HomeMy WebLinkAbout631 A1.0.pdfDEMOLITION NOTES DEMOLITION GENERAL NOTES EXISTING PRODUCE SINK AND ASSOCIATED FLOOR SINK TO REMAIN - PROTECT AS REQUIRED DURING CONSTRUCTION. EXISTING STERILOX UNIT TO REMAIN - PROTECT AS REQUIRED DURING CONSTRUCTION. EXISTING HANDSINK AND ASSOCIATED EQUIPMENT TO REMAIN - PROTECT AS REQUIRED DURING CONSTRUCTION. PROTECT ALL ADJACENT STRUCTURES, FIXTURES, AND FINISHES AS REQUIRED DURING CONSTRUCTION. PROTECT EXISTING COOLER WALK-IN PANELS AND DOORS AS REQUIRED DURING CONSTRUCTION. EXISTING CEILING TO REMAIN - IF NO DROP CEILING EXISTS, PREPARE EXISTING CEILING AND STRUCTURE ABOVE AS REQUIRED FOR NEW EXPANSION - REUSE AND EXTEND EXISTING FRAMING WHERE FEASIBLE. EXISTING FIRE SPRINKLER HEADS TO REMAIN - IF A DROP CEILING MUST BE INSTALLED, RELOCATE FIRE SPRINKLER HEADS TO SERVE NEW CEILING. EXISTING LIGHT FIXTURES TO REMAIN - CLEAN/REPAIR EXISTING FIXTURES AS REQUIRED FOR 'LIKE-NEW' APPEARANCE - IF FIXTURES ARE DAMAGED BEYOND REPAIR - REPLACE WITH NEW TO MATCH EXISTING FIXTURES. REMOVE/RELOCATE/REUSE EXISTING OUTLETS AS REQUIRED TO SERVE PROPOSED SCALE/PRINTER & TABLE TOP WRAPPER - REUSE EXISTING CIRCUITS. NEW/EXISTING SELF-CONTAINED FLOOR MERCHANDISER - PROVIDE POWER AS REQUIRED - EXISTING GREEN A-FRAMES SHALL BE REPLACED BY THE NEW HUSSMAN Q2-SS-45 / 4' SELF-CONTAINED CASE, OTHER FIXTURE MODELS SHALL REMAIN - COORDINATE WITH SAFEWAY PM PRIOR TO REMOVING/RELOCATING LOCATING ANY FIXTURES ON THE SALES FLOOR AREA. A. BOLD GRAPHICS INDICATE EXISTING ITEMS TO BE REMOVED OR RELOCATED; LIGHT GRAPHICS INDICATE EXISTING ITEMS TO REMAIN AND INCLUDE BUT ARE NOT LIMITED TO LIGHTING, STROBES, FIRE EXIT SIGNS, EMERGENCY LIGHTING, P.A. SYSTEM, AND ALL LIFE SAFETY EQUIPMENT. B. ALL DAMAGE TO (E) AREAS TO REMAIN SHALL BE REPAIRED AND/OR PATCHED TO PROVIDE A SEAMLESS, LIKE NEW APPEARANCE IN SURFACE FINISH. C. REPLACED & REMOVED ITEMS: ANY ITEMS NOT TO BE REUSED ARE TO BE STORED OR DISPOSED OF AS DIRECTED BY SAFEWAY. D. G.C. TO COORDINATE WITH SAFEWAY TO DETERMINE WHAT ITEMS THAT WILL BE REMOVED SHALL BE SALVAGED FOR SAFEWAY'S REUSE OR DISPOSED OF PROPERLY. G.C. SHALL COORDINATE WITH SAFEWAY ON STORAGE OF ITEMS THAT WILL BE SALVAGED. MENTS, RATION ED TO D WITHIN TCH THE WALL SURFACES. THIS TRACTOR: ERS IN PLACE ORK. WITH THE G DURING RACTORS T EXISTING CONCRETE SLAB TO REMAIN - SEE DRAWING 01/A2.0. REMOVE PORTION OF EXISTING CONCRETE SLAB AS REQUIRED FOR NEW UNDERGROUND PLUMBING. COORDINATE WITH PROPOSED LOCATIONS ON DRAWING 01/A2.0. REMOVE / RELOCATE EXISTING FIXTURING, SHELVING, ETC. G.C. TO COORDINATE WITH SAFEWAY ON ANY SALVAGING / STORAGE OF (E) FIXTURES OR DISPOSAL AS DIRECTED. ELECTRICAL GENERAL NOTES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES HAVING JURISDICTION. 2. THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF HIS WORK. 3. CONTRACTOR SHALL VISIT THE SITE AND EXAMINE CONDITIONS OF THE PREMISES AND THE CHARACTER AND EXTENT OF WORK REQUIRED PRIOR TO BIDDING. ANY DIFFICULTIES IN COMPLYING WITH THE DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE BIDDING. 4. ALL MATERIAL SHALL BE NEW AND BEAR THE UL LABEL LISTED APPROVAL FOR ITS INSTALLED APPLICATION. 5. PROVIDE "LOCKING" TYPE DEVICES ON ALL CIRCUIT BREAKERS CONNECTED TO EMERGENCY AND NIGHT LIGHTING, SIGNS, FIRE ALARM, AND SECURITY SYSTEMS. 