Loading...
HomeMy WebLinkAboutFS 2.0.pdfP 12 P 6 P 16 P 18 P 23 P 28 P 35 P 35 P 41 P 38 P 6 P 24 P127 P131 P128 P126 CW 1/2" FS CW 12"x12" 1/2" CW 1/2" 2 24" WALL - 12" FLOOR 4 WALL 2 50" WALL 2 GLASS FILLER STATION BEER TOWER & WALK-IN BEER COOLER EVAP. COIL SODA/ICE DISPENSER - VFY. REQUIREMENTS w/VENDOR COFFEE/TEA BREWER - VFY. REQUIREMENTS w/VENDOR 1 3-COMPARTMENT SINK FAUCET 14" WALL CW/HW 1/2" EA. P16 P91 P76 P78 P75 P67 P74 4 - FLOOR FSHG 12"x12" 50,000 68,000 110,000 215,000 GAS GAS GAS 3/4" 3/4" 3/4" FSHG GAS 12"x12" 3/4" 30" 24" 30" 5 WALL WALL 5 WALL 5 - 24" FLOOR WALL 4 5 P41 P55 P56 P54 P38 P23 " " 215,000 100,000 GAS 3/4" CW/HW FSHG HW 1/2" EA. 12"x12" 1/2" GAS 3/4" 5 24" WALL 18" - 66" 1 WALL FLOOR 4 WALL 2 24" WALL 5 CW 1/2" FSHG 12"x12" FSHG 12"x12" 2 72" WALL - FLOOR 4 - FLOOR 4 DROP-IN HOT WELLS DRAIN TO FLOOR SINK CHARBROILER 6-BURNER RANGE w/STANDARD OVEN BASE COUNTERTOP GRIDDLE DROP-IN HOT WELL & COLD FOOD PAN DRAIN TO FLOOR SINK FRYER DOUBLE CONVECTION OVEN - MANIFOLDED FOR SINGLE POINT CONNECTION PRE-RINSE FAUCET SCRAPPING SINK & DISH MACHINE DRAIN TO FLOOR SINK DISH WASHER - VFY. REQUIREMENTS w/OWNER 6-BURNER RANGE w/STANDARD OVEN BASE WATER FILTER - P.C. INTERPLUMB CW THRU FILTER TO ICE CUBER ICE CUBER & BIN DRAIN TO FLOOR SINK 3-COMPARTMENT SINK DRAINS TO FLOOR SINK Type Conn. " P6 No. BTU DW CW/HW 1 1/2" EA. 1/2" EA. Size Item 20" 24" WALL 3 WALL 1 AFF LOC. RIP HAND SINK FAUCET DRAINS TO DIRECT WASTE (2) RIP'S HAND SINK FAUCET (2) RIP'S Remarks P L U M B I N G S C H E D U L E P12 FS 12"x12" - FLOOR 4 WALK-IN COOLER EVAP. COIL CONDENSATE DRAIN LINE DRAINS TO FLOOR SINK 1 PREP TABLE FAUCET 14" WALL CW/HW 1/2" EA. P18 " FSHG 12"x12" - FLOOR 4 PREP TABLE SINK DRAINS TO FLOOR SINK 1 WORK TABLE FAUCET 14" WALL CW/HW 1/2" EA. P28 " FSHG 12"x12" - FLOOR 4 WORK TABLE SINK & WALK-IN COOLER EVAP. COILCONDENSATE DRAIN LINE DRAIN TO FLOOR SINK 1 3-COMPARTMENT SINK FAUCET (2) RIP'S 14" WALL CW/HW 1/2" EA. P35 " FSHG 12"x12" - FLOOR 4 3-COMPARTMENT SINKS DRAIN TO FLOOR SINK " P61 DW CW/HW 1 1/2" 1/2" EA. 20" 24" WALL 3 WALL 1 HAND SINK FAUCET DRAINS TO DIRECT WASTE HAND SINK FAUCET " P99 DW CW/HW 1 1/2" 1/2" EA. 20" 24" WALL 3 WALL 1 HAND SINK FAUCET DRAINS TO DIRECT WASTE HAND SINK FAUCET P109 CW/HW 1/2" EA. 1 BLENDER STATION FAUCET P111 CW/HW 1/2" EA. 1 HAND SINK FAUCET P113 2 CW 1/2" SODA GUN/CARBONATOR - VFY. REQUIREMENTS w/VENDOR " 4 - FLOOR FSHG 12"x12" GLASS HANDLING CABINET & DRAIN BOARDS DRAIN TO FLOOR SINK P115 CW/HW 1/2" EA. 1 GLASS HANDLING CABINET FAUCET P107 HW 1/2" 2 GLASS WASHER - VFY. REQUIREMENTS w/OWNER CONDENSATE DRAIN LINE DRAIN TO FLOOR SINK P137 " CW 1/2" FSHG 12"x12" 2 72" WALL - FLOOR 4 WATER FILTER - P.C. INTERPLUMB CW THRU FILTER TO ICE CUBER ICE CUBER & BIN DRAIN TO FLOOR SINK 4 - FLOOR FSHG 12"x12" HAND SINK, BLENDER STATION, DRAINBOARD, ICE BIN & GLASS WASHER DRAIN TO FLOOR SINK " " FSHG 12"x12" - FLOOR 4 SODA/ICE DISPENSER & WATER FILLER DRAIN TO FLOOR SINK FROM WALL P105 BAR DIE P92 1 CW HOT WELL FILL FAUCET STUB UP 4" 1/2" FLOOR P73 1 CW HOT WELL FILL FAUCET STUB UP 4" 1/2" FLOOR P24 CW 1/2" 2 78" WALL SODA SYSTEM - VFY. REQUIREMENTS w/VENDOR 12" WALL 12" WALL 12" WALL 8" WALL 2 2 2 2 2 2 2 FD P 54 P 55 P 56 P 61 P 74 P 75 P 76 P 67 P 78 P 91 P 99 P 128 P 127 P 131 P 137 VERIFY EXACT LOCATION OF WALK-IN COOLER COMPRESSOR w/MECHANICAL/ARCHITECTURAL DRAWINGS P.C. TO PATCH & SEAL WALL AROUND BEER TOWER DRAIN LINE. P 115 P 73 P 92 P 126 P 107 P 113 P 109 P 111 P 113 P 115 2 8" 1" AIR GAP INSULATED WALK-IN WALL COPPER DRAIN LINE COPPER UNION ALL DRAIN LINES REQUIRE A MINIMUM FALL OF 1/4" PER FOOT AIR FLOW COIL INSULATED SUCTION LINE & LIQUID LINE REFRIGERATION CONTRACTOR TO SEAL PENETRATION EVAPORATOR DRAIN DETAIL 15" FLOOR FS2 Plumbing Rough-in Plan & Schedule PLUMBING ROUGH-IN PLAN (MAIN LEVEL GRILL/CATERING KITCHEN) SCALE: 1/4" = 1'-0" PLUMBING NOTES: 1. ALL ROUGH-INS SHOWN RELATE TO FOOD SERVICE EQUIPMENT ONLY. SEE ARCHITECTURAL/ENGINEERING PLANS FOR ADDITIONAL PLUMBING REQUIREMENTS. 2. FINAL CONNECTIONS TO ALL EQUIPMENT BY PLUMBING CONTRACTOR, INCLUDING REQUIRED MATERIALS, SUCH AS STOPS, VALVES, FILTERS, TRAPS, CHECK VALVES, PRESSURE REDUCING VALVES, PIPING, ESCUTCHEON PLATES, TUBING, ETC.. 3. WATER QUALITY REQUIREMENT. THE RECOMMENDED MINIMUM WATER QUALITY STANDARDS WHETHER UN- TREATED OR PRE-TREATED, BASED UPON 10 HOURS OF USE PER DAY AND A DAILY BLOW DOWN, ARE AS FOLLOWS: - TOTAL DISSOLVED SOLIDS LESS THEN 300 P.P.M. - TOTAL ALKALINITY LESS THEN 85 P.P.M. - SILICA LESS THEN 13 P.P.M. - pH FACTOR GREATER THEN 7.5 P.P.M. 4. VERIFY ALL PLUMBING ROUGH-INS & LOCATIONS WITH OWNER, VENDOR, OR G.C. ON EXISTING EQUIPMENT OR OTHER EQUIPMENT NOT PROVIDED BY W.WEST. 5. PLUMBING CONTRACTOR TO FURNISH AND INSTALL THE FOLLOWING AS PER CODE a. ALL WATER, WASTE, GAS, AND STEAM SERVICE TO POINT OF ROUGH-IN AS SHOWN ON PLAN. ROUGH-IN OUTLETS TO STUB 4" OUT OF WALL AT HEIGHT INDICATED FROM FINISHED FLOOR OR CURB. ALL FLOOR OPENINGS ARE TO BE SEALED WATERTIGHT. b. PRESSURE REDUCING AND/OR REGULATING VALVES FOR DISHWASHERS, BOOSTER HEATERS, AND AS OTHERWISE NOTED, KITCHEN AREAS. c. ALL FLOOR SINKS, COMPLETE WITH TOP GRATES INDICATED AND REMOVABLE SEDIMENT BUCKETS SET FLUSH WITH FINISHED FLOOR, UNLESS NOTED OR AS PER LOCAL CODE. d. ALL WASTE LINES, DIