-Weighted Sound Power Levels (dB re 1 picowatt). See note #1. Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall 100% Load 37 58 68 78 83 84 83 77 67 89 75% Load 37 58 68 78 83 84 83 77 67 89 50% Load 37 58 68 78 83 84 82 77 67 88 25% Load 34 55 65 75 80 81 80 74 64 86 Table 2. A-Weighted Sound Pressure Levels (dB re 20 micropascals) calculated based upon user defined input for dimensions 1, 2 and 3 as shown in above diagram. See note #2 and #3. Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall 100% Load 10 31 40 50 55 56 55 49 40 61 75% Load 10 31 40 50 55 56 55 49 40 61 50% Load 10 30 40 50 55 56 55 49 40 61 25% Load 7 28 37 47 52 53 52 46 37 58 Notes: (1) Measurements performed in accordance with AHRI Standard 370 for air cooled Chillers. (2) Chiller is assumed to be a point source on a reflecting plane. (3) Without user defined input, the default dimensions used to construct Table 2 are as follows: 1 - Chiller Height Above Ground = 0.0 ft 2 - Horizontal Distance From Chiller to Receiver = 30.0 ft 3 - Receiver Height Above Ground = 3.0 ft Packaged Chiller Builder NACO 3.49j Page 10 of 10 06/03/15