Loading...
HomeMy WebLinkAboutA102A.1B.pdfREF. UPUP UPUP 1 2 3 4 5 6 7 8 F G H J K J.2 2.4 2.7 1.1 1.6 0.7 1.5 F.4 PRE-MANUFACTURED HEADWALL PRE-MANUFACTURED HEADWALL A-T A-T HAMPER FIRE VALVE STORAGE TEMP ICU 219 (ISOLATION) TEMP ICU 218 CONTROL STATION ANTE / ALCOVE H-- Q-- TEMP ICU 217 TEMP ICU 216 TEMP ICU NEGATIVE PRESSURE 224 TEMP ICU 223 PATCH AND REPAIR EXISTING FLOOR. MATCH EXISTING INTEGRAL COVE BASE W/ EXISTING COLOR AND FINISH. A102A.1B 2 INSTALL SEAMLESS FLOOR W/ INTEGRAL COVE BASE PAINT ALL WALLS H-- 1. 2. A-- 4 5 6 H J K J.2 PRE-MANUFACTURED HEADWALL PRE-MANUFACTURED HEADWALL A-T A-T HAMPER FIRE VALVE STORAGE TEMP ICU 219 (ISOLATION) TEMP ICU 218 CONTROL STATION ANTE / ALCOVE H--Q-- PATCH AND REPAIR EXISTING FLOOR. MATCH INTEGRAL COVE BASE W/ EXISTING COLOR AND FINISH. A612A.1B 3 2 1 4 A612A.1B 5 INSTALL SEAMLESS FLOOR W/ INTEGRAL COVE BASE 8'-0" 3'-3" 4 7/8" PAINT PAINT PAINT H-- REMOVE + REPLACE FLOOR, BASE, CEILING AS REQUIRED FOR NEW INSTALLATION. FINISH TO MATCH EXISTING. FLOORING & BASE TO MATCH CORRIDOR (EXTEND FLOOR & BASE). PAINT TO MATCH COORIDOR. A-- SMOKE RESISTANT WALL INSTALL NEW VCT FLOORING W/ 4" RESILIENT COVE BASE. PAINT ALL WALLS. *ELEVATIONS MIRRORED FOR RM 218 GENERAL NOTES: 1. ALL DIMENSIONS ARE GIVEN TO FINISHED FACE OF SURFACES, CENTERLINES OF DOUBLE DOORS, INTERIOR WINDOWS AND FIXTURES, OR HINGE SIDE OF SINGLE DOORS, U.N.O. 2. WHEN TWO DIFFERENT PARTITION TYPES APPEAR ADJACENT TO EACH OTHER, THEIR FINISHED WALL SURFACES MUST ALIGN UNLESS OTHERWISE NOTED. 3. PARTITION TYPE DESIGNATION SHALL BE CONTINUOUS UNTIL NOTED, OTHERWISE; CHANGES OCCUR AT WALL INTERSECTIONS AND/ORSTRUCTURAL ELEMENTS. 4. A - B DENOTES PARTITION TYPE. REFER TO SHEET A600A.1B 5. WHERE A RATED PARTITION IS INDICATED AND WHERE A RATING HAS BEEN GIVEN TO A FLOOR/DECK ALL PENETRATIONS MUST BE PROPERLY FIRE/SMOKE SEALED WITH A U.L. RATED FIRE STOPPING ASSEMBLY PER THE ASSIGNED RATING REQUIREMENTS. 6. AT ALL COLUMNS SHOWN FURRED OUT, USE PARTITION TYPE Q-- UNLESS OTHERWISE NOTED. 7. FOR CURVED/ARCHED WALLS PROVIDE STUD FRAMING PER UNITED STATES GYPSUM (USG) RECOMMENDATIONS PER GYPSUM BOARD THICKNESS. 8. REFER TO CODE COMPLIANCE PLANS G112A.1B FOR GENERAL SMOKE AND/OR FIRE RATING INFORMATION AND SPECIAL STRUCTURAL FIRE PROOFING AREAS. 