HomeMy WebLinkAbout631 A1.0.pdfDEMOLITION NOTES
DEMOLITION GENERAL NOTES
EXISTING PRODUCE SINK AND ASSOCIATED FLOOR SINK TO REMAIN - PROTECT AS REQUIRED
DURING CONSTRUCTION.
EXISTING STERILOX UNIT TO REMAIN - PROTECT AS REQUIRED DURING CONSTRUCTION.
EXISTING HANDSINK AND ASSOCIATED EQUIPMENT TO REMAIN - PROTECT AS REQUIRED
DURING CONSTRUCTION.
PROTECT ALL ADJACENT STRUCTURES, FIXTURES, AND FINISHES AS REQUIRED DURING
CONSTRUCTION.
PROTECT EXISTING COOLER WALK-IN PANELS AND DOORS AS REQUIRED DURING
CONSTRUCTION.
EXISTING CEILING TO REMAIN - IF NO DROP CEILING EXISTS, PREPARE EXISTING CEILING AND
STRUCTURE ABOVE AS REQUIRED FOR NEW EXPANSION - REUSE AND EXTEND EXISTING
FRAMING WHERE FEASIBLE.
EXISTING FIRE SPRINKLER HEADS TO REMAIN - IF A DROP CEILING MUST BE INSTALLED,
RELOCATE FIRE SPRINKLER HEADS TO SERVE NEW CEILING.
EXISTING LIGHT FIXTURES TO REMAIN - CLEAN/REPAIR EXISTING FIXTURES AS REQUIRED FOR
'LIKE-NEW' APPEARANCE - IF FIXTURES ARE DAMAGED BEYOND REPAIR - REPLACE WITH NEW
TO MATCH EXISTING FIXTURES.
REMOVE/RELOCATE/REUSE EXISTING OUTLETS AS REQUIRED TO SERVE PROPOSED
SCALE/PRINTER & TABLE TOP WRAPPER - REUSE EXISTING CIRCUITS.
NEW/EXISTING SELF-CONTAINED FLOOR MERCHANDISER - PROVIDE POWER AS REQUIRED -
EXISTING GREEN A-FRAMES SHALL BE REPLACED BY THE NEW HUSSMAN Q2-SS-45 / 4'
SELF-CONTAINED CASE, OTHER FIXTURE MODELS SHALL REMAIN - COORDINATE WITH
SAFEWAY PM PRIOR TO REMOVING/RELOCATING LOCATING ANY FIXTURES ON THE SALES
FLOOR AREA.
A. BOLD GRAPHICS INDICATE EXISTING ITEMS TO BE REMOVED OR RELOCATED;
LIGHT GRAPHICS INDICATE EXISTING ITEMS TO REMAIN AND INCLUDE BUT
ARE NOT LIMITED TO LIGHTING, STROBES, FIRE EXIT SIGNS, EMERGENCY
LIGHTING, P.A. SYSTEM, AND ALL LIFE SAFETY EQUIPMENT.
B. ALL DAMAGE TO (E) AREAS TO REMAIN SHALL BE REPAIRED AND/OR
PATCHED TO PROVIDE A SEAMLESS, LIKE NEW APPEARANCE IN SURFACE
FINISH.
C. REPLACED & REMOVED ITEMS: ANY ITEMS NOT TO BE REUSED ARE TO BE
STORED OR DISPOSED OF AS DIRECTED BY SAFEWAY.
D. G.C. TO COORDINATE WITH SAFEWAY TO DETERMINE WHAT ITEMS THAT WILL
BE REMOVED SHALL BE SALVAGED FOR SAFEWAY'S REUSE OR DISPOSED OF
PROPERLY. G.C. SHALL COORDINATE WITH SAFEWAY ON STORAGE OF ITEMS
THAT WILL BE SALVAGED.
MENTS,
RATION
ED TO
D WITHIN
TCH THE
WALL
SURFACES.