6. ALL SWITCHES, DUPLEX RECEPTACLES, AND TELEPHONE OUTLETS TO BE FLUSH MOUNTED, THROUGHOUT UNLESS OTHERWISE NOTED. 7. ELECTRICAL PLANS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS. 8. ALL WORK SHALL BE DONE AT SUCH TIMES AND IN SUCH A MANNER AS WILL LEAST INTERFERE WITH THE MAINTENANCE AND OPERATION OF ALL RELATED OR AFFECTED SYSTEMS. ALL POWER OUTAGES SHALL BE COORDINATED WITH OWNER. 9. ALL EMPTY CONDUIT RUNS IN EXCESS OF 10 FT. SHALL BE PROVIDED WITH A PULL WIRE OR FISH TAPE/CORD. 10. THE CONTRACTOR SHALL GUARANTEE ALL HIS WORK AND MATERIALS FOR A MINIMUM PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER. 11. PROVIDE A #10 NEUTRAL CONDUCTOR FOR ALL MULTIWIRE RECEPTACLE BRANCH CIRCUITS. 12. RECEPTACLES ON SEPARATE CIRCUITS SHALL BE RATED 20 AMP, 120 VOLT. 13. WIRE AND CABLE SHALL BE COPPER, TYPE THHN/THWN, MINIMUM #12 AWG. SEE SPECIFICATIONS FOR EXCEPTIONS. 14. PANELBOARD DIRECTORIES SHALL BE UPDATED AND TYPED TO REFLECT ALL WORK DONE AS PART OF THIS PROJECT. 15. ALL NEW BRANCH CIRCUITS SHALL BE EQUIPPED WITH A MINIMUM #12 AWG GREEN EQUIPMENT GROUND CONDUCTOR. 16. ALL BUILDING WIRING SHALL BE RUN IN CONDUIT. CONDUIT RUN UNDERGROUND OR BELOW SLAB SHALL BE PVC SCHEDULE 40. INTERIOR CONDUIT SHALL BE EMT. EXPOSED EXTERIOR CONDUIT SHALL BE IMC OR RMC. 17. FOR IG RECEPTACLES, PROVIDE 2#12 GREEN GROUND WIRES IN BRANCH CIRCUIT BACK TO PANELBOARD. ARCHITECT: OWNER: THE DIMENSION GROUP 5600 SOUTH QUEBEC STREET, SUITE 310B GREENWOOD VILLAGE, CO 80111 ARCHITECT OF RECORD: ALEXANDRA MATIS, NCARB, LEED AP BD+C EMAIL: amatis@dimensiongrp.com CONTACT: TANNER KINDE, LEED AP BD+C EMAIL: tkinde@dimensiongrp.com PHONE: (720) 536-3180 X18 SAFEWAY, A DELAWARE COMPANY, INC. DENVER DIVISION 6900 S. YOSEMITE STREET CENTENNIAL, CO 80112 PHONE: (303) 843-7560 FAX: (303) 843-7916 PM: DAN FLORI EMAIL: dan.flori@safeway.com ELECTRICAL / PLUMBING ENGINEER: THE DIMENSION GROUP 5600 SOUTH QUEBEC STREET, SUITE 310B GREENWOOD VILLAGE, CO 80111 ENGINEER OF RECORD: AFSAR HASAN, P.E. EMAIL: ahasan@dimensiongrp.com CONTACT: JOSH GUNLOCK, E.I. EMAIL: jgunlock@dimensiongrp.com PHONE: (720) 536-3180 PROJECT DIRECTORY DEMOLITION FLOOR PLAN 01 1/4" = 1'-0" DEMOLITION CEILING PLAN 02 1/4" = 1'-0" 9'-5" 12'-2" 21'-7" PREPARE STRUCTURE ABOVE FOR NEW LAY-IN CEILING E E E D D D D E E E E E E 9'-5" DEMO EXISTING F.S. - BOTH SINKS TO DRAIN INDIRECTLY TO OTHER EXISTING F.S. REMOVE AND RELOCATE EXISTING PRODUCE SINK AS INDICATED REMOVE AND RELOCATE EXISTING HAND SINK REMOVE EXISTING COOLER DOOR AND REPLACE WITH NEW DOUBLE DOOR (HUSSMAN OR EQUAL) OVERALL PLAN 03 1/16" = 1'-0" LIMIT OF WORK 5(029((;,67,1*0(5&+$1',6(5$1'5(3/$&(:,7+1(: NEW MERCHANDISER - VERIFY W/ SAFEWAY PM REGARDING LOCATION - REWORK CIRCUIT OF EXISTING FLOOR BOX OUTLET TO MATCH 110V NEEDS OF NEW SELF-CONTAINED CASE E E E D D D D E E E E E E N N N N T:\DG\Safeway - Denver Division\Fresh Cut Fruit Roll-out\C5-075 - Safeway Store #0631 (Vail, CO)\04 Architectural\Current CD's\C5-075 - Safeway #0631 - A1.0 - Layout.dwg Jun 10, 2015 - 7:01am tkinde OVERALL AND DEMOLITION PLANS A1.0 SHEET NO. SHEET TITLE C5-075 CHECKED BY: DRAWN BY: PROJECT NO. BUILDING DEPT: O.T.B.: OWNER: STAMP REVISIONS TM 05/26/2015 SUBMITTAL DATES SAFEWAY STORE #0631 VAIL, CO 2131 NORTH FRONTAGE ROAD ACTIVITY NO: #05-0631-000-0017 OWNER REVISIONS (ADDENDUM 1) 06/03/2015 01 06.09.2015 OWNER REVISIONS (ADDENDUM 1) 06/09/2015 02 01 01 02 02 STAMP 07/31/15