HomeMy WebLinkAboutLine Diagram.pdfPage 4 of 4 4/23/2015
P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com
4 #10 USE-2/RHW-2
1# 6G Bare Cu
Conductors in Free Air
Inverter w/
Integrated DC Disconnect
SolarEdge SE7600A-US
NEMA 3R
Max AC Output: 32A @ 240V
Located in east side of home
DC Grounding
Electrode Conductor
solid bare #6 Cu
per NEC 250.66(C) Service Panel
Located east side of
home
Line Diagram
Dobyns Residence
3080 Booth Falls Road
Vail, CO 81657
8.84 kW Utility Interactive Photovoltaic
System
Modules: 34 Phono Solar PS260M-20/U
Voc = 38.1 V
Isc = 8.85 A
Optimizers: 34 SolarEdge P300
2 String X 17 Modules
Inverter: SolarEdge SE7600A-US
Operating Voltage: 350V
Operating Current: 26A
Max System Voltage: 500V
Max Output Current: 30A
Tilt Angle: 9.46º
Array Azimuth: 195°
Production: 11.762kWh/yr
Notes:
- See Calculation Sheet for conductor
sizing.
- All conductors are copper unless
otherwise noted.
- Inverter listed (UL-1741) to de-
energize upon loss of utility voltage
per NEC 690.61.
- Inverter has integral ground-fault
protection per NEC 690.5
- 240V 1 Phase Service Panel rating
of 200A (bus rating 200 amp and 200
Main disconnect) to accommodate
40A + 200A = 240A supply (up to
120% of connected power sources
from residential installations per NEC
690.64(B)(2))
Array mounted on roof
34 Phono Solar PS260M-20/U Solar Panels
34 SolarEdge P300 DC Optimizers
Net Meter
On north side
of garage
18
Pass-Thru
Box
Located on
roof
Placard stating
ā€¯Photovoltaic System Connectedā€¯
per Holy Cross specifications
AC
Disconnect
60A adjacent
to meter
+/-25'
¾" C EMT/MC Cable
2 #10 THWN-2
1 #10 THWN-2 G
19 20 34
...
1 2 3
17
...
+/-3'
¾" C EMT/PVC
3 #8 THWN-2
1 #10 THWN-2 G
OR
#8 NM-B w/G
Backfeed
Breaker
40A
2P
240V
07/10/15