Loading...
HomeMy WebLinkAboutG112A.1B.pdfUP UP UPUP EOCC2 EOCC2 EOCC2EOCC2 EOCC2 EOCC2 EOCC2 EOCC2 EOCC2 EOCC2 EOCC2 EOCC2 E2FE2F E2FE2F E2F E2F E2F E2FE2F E2F E2F E2FE2F E2F E2F E2F E2F E2F E2F E2FE2F E2FE2F E2FE2F E2FE2F 1F 1F 1F1F 1F 1F 1F1F 1F 1F 1F 1F E2FE2F E2FE2F 1FS 1FS E2F E2F E2F E2F 1FS 1FS 1F 1F 1F 1F 1FS1FS 1FS1FS 1FS1FSE1FE1F E1F E1F SS SS SS S S SS 1F1F 1F1F E2F E2F E2F E2FE2F 1FS1FS 1FS 1FS 1F 1F 1FS1FS 1F 1F EOCC2 EOCC2 1FS 1FS 1F 1F 2F 2F E1FS E1FS E1F E1F E2F E2F S S 1 2 3 4 5 6 7 8 F E D C B G H J K FF 2e1978 Be1978 3e19784e19785e1978 6e1978 7E1978 9E1978 12E197813E1978 14E1978 15E197817E1978 18E197819E1978 21E1978 1e2001 De2001 Fe2001 He2001 Je2001 2e2001 3e2001 4e2001 5e2001 6e2001 7e2001 8e2001 Ee2001 Ge2001 De1978 Je1978 Ge1978 Ce1978 H.3 1E 1.3E 2E 2.5E 3E 3.5E 4E 5E 6E 7E 8E A.E A.5E B.E B.3E B.8E C.E D.E E.E F.E F.8E G.E H.E J.E K.E L.E M.E N.E C.2E J.2 Aa A 4.5 Aa.6 A.4 G.4 G.7 2.4 2.7 1.1 H.1 1.6 0.7 Aa.1 1.5 F.4 e 184 FT OCCUPANT LOAD TABULATION FOR EACH S.C. 2.1 EXISTING SMOKE COMPARTMENT 102 FT 132 FT 139 ft NON PATIENT CARE SUITE 1215 SF 37 FT HEALTH CARE O.L. FACTOR: SLEEPING AREA 1:20 SF GROSS (UNO) NON-SLEEPING AREA 1:240 SF GROSS (UNO) ASSEMBLY USE O.L. FACTOR 1:15 SF NET(UNO) LEVEL 2 GROSS FLOOR AREA OF S.C.# 2.1 = 18,519 SQ. FT. HEALTH CARE O.L.= 18,305/120=152 TOTAL ASSEMBLY USE O.L.= 214/15 =15 TOTAL S.C. #2.1 O.L. 167 STAIR: C STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 44" CAPACITY(44"/.3): = 146 DOOR EXIT CAPACITY CLEAR WIDTH: = 33" CAPACITY (36"/.2): =165 ACTUAL OCCUPANT LOAD: = 74 A STAIR: B STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 44" CAPACITY (44"/.3) : =146 DOOR EXIT CAPACITY CLEAR WIDTH: = 33" CAPACITY (33"/0.2): =165 ACTUAL OCCUPANT LOAD: = 74 STAIR: A STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 44" CAPACITY (44"/.3) : = 146 DOOR EXIT CAPACITY CLEAR WIDTH: = 33" CAPACITY (33/.02): = 165 ACTUAL OCCUPANT LOAD: = 66 S SG SG SG S S 10 OL EXISTING BUSINESS OCCUPANCY S STP FEC STP FEC STP FEC 49 FT 10 OL OCCUPANT LOAD TABULATION FOR EACH S.C. 2.2 HEALTH CARE O.L. FACTOR: SLEEPING AREA 1:20 SF GROSS (UNO) NON-SLEEPING AREA 1:240 SF GROSS (UNO) LEVEL 2 GROSS FLOOR AREA OF S.C.# 2.2 = 13,396 SQ. FT. HEALTH CARE O.L.= 13,396/120=112 TOTAL S.C. #2.2 O.L. 112 + 20 FROM S.C 2.1=132 STAIR: EXISTING STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 44" CAPACITY(44"/.03): = 146 DOOR EXIT CAPACITY CLEAR WIDTH: = 36" CAPACITY (33/.02): = 165 ACTUAL OCCUPANT LOAD: = 66 FEC STP FEC FEC S1 82 SF S1 S1 94 SF S1 68 SF G1 AREA OF WORK FIRE EXTINGUISHER AND WALL MOUNTING BRACKET 0 HR FRR SMOKE WALL (PARTITION) 1 HR FRR SMOKE BARRIER 20 MIN. PROTECTED DOORS 1 HR FIRE BARRIER WITH 45 MIN. PROTECTED DOORS. 2 HR FFR FIRE BARRIER MIN. 1 1/2 HR PROTECTED DOORS WALL RATINGS NEW CONSTRUCTION SG EXISTING 0 HR SMOKE CONTROL PARTITION EXISTING 1 HR FRR SMOKE BARRIER WITH MIN 20 MINUTE PROTECTED DOORS EXISTING 1 - HR FIRE FRR FIRE BARRIER EXISTING 2 HR FIRE BARRIER MIN 1 1/2 PROTECETED DOORS EXISTING SMOKE GUARD AT ELEVATOR OPENING WALL RATINGS EXISTING CONSTRUCTION (HALF TONE) NEW CORRIDOR OR SUITE SEPARATION WALLS THAT LIMIT TRANSFER OF SMOKE (SMOKE PARTITION PER IBC). NEW CORRIDOR SUITE DOORS ARE SELF LATCHING AND PROVIDED WITH POSITIVE LATCHING HARDWARE (UNO). EXISTING CORRIDOR WALLS THAT LIMIT TRANSFER OF SMOKE (SMOKE PARTITION PER IBC). DOORS ARE POSITIVE LATCHING (UNO). CONSTRUCTION HAS OCCURED UNDER DIFFERENT AND WHERE EXISTING DOORS ARE FIRE PROTECTED/ RATED, THEY ARE CONSIDERED AS DOORS THAT RESIST PASSAGE OF SMOKE WITH POSITIVE LATCHING HARDWARE AND WITHOUT LOUVERS. LIFE SAFETY LEGEND S STORAGE ROOM > 100 S.F. MED GAS ROOM, SOILED LINEN ROOM, 1-HR FRR 45 MIN PROTECTED DOORS S1 STORAGE ROOM 50-100 S.F., 0-HR SMOKE WALL (PARTITION). (SELF CLOSING, POSITIVE LATCH DOOR) SMOKE COMPARTMENT 20 MINUTE DOOR U.N.O. REQUIRED CORRIDOR- 0 HR FRR SMOKE WALL (PARTITION) EA. SIDE POSITIVE LATCH DOOR SUITE - 0 HR FRR SMOKE WALL (PARTITION) FE FIRE EXTINGUISHER AND CABINET FEC FIRE VALVE CABINET FVC STAND PIPE STP EGRESS COMPONENT CAPACITY DIRECTION AND MAXIMUM TRAVEL DISTANCE FROM FURTHEST POINT x ACCUMULATED OCCUPANCY LOAD TAG EXIT XXX USE GROUP OCCUPANCIES ASSEMBLY USE A OCCUPANCY IS CONSIDERED I-2 UNLESS OTHERWISE INDICATED PER LEGEND BELOW BUSINESS OCCUPANCY (NON HEALTHCARE) BUSINESS BOUNDARY OF THE RENOVATION AREA EXISTING OCCUPANCY SEPARATION FOR CLARITY, THIS SHEET SHOULD BE PRINTED IN COLOR OR EXISTING FINAL COMMENTS PATIENT SHWR WC LAV TUB PLUMBING FIXTURE COUNT LEVEL 2, WEST WING 26 24 24 1 1 20 25 EXISTING PATIENT ROOMS =26 NEW PATIENT ROOMS =24 22 STAFF SHWR WC LAV 2 2 2 1 2 0 1 SCRUB SINK 1 PED. SINK PUBLIC WC LAV 1 1 11 DRINKING FOUNTAINS 1 PUBLIC WC LAV 1 1 1 1 JAN CLOSET MOP SINK HAND SINK 2 1 1 2 000 8' 16" 32" SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/16" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 7/6/2015 4:54:50 PM G112A.1B Checker Author LIFE SAFETY PLAN, LEVEL 02 VAIL VALLEY MEDICAL CENTER 181 WEST MEADOW DRIVE VAIL, CO TEMPORARY ICU ROOMS 218 & 219 HII-1302604 100% CONSTRUCTION DOCUMENTS 07/08/2015 MEP: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 201, Denver, CO 80202 720.407.6002 1/16" = 1'-0" 1 TEMPORARY ICU ROOMS 218 & 219 - LEVEL 2 LIFE SAFETY PLAN 07/31/15