HomeMy WebLinkAboutAD102A.1B.pdfREF. UPUP 1 2 3 4 5 6 7 8 F G H J K J.2 2.4 2.7 1.1 1.6 0.7 1.5 F.4 8 TEMP ICU 219 (ISOLATION) TEMP ICU 218 10. 7. 7. 1. 1. TEMP ICU 217 TEMP ICU 216 TEMP ICU 223 TEMP ICU NEGATIVE PRESSURE 224 12. 8. 13. 11. 3. 2. 3. 3. 4. 4. 3. 2. 2. 2. 5. 5. 5. 5. 6. REMOVE + REPLACE FLOOR, BASE, CEILING AS REQUIRED FOR NEW INSTALLATION. FINISH TO MATCH EXISTING. 6. 9. GENERAL DEMOLITION NOTES: LEGEND: DOOR TO BE REMOVED PARTITION TO BE REMOVED 1. DASHED LINES INDICATE ITEMS TO BE REMOVED. DEMOLITION OF WALLS INCLUDES ALL DOORS, WINDOWS AND OTHER ITEMS LOCATED WITHIN THE WALL TO BE REMOVED UNLESS NOTED OTHERWISE. RE: STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR EXISTING UTILITIES 2. FADED LINES INDICATE ITEMS TO REMAIN. 3. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONSTRUCTION RELATED CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION. 4. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO DEPARTMENTS OR AREAS THAT ARE IN OPERATION AND SERVED BY SUCH SERVICES. COORDINATE ALL DISRUPTIONS OR DISCONTINUATIONS OF UTILITIES AND SERVICES WITH OWNER. 5. ALL FURNISHINGS AND MOVABLE EQUIPMENT IN DEMOLITION/CONSTRUCTION AREA SHALL BE REMOVED/RELOCATED BY OWNER PRIOR TO START OF DEMOLITION. 6. PATCH CORRIDOR WALLS AND RAILINGS TO MATCH EXISTING ADJACENT CONSTRUCTION, PATCH ALL EXISTING WALLS, CEILINGS AND FLOOR TO REMAIN AFTER DEMOLITION IS COMPLETE. COORDINATE EXTENT OF SELECTIVE DEMOLITION WITH PROJECT SEQUENCING PLANS AND WITH OTHER TRADES. PATCH WALL BOXES AND OTHER WALL/CEILING OPENINGS WHEREVER FIXTURES/OUTLETS ARE BEING REMOVED AND WALLS ARE TO REMAIN. 7. 8. REVIEW DEMOLITION AND PENETRATIONS THROUGH EXISTING STRUCTURE WITH AS-BUILT STRUCTURAL DRAWINGS WHERE POTENTIAL OF ENCOUNTERING LOADED/STRUCTURAL BEAMS/JOISTS/COLUMNS EXIST. 9. 10. CONTRACTOR TO COORDINATE I.C.R.A. (INFECTION CONTROL RISK ASSESSMENT) PLAN WITH OWNER PRIOR TO COMMENCEMENT OF EACH PHASE/SUB-PHASE. 11. DEMOLITION WORK SHALL NOT REDUCE INTEGRITY OF STRUCTURE TO REMAIN NOR OF FIRE- PROOFING/SEPARATION. MAINTAIN STRUCTURAL AND LIFE SAFETY INTEGRITY IN AREAS OF WORK AT ALL TIMES. 12. VERIFY ALL ELECTRICAL AND PLUMBING REQUIREMENTS PRIOR TO REMOVING ANY EQUIPMENT. 13. PROVIDE SIGNAGE FOR TEMPORARY CIRCULATION AND EGRESS PATHS DURING DEMOLITION. 14. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DRAWINGS FOR OTHER DEMOLITION WORK AND WORK TO REMAIN IN PLACE, REQUIRED FOR EACH CONSTRUCTION SEQUENCE. 15. NOTIFY OWNER AND ARCHITECT IMMEDIATELY IF HAZARDOUS MATERIALS ARE ENCOUNTERED. ASBESTOS ABATEMENT (OR REMOVAL) TO BE PROVIDED BY OWNER UNDER SEPARATE CONTRACT. COORDINATE WITH GENERAL CONTRACTOR FOR TIMING OF DEMOLITION IN RELATION TO ABATEMENT TO WORK AT EACH CONSTRUCTION SEQUENCE AREA. 16. 