HomeMy WebLinkAboutE001A.1B.pdfL U M I N A I R E S C H E D U L E TYPE DESCRIPTION LAMPS VOLT AMPS MANUFACTURER CATALOG NO. VOLTAGE FINISH MOUNTING RECESS W3 7" WIDE X 14.5" TALL WALL SCONCE WITH TOP AND BOTTOM LENS LED 2000 LUMENS 3500K 13 ADVENT AIW8281-BL-TL-PT49 277 BRONZE SURFACE - W4 PATIENT ROOM STEPLIGHT, AMBER LED LED 1 KENALL MSL-L-0-MW-8-ALL 277 MATTE WHITE RECESSED 3" T1 2' X 4' LED TROFFER LED 4100 LUMENS 3500K 45 MAXLITE MLFP-24-EP-45-35 277 WHITE RECESSED 2" L5 4' X 4" WIDE RECESSED LINEAR WITH DIFFUSE LENS LED 4000 LUMENS 3500K 51 FOCALPOINT FSM4L FL-1000LF 277 MATTE WHITE RECESSED 5" GENERAL NOTES: * CATALOG NUMBER REFERS TO FIRST NAME LISTED UNDER MANUFACTURER PER LUMINAIRE TYPE. REMAINING MANUFACTURERS LISTED ARE CONSIDERED EQUIVALENT PRODUCTS FOR THIS PROJECT AND SHALL MEET ALL CRITERIA LISTED INCLUDING THAT CALLED FOR BY THE SPECIFIC LUMINAIRE CATALOG NUMBER. CATALOG NUMBERS DO NOT NECESSARILY REPRESENT COMPLETE CATALOG NUMBERS. ALL ITEMS LISTED IN THE DESCRIPTION SHALL BE PROVIDED. * ALL LIGHTING REQUIRING A BALLAST SHALL BE PROVIDED WITH AN ELECTRONIC HIGH POWER FACTOR BALLAST WITH LESS THAN 10% THD. * PROVIDE QUANTITY OF BALLASTS FOR INDIVIDUAL LUMINAIRES AS REQUIRED TO ACCOMMODATE SWITCHING ARRANGEMENTS AS SHOWN ON THE DRAWINGS. * PROVIDE UNIT PRICING FOR ALL LUMINAIRES BY TYPE AND SUBMIT WITH BID FORM FOR ALL LUMINAIRES iN THIS SECTION. * PROVIDE MVOLT/MULTI-VOLTAGE COMPATIBLE BALLASTS FOR ALL LUMINAIRES WHICH CAN BE SPECIFED AS SUCH. * PROVIDE FACTORY INSTALLED BALLAST DISCONNECT SWITCH FOR FLUORESCENT LUMINAIRES PER NEC 410. * REFER TO LIGHTING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS GENERAL ABBRIVATIONS ST=SOURCE TRANSFER #=DUAL BALLAST V=VANDAL RESISTANT S=HIGH SECURITY W=WET LOCATION DL=DAMP LOCATION WG=WIRE GUARD C=CLEAN ROOM Z=HAZ MAT E=EMERGENCY BATTERY PACK VT=VAPOR TIGHT XP=EXPLOSION PROOF EXISTING PANEL "CL2A" Panel Notes: M.L.O. VOLTAGE 120 / 208 V 1. NEW LOAD ON EXISTING CIRCUIT BREAKER. 100 A BUS PHASE 3 PH 2. PROVIDE NEW CIRCUIT BREAKER IN SPACE TO MATCH EXISTING. WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKER AS SHOWN. MFR : 4. EXISTING LOAD ON NEW CIRCUIT BREAKER. EXISTING LOAD IS ESTIMATED. MTG. : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) 5. EXISTING LOAD REMOVED. 6. NEW LOAD. BREAKER BREAKER NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE R-CATH CTRL 540 540 20 / 1 1 A 2 20 / 1 0 SPARE NURSE LNG R-CATH CTRL 360 50 410 20 / 1 3 B 4 20 / 1 1080 1,080 R- PENTHOUSE R-CATH CTRL 540 540 20 / 1 5 C 6 20 / 1 0 SPARE 3RD FL ELEV. R-PCU W NURSE ST 540 540 20 / 1 7 A 8 20 / 1 1000 1,000 R-LENNEL IT CLOSET R-PCU W NURSE ST 540 540 20 / 1 9 B 10 20 / 1 1000 1,000 R-IT CABINET IN IT RM SPARE PCU WEST 0 20 / 1 11 C 12 20 / 1 1000 1,000 R-CELL BOOST/INT R-PT CLOSET/ LENEL 1,080 1080 20 / 1 13 A 14 20 / 1 720 720 R-PED/CATH/EXAM HW R-PCU N NURSE ST 540 540 20 / 1 15 B 16 20 / 1 720 720 R-PED/CATH/EXAM HW R-PCU N NURSE ST 540 540 20 / 1 17 C 18 20 / 1 180 180 R-PED/CATH/EXAM R-CATH CTRL 360 100 460 20 / 1 19 A 20 20 / 1 360 360 R-CRASH CART SPARE 0 20 / 1 21 B 22 20 / 1 1000 1,000 R- NOURISH REF R- PATIENT RM 3 720 720 20 / 1 23 C 24 20 / 1 1500 1,500 R- NOURISH COFFEE R- PATIENT RM 4 720 720 20 / 1 25 A 26 20 / 1 1000 1,000 R- NOURISH ICE R- PATIENT RM 3 & 4 360 360 20 / 1 27 B 28 20 / 1 1500 1,500 R- NOURISH MICRO R- PATIENT RM 10 720 720 20 / 1 29 C 30 20 / 1 1080 1,080 R- PATIENT RM 218 1 R- PATIENT RM 11 720 720 20 / 1 31 A 32 20 / 1 1080 1,080 R- PATIENT RM 219 1 R- PATIENT RM 10 & 11 720 720 20 / 1 33 B 34 20 / 1 0 SPARE R- CATH WEST 0 20 / 1 35 C 36 20 / 1 0 SPARE R- CATH WEST 0 20 / 1 37 A 38 20 / 1 0 SPARE SPARE 0 20 / 1 39 B 40 20 / 1 0 SPARE SPARE 0 20 / 1 41 C 42 20 / 1 0 SPARE PHASE LOADING SUMMARY PANEL LOADING SUMMARY LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL RECEPTACLES 6,120.0 4,320.0 3,780.0 CONNECTED PF= MOTORS 0.0 0.0 0.0 LIGHTING 0.0 KVA x 125% = 0.0 KVA x 95% = 0.0 KW 100% OTHER 0.0 0.0 0.0 RECEPTACLES GENERAL 2,100.0 3,550.0 2,500.0 FIRST 10 KVA 10.0 KVA x 100% = 10.0 KVA x 100% = 10.0 KW CONNECTED TOTAL (VA) 8,220.0 7,870.0 6,280.0 REMAINDER 4.2 KVA x 50% = 2.1 KVA x 100% = 2.1 KW AMPACITY = MOTORS 62.1 NEC CALCULATED LARGEST 0.0 KVA x 125% = 0.0 KVA x 90% = 0.0 KW PHASE AMPACITY 68.4 65.5 52.2 REMAINDER 0.0 KVA x 100% = 0.0 KVA x 90% = 0.0 KW NEC DEMAND OTHER 0.0 KVA x 125% = 0.0 KVA x 100% = 0.0 KW AMPACITY = #VALUE! GENERAL 8.2 KVA x 100% = 8.2 KVA x 100% = 8.2 KW 56.2 PHASE BALANCE A-B B-C C-A 4% 25% 31% TOTAL 22.4 KVA 20.3 KVA 20.3 KW GENERAL NOTES: BREAKER ACCESSORIES ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. * = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. ** = SHUNT TRIP EXISTING PANEL "NL2A" Panel Notes: M.L.O. VOLTAGE 120 / 208 V 1. NEW LOAD ON EXISTING CIRCUIT BREAKER. 100 A BUS PHASE 3 PH 2. PROVIDE NEW CIRCUIT BREAKER IN SPACE TO MATCH EXISTING. WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKER AS SHOWN. MFR : 4. EXISTING LOAD ON NEW CIRCUIT BREAKER. EXISTING LOAD IS ESTIMATED. MTG. : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) 5. EXISTING LOAD REMOVED. 6. NEW LOAD. BREAKER BREAKER NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE R-NURSE DIR.OFFICE 1,080 1080 20 / 1 1 A 2 20 / 1 500 500 R-NOISE GEN PCU W R-MECH 1,080 1080 20 / 1 3 B 4 20 / 1 360 360 R-LINEN/JANITOR R-MED. CONFERENCE 540 540 20 / 1 5 C 6 20 / 1 500 500 DRINKING FOUNTAIN R-NURSE DIR.OFFICE 1,080 1080 20 / 1 7 A 8 20 / 1 1176 1,176 EX. FAN #1 R-DR. O.C. LOBBY 1,080 1080 20 / 1 9 B 10 20 / 1 1176 1,176 N.E. EX. FAN R-CATH HALLS, LKR 1,260 1260 20 / 1 11 C 12 20 / 1 400 400 R-200 A-B/LIGHTING R-SOIL/MED. WK. DICT 1,080 1080 20 / 1 13 A 14 20 / 1 1440 1,440 R-HEADWAll 200 A-D R- PED/CATH EXAM 360 360 20 / 1 15 B 16 20 / 1 1440 1,440 R-200 C-D R-CATH STORAGE 1,080 1080 20 / 1 17 C 18 20 / 1 1440 1,440 R- PED/CATH EXAM HW L-BATH 200 A-D/HEAD LT D 400 400 20 / 1 19 A 20 20 / 1 560 540 20 R- SOIL, LINEN, NOUR R-1ST FL. ROOF 360 360 20 / 1 21 B 22 20 / 1 900 900 CATH LAB, CTRL R- HALLS, HSK, TUB 10 720 730 20 / 1 23 C 24 20 / 1 900 900 MED SUPPLIES R-2ND FL.ELEV. LBY 360 360 20 / 1 25 A 26 20 / 1 560 540 20 CATH LAB CATV 1,000 1000 20 / 1 27 B 28 20 / 1 0 SPARE R-2ND FL.ELEV. LBY 360 360 20 / 1 29 C 30 20 / 1 1080 1,080 R-OFFICE 240 R-PT RM 3 & 4 HEADWALL 1,440 1440 20 / 1 31 A 32 20 / 1 1440 1,440 R- PATIENT RM 218,219 1 R-PATIENT RM 3 & 4 720 720 20 / 1 33 B 34 20 / 1 0 SPARE R-PT RM 10 & 11 HEADWALL 1,440 1440 20 / 1 35 C 36 20 / 1 0 SPARE R-PATIENT RM 10 & 11 1,440 1440 20 / 1 37 A 38 20 / 1 0 SPARE OFFICE OT/PT 900 900 20 / 1 39 B 40 20 / 1 0 SPARE R-TEMP STORAGE 1,080 1080 20 / 1 41 C 42 20 / 1 0 SPARE PHASE LOADING SUMMARY PANEL LOADING SUMMARY LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND LIGHTING 440.0 0.0 410.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL RECEPTACLES 10,440.0 7,200.0 9,900.0 CONNECTED PF= MOTORS 1,176.0 1,176.0 500.0 LIGHTING 0.9 KVA x 125% = 1.1 KVA x 95% = 1.0 KW 99% OTHER 0.0 0.0 0.0 RECEPTACLES GENERAL 500.0 1,000.0 0.0 FIRST 10 KVA 10.0 KVA x 100% = 10.0 KVA x 100% = 10.0 KW CONNECTED TOTAL (VA) 12,556.0 9,376.0 10,810.0 REMAINDER 17.5 KVA x 50% = 8.8 KVA x 100% = 8.8 KW AMPACITY = MOTORS 90.9 NEC CALCULATED LARGEST 0.0 KVA x 125% = 0.0 KVA x 90% = 0.0 KW PHASE AMPACITY 106.0 80.4 91.8 REMAINDER 2.9 KVA x 100% = 2.9 KVA x 90% = 2.6 KW NEC DEMAND OTHER 0.0 KVA x 125% = 0.0 KVA x 100% = 0.0 KW AMPACITY = #VALUE! GENERAL 1.5 KVA x 100% = 1.5 KVA x 100% = 1.5 KW 67.1 PHASE BALANCE A-B B-C C-A 34% 15% 16% TOTAL 32.7 KVA 24.2 KVA 23.8 KW GENERAL NOTES: BREAKER ACCESSORIES ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. * = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. ** = SHUNT TRIP "CL2A" LOAD SUMMARY LOAD ADDED QTY VA RECEPTACLES 12 2160 T1 4 180 W4 2 2 LOAD REMOVED RECEPTACLES 8 400 EXISTING LED 2X4 1 50 EXISTING 2X4 BASKET 4 256 EXISTING STEP LIGHT 4 80 EXISTING WALL MOUNT 4 256 NET LOAD REMOVED 860 VA "NL2A" LOAD SUMMARY LOAD ADDED QTY VA RECEPTACLES 8 1440 W3 4 52 L5 2 102 LOAD REMOVED RECEPTACLES 13 2340 EXISTING LED 2X4 1 50 EXISTING SCONCE 2 70 NET LOAD REMOVED 866 VA 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by consultants/construction managers owner's project number project number Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 sheet number sheet title item date date issued for seal/signature MEP: CATOR RUMA & ASSOCIATES, CO. 896 TABOR STREET LAKEWOOD, CO 80401-4700 303.232.6200 INTERIORS: GALLUN-SNOW 1920 MARKET STREET, SUITE 201 DENVER, CO 80202 303.433.9600 TEMPORARY ICU ROOMS 218 & 219 100% CONSTRUCTION DOCUMENTS 07/08/2015 E001A.1B ELECTRICAL LEGENDS AND SCHEDULES NCW NCW 07/31/15