HomeMy WebLinkAboutSolar Calculations.pdf Page 1 of 4 4/23/2015 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233/info@activeenergies.com) Site: Dobyns Residence 3080 Booth Falls Road Vail, CO 81657 Equipment: Panels: 34 Phono Solar PS260M-20/U black solar panels @ 260watts Inverter: SolarEdge SE7600A-US + 34 SolarEdge P300 Optimizers Mounting Equipment: Unirac racking system with S5 mounting feet Monitoring: SolarEdge Remote Monitoring Service System Layout: Single Panel = 5.38ft tall X 3.26ft wide Panel Arrangement: 3 rows of 8and 2 rows of 5 panels oriented in the portrait position, mounted flush on the south facing roof Holy Cross electric meter located on east side of home. PV disconnect and inverter to be located adjacent to meter. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Holy Cross Meter, Inverter and PV Disconnect Page 2 of 4 4/23/2015 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Calculations 8.84kW System Size (STC)  34 Phono Solar PS260M-20/U solar modules @ 260watts  35 SolarEdge P300 Optimizers  1 SolarEdge SE7600A-US inverter (2 strings of 17 modules/optimizers)  Fixed array tilt angle: 9.46º  Array azimuth: 195º (where 180º is south)  Estimated annual power production: 11,762kWh Maximum PV System Voltage: 690.7 Voc = 38.1V/module 38.1V x 1 module = 38.1V Temperature correction factor 690.7(A) Temperature Coefficient (Voc) = -0.33%/°K (-60°C (-.0033) = .198% ((.198% x 38.1V) x 1 panels) + 38.1V = 45.6V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 8.85A 8.85A x 1.25 = 11.1A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) 4,420w / 350v = 12.6A per 17 string SE7600A-US inverter limit 23A combined string Inverter Output Circuit Current: 690.8 (A)(3) 32A @ 240V John Wiles, “Photovoltaic Power Systems and the National Electrical Code: Suggested Practices”, 2005, pp. E1-E25. pdf version online at: http://www.nmsu.edu/%7Etdi/Photovoltaics/Codes- Stds/PVnecSugPract.html Page 3 of 4 4/23/2015 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Conductor Sizing Pass Thru Box from Optimizers to Inverter (single string): 4,420w / 350v = 12.6A per 17 string 12.6A x 1.25 = 15.8A #10 USE-2 Table 310.16 40A (90ºC column, see note 240.4(D)) Conduit fill adjustment Table 310.15 (B)(3)(a) Use .8 for 4-6 conductors 40A x .8 = 32A Temperature correction factor Table 310.15 (B)(2)(b) 32A x .77 = 24.6A Inverter to Disconnect to Service Panel: Nameplate maximum continuous output current: 32A @ 240V 32A x 125% = 40A 210.19 (A)(1) #8 THWN-2 Table 310.16 50A (75ºC column) No temperature correction factor No conduit fill adjustment Overcurrent Protection Device 40A two pole breaker Per Manufacturer Specification Conductors may be oversized for voltage drop