17. NOTE THAT SOME SYSTEMS WILL REQUIRE WORK BEYOND CONSTRUCTION SEQUENCE ZONES IN ORDER TO SUPPORT SPACES WITHIN EACH CONSTRUCTION SEQUENCE. COORDINATE THIS WORK WITH GENERAL CONTRACTOR AND OWNER PRIOR TO STARTING WORK OUTSIDE OF CONSTRUCTION SEQUENCE AREA. COORDINATE DEMOLITION/ CONSTRUCTION WORK HOURS, CONSTRUCTION SEQUENCE AND CONSTRUCTION ACCESS WITH OWNER TO MINIMIZE DISRUPTION OF NORMAL DAILY FUNCTION OF OWNER OCCUPIED AREAS. 18. REVIEW DEMOLITION DOCUMENTS WITH OWNER TO VERIFY ANY ITEMS TO BE SALVAGED AND TURNED OVER TO THE OWNER. NOISE DURING DEMOLITION TO BE KEPT TO A MINIMUM. COORDINATE WITH OWNER 72 HOURS PRIOR TO COMMENCEMENT OF PARTICULARLY NOISY WORK SUCH AS CORE-DRILLING. CONTRACTOR TO PROVIDE M.O.P. (METHOD OF PROCEDURE) PRIOR TO COMMENCEMENT OF WORK IN ANY PHASE/SUB-PHASE WHICH AFFECTS HOSPITAL OPERATION. M.O.P.'S TO BE APPROVED BY OWNER AT LEAST 72 HOURS PRIOR TO START OF WORK. DEMOLITION KEY NOTES: 1. REMOVE CROWN MOULDING 2. PARTITIONS/ITEMS TO REMAIN PROTECT FLOORING CONTRACTOR TO COORDINATE EXISTING EQUIPMENT TO BE RELOCATED WITH OWNER. 3. PROTECT CEILING GRID 4. PROTECT BATHROOM & HAND SINK 5. PROTECT FLOOR BASE TO REMAIN 6. PROTECT OUTLETS TO REMAIN 7. REMOVE EXISTING CASEWORK 8. REMOVE FLOOR & BASE 9. REMOVE CURTAIN & TRACKS 10. REMOVE DOOR, FRAME AND HARDWARE 11. REMOVE DOOR, EXISTING FRAME TO REMAIN, SAVE HARDWARE FOR RE-USE. 19. PROVIDE METAL STUD AND GYPSUM BOARD DUST/PRIVACY ENCLOSURES FOR DEMOLITION WORK TO MAINTAIN SEPARATION OF CONSTRUCTION AND IN-USE SPACES. REFER TO SHEET G002A.1B FOR ADDITIONAL INFORMATION 20. CORE-DRILL EXISTING FLOOR AND/OR ROOF AS REQUIRED FOR NEW PLUMBING OR ELECTRICAL SYSTEMS. SAWCUT FLOOR SLABS TO SLAB DEPTH ONLY, TO PREVENT DAMAGE TO UNDER SLAB UTILITIES 21. PATCH UNDER SLAB SYSTEMS AND FLOOR SLABS TO MATCH ADJACENT CONSTRUCTION AFTER THE UNDER FLOOR PLUMBING WORK IS COMPLETED AND INSPECTED. REFER TO PLUMBING DOCUMENTS 12. REMOVE WALL 13. REMOVE EXISTING SEAMLESS FLOOR AND INTEGRAL COVE BASE AT ONE INCH BEYOND THE DEEPEST REMOVED CASEWORK, USING ONE STRAIGHT CUT. 000 4' 8' 16' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/8" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 7/6/2015 5:06:04 PM AD102A.1B Checker Author ARCHITECTURAL DEMOLITION PLAN, LEVEL 02 VAIL VALLEY MEDICAL CENTER 181 WEST MEADOW DRIVE VAIL, CO TEMPORARY ICU ROOMS 218 & 219 HII-1302604 100% CONSTRUCTION DOCUMENTS 07/08/2015 MEP: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 201, Denver, CO 80202 720.407.6002 1/8" = 1'-0" 1 SECOND FLOOR DEMOLITION PLAN - PHASE 1B 07/31/15