Loading...
HomeMy WebLinkAboutA402A.1B.pdfS O2 1 2 3 4 5 6 7 8 F G H J K 2.4 2.7 1.1 1.6 0.7 1.5 F.4 8' - 0" 8' - 0" 9' - 0" 9' - 0" TEMP ICU 219 (ISOLATION) TEMP ICU 218 CONTROL STATION ANTE / ALCOVE STORAGE TEMP ICU 217 TEMP ICU 216 TEMP ICU NEGATIVE PRESSURE 224 TEMP ICU 223 8' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 9' - 0" A402A.1B 2 REFLECTED CEILING PLAN LEGEND SUSPENDED CEILING GRID SUPPLY AIR DIFFUSER RETURN AIR DIFFUSER EXHAUST AIR DIFFUSER SPEAKER FIRE ALARM REMOTE INDICATOR LIGHT NURSE CALL DOME LIGHT NURSE CALL LOCATOR RECEIVERS COVE LIGHTING PROCEDURE LIGHT PENDANT LIGHT FIXTURE IN CEILING COFFER RECESSED DOWN LIGHT DIRECTIONAL RECESSED DOWN LIGHT WALL SCONCE WALL MOUNTED LIGHT FIXTURE WT-3 OXYGEN SUPPLY HOSE DROP SUSPENDED LIGHT FIXTURE (DIRECT / INDIRECT) 4'-0" SUSPENDED LIGHT FIXTURE (DIRECT / INDIRECT) SUSPENDED GYPSUM BOARD CEILING, UNLESS OTHERWISE NOTED CEILING HEIGHT ABOVE FINISHED FLOOR 24" X 48" FLUORESCENT LIGHT FIXTURE FLUORESCENT UNDERCABINET TASK LIGHT FIRE ALARM DEVICE (STROBE, HORN, CHIME, OR COMBO) REFER TO ENGINEERING DRAWINGS. WT-3 DUAL ROLLER SHADE, MOTORIZED OPERATION LIFT/ CURTAIN TRACK 12" x 48" FLUORESCENT GRID MTD RECESSED WALL WASH 2' X 4' GRID MOUNTED LIGHT FIXTURE 2' X 2' GRID MOUNTED LIGHT FIXTURE RADIANT PANEL HEATER SMOKE / FLAME, OR THERMAL DETECTOR: REFER TO ENGINEERING DRAWINGS. X'-X" F S R 2x4 2x2 BREAK GRID AT LOCATION INDICATED TO ALIGN AS SHOWN BR OPEN TO STRUCTURE OTS EXIT SIGN KEYNOTES 1. ALL CEILINGS SHALL BE AT 8'-0" UNO 2. EXISTING GRID TO REMAIN 3. REPAIR GRID AND ACOUSTICAL TILE FOR COMPLETE INSTALL 4. INSTALL SCRUBBABLE HEALTH ZONE TILES 4 5 6 H J K TEMP ICU 219 (ISOLATION) TEMP ICU 218 CONTROL STATION ANTE / ALCOVE STORAGE INSTALL CUBICLE CURTAIN TRACK (CURTAINS BY OWNER). PROVIDE BLOCKING AS REQ'D REPAIR GRID REPAIR GRID 3. 2. 4. 4. EXTEND GRID, NEW CEILING TILE TO MATCH EXISTING CUBICLE CURTAIN TRACK TO REMAIN. REMOVE AND REPLACE 2X2 ACT GRID W/ LAY-IN TILES 3. 000 4' 8' 16' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/8" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 7/6/2015 5:06:47 PM A402A.1B Checker Author ARCHITECTURAL REFLECTED CEILING PLAN, LEVEL 02 VAIL VALLEY MEDICAL CENTER 181 WEST MEADOW DRIVE VAIL, CO TEMPORARY ICU ROOMS 218 & 219 HII-1302604 100% CONSTRUCTION DOCUMENTS 07/08/2015 MEP: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 201, Denver, CO 80202 720.407.6002 1/8" = 1'-0" 1 SECOND FLOOR RCP - PHASE 1B 1/4" = 1'-0" 2 SECOND FLOOR RCP - PHASE 1B 07/31/15