THIS
TRACTOR:
ERS
IN PLACE
ORK.
WITH THE
G DURING
RACTORS
T
EXISTING CONCRETE SLAB TO REMAIN - SEE DRAWING 01/A2.0.
REMOVE PORTION OF EXISTING CONCRETE SLAB AS REQUIRED FOR NEW
UNDERGROUND PLUMBING. COORDINATE WITH PROPOSED LOCATIONS ON DRAWING
01/A2.0.
REMOVE / RELOCATE EXISTING FIXTURING, SHELVING, ETC. G.C. TO COORDINATE
WITH SAFEWAY ON ANY SALVAGING / STORAGE OF (E) FIXTURES OR DISPOSAL AS
DIRECTED.
ELECTRICAL GENERAL NOTES
1.
ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL
CODE AND ALL LOCAL CODES HAVING JURISDICTION.
2. THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL PERMITS AND PAY SUCH FEES AS
MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY
FOR THE COMPLETION OF HIS WORK.
3.
CONTRACTOR SHALL VISIT THE SITE AND EXAMINE CONDITIONS OF THE PREMISES AND
THE CHARACTER AND EXTENT OF WORK REQUIRED PRIOR TO BIDDING. ANY
DIFFICULTIES IN COMPLYING WITH THE DRAWINGS AND SPECIFICATIONS SHALL BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE BIDDING.
4.
ALL MATERIAL SHALL BE NEW AND BEAR THE UL LABEL LISTED APPROVAL FOR ITS
INSTALLED APPLICATION.
5.
PROVIDE "LOCKING" TYPE DEVICES ON ALL CIRCUIT BREAKERS CONNECTED TO
EMERGENCY AND NIGHT LIGHTING, SIGNS, FIRE ALARM, AND SECURITY SYSTEMS.
6. ALL SWITCHES, DUPLEX RECEPTACLES, AND TELEPHONE OUTLETS TO BE FLUSH
MOUNTED, THROUGHOUT UNLESS OTHERWISE NOTED.
7. ELECTRICAL PLANS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS.
8.
ALL WORK SHALL BE DONE AT SUCH TIMES AND IN SUCH A MANNER AS WILL LEAST
INTERFERE WITH THE MAINTENANCE AND OPERATION OF ALL RELATED OR AFFECTED
SYSTEMS. ALL POWER OUTAGES SHALL BE COORDINATED WITH OWNER.
9. ALL EMPTY CONDUIT RUNS IN EXCESS OF 10 FT. SHALL BE PROVIDED WITH A PULL
WIRE OR FISH TAPE/CORD.
10.
THE CONTRACTOR SHALL GUARANTEE ALL HIS WORK AND MATERIALS FOR A MINIMUM
PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER.
11. PROVIDE A #10 NEUTRAL CONDUCTOR FOR ALL MULTIWIRE RECEPTACLE BRANCH
CIRCUITS.
12.
RECEPTACLES ON SEPARATE CIRCUITS SHALL BE RATED 20 AMP, 120 VOLT.
13. WIRE AND CABLE SHALL BE COPPER, TYPE THHN/THWN, MINIMUM #12 AWG. SEE
SPECIFICATIONS FOR EXCEPTIONS.
14. PANELBOARD DIRECTORIES SHALL BE UPDATED AND TYPED TO REFLECT ALL WORK
DONE AS PART OF THIS PROJECT.
15. ALL NEW BRANCH CIRCUITS SHALL BE EQUIPPED WITH A MINIMUM #12 AWG GREEN
EQUIPMENT GROUND CONDUCTOR.
16.
ALL BUILDING WIRING SHALL BE RUN IN CONDUIT. CONDUIT RUN UNDERGROUND OR
BELOW SLAB SHALL BE PVC SCHEDULE 40. INTERIOR CONDUIT SHALL BE EMT.
EXPOSED EXTERIOR CONDUIT SHALL BE IMC OR RMC.
17. FOR IG RECEPTACLES, PROVIDE 2#12 GREEN GROUND WIRES IN BRANCH CIRCUIT
BACK TO PANELBOARD.
ARCHITECT:
OWNER:
THE DIMENSION GROUP
5600 SOUTH QUEBEC STREET, SUITE 310B
GREENWOOD VILLAGE, CO 80111
ARCHITECT OF RECORD: ALEXANDRA MATIS, NCARB, LEED AP BD+C
EMAIL: amatis@dimensiongrp.com
CONTACT: TANNER KINDE, LEED AP BD+C
EMAIL: tkinde@dimensiongrp.com
PHONE: (720) 536-3180 X18
SAFEWAY, A DELAWARE COMPANY, INC.
DENVER DIVISION
6900 S. YOSEMITE STREET
CENTENNIAL, CO 80112
PHONE: (303) 843-7560
FAX: (303) 843-7916
PM: DAN FLORI
EMAIL: dan.flori@safeway.com
ELECTRICAL
/ PLUMBING
ENGINEER:
THE DIMENSION GROUP
5600 SOUTH QUEBEC STREET, SUITE 310B
GREENWOOD VILLAGE, CO 80111
ENGINEER OF RECORD: AFSAR HASAN, P.E.
EMAIL: ahasan@dimensiongrp.com
CONTACT: JOSH GUNLOCK, E.I.
EMAIL: jgunlock@dimensiongrp.com
PHONE: (720) 536-3180
PROJECT DIRECTORY
DEMOLITION FLOOR PLAN
01 1/4" = 1'-0"
DEMOLITION CEILING PLAN
02 1/4" = 1'-0"
9'-5" 12'-2"
21'-7"
PREPARE STRUCTURE
ABOVE FOR NEW LAY-IN
CEILING
E
E
E
D
D
D
D E E
E E E
E
9'-5"
DEMO EXISTING F.S. - BOTH
SINKS TO DRAIN INDIRECTLY
TO OTHER EXISTING F.S.
REMOVE AND RELOCATE
EXISTING PRODUCE SINK AS
INDICATED
REMOVE AND
RELOCATE
EXISTING HAND
SINK
REMOVE EXISTING COOLER DOOR
AND REPLACE WITH NEW DOUBLE
DOOR (HUSSMAN OR EQUAL)
OVERALL PLAN
03 1/16" = 1'-0"
LIMIT OF WORK
5(029((;,67,1*0(5&+$1',6(5$1'5(3/$&(:,7+1(:
NEW MERCHANDISER - VERIFY W/
SAFEWAY PM REGARDING LOCATION -
REWORK CIRCUIT OF EXISTING FLOOR
BOX OUTLET TO MATCH 110V NEEDS
OF NEW SELF-CONTAINED CASE
E
E
E
D
D
D
D E E
E E E
E
N
N N
N
T:\DG\Safeway - Denver Division\Fresh Cut Fruit Roll-out\C5-075 - Safeway Store #0631 (Vail, CO)\04 Architectural\Current CD's\C5-075 - Safeway #0631 - A1.0 - Layout.dwg Jun 10, 2015 - 7:01am tkinde
OVERALL AND
DEMOLITION
PLANS
A1.0
SHEET NO.
SHEET TITLE
C5-075
CHECKED BY:
DRAWN BY:
PROJECT NO.
BUILDING DEPT:
O.T.B.:
OWNER:
STAMP
REVISIONS
TM
05/26/2015
SUBMITTAL
DATES
SAFEWAY STORE #0631
VAIL, CO
2131 NORTH FRONTAGE ROAD
ACTIVITY NO: #05-0631-000-0017
OWNER REVISIONS (ADDENDUM 1)
06/03/2015
01
06.09.2015
OWNER REVISIONS (ADDENDUM 1)
06/09/2015
02
01
01
02
02
STAMP
07/31/15