9. REFER TO "FIRE RESISTANCE DESIGN MANUAL," LATEST EDITION PUBLISHED BY THE GYPSUM ASSOCIATION FOR ADDITIONAL INFORMATION. THE DESIGN MANUAL'S GENERAL EXPLANATORY NOTES PERMIT MODIFICATIONS AND SUBSTITUTIONS WITHOUT DEGRADING THE FIRE RESISTANT RATING, RESULTING FROM INCREASING STUD DEPTHS, STUD GAUGES, WALLBOARD THICKNESS, NUMBER OF LAYERS, AND CHASE WALL DIMENSIONS. 10. AT ALL STRUCTURAL STUD FRAMED EXTERIOR WALL CONDITIONS, INTERIOR FINISH GYP BD (5/8" TYPE "X") SHALL EXTEND CONTINUOUS FROM FLOOR TO STRUCTURE ABOVE AT ALL LEVELS. 11. MEET OR EXCEED THE PARTITION TYPE REQUIREMENTS INDICATED. 12. USE DIRECT ATTACHED SYSTEMS FOR UL TESTED FIRE RATED WALLBOARD SYSTEMS. 13. REFER TO THE LIFE SAFETY PLANS AND FLOOR PLANS FOR PARTITION TYPE LOCATIONS. ALL NEW WALLS TO BE TYPE A - T UNLESS OTHERWISE NOTED. 14. WATER RESISTANT GYPSUM BOARD SHALL BE USED IN LIEU OF STANDARD GYPSUM BOARD AT WALLS WITH TILE OR STONE VENEER FINISH. AT WET WALLS USE CEMENTITIOUS BACKER IN LIEU OF STANDARD GYPSUM BOARD. 15. SEE SPECIFIC DETAIL DRAWINGS AND SPECIFICATIONS FOR OFFSET AT THE TOP OF THE PARTITION, PLAN CONFIGURATIONS AND PROJECT CONDITIONS. 16. PROVIDE BLOCKING AND SUPPORT FOR ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES. 17. AT ALL PARTITION TYPES WHERE THE GYPSUM BOARD DOES NOT EXTEND TO STRUCTURE ABOVE PROVIDE 20 GA STUD DIAGONAL BRACING ON ALTERNATE SIDES OF PARTITION TO STRUCTURE AT 72" O.C. MAXIMUM. 18. AT ALL DOOR FRAMES AND CASED OPENINGS 48" WIDE OR LESS PROVIDE (2) 20 GA STUDS FULL HEIGHT TO STRUCTURE EACH SIDE. AT ALL DOOR FRAMES AND CASED OPENINGS LARGER THAN 48" WIDE AND ALL LEAD LINED DOORS PROVIDE (2) 16 GA STUDS EACHSIDE WITH 16 GA FRAMED BOX HEADER. 19. PATCH EXISTING FIRE PROOFING AS REQUIRED TO CONFORM TO FIRE RATING REQUIREMENTS. VERIFY EXTENT OF PATCHING. KEYNOTES 1. DUCT TO ROOF TOP EXHAUST FAN 2. OUTSIDE AIR INTAKE 000 4' 8' 16' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/8" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 7/6/2015 5:05:15 PM A102A.1B Checker Author ARCHITECTURAL FLOOR PLAN & ENLARGED PLAN, LEVEL 02 VAIL VALLEY MEDICAL CENTER 181 WEST MEADOW DRIVE VAIL, CO TEMPORARY ICU ROOMS 218 & 219 HII-1302604 100% CONSTRUCTION DOCUMENTS 07/08/2015 MEP: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 201, Denver, CO 80202 720.407.6002 1/8" = 1'-0" 1 SECOND FLOOR PLAN - PHASE 1B 1/4" = 1'-0" 2 ENLARGED SECOND FLOOR PLAN 07/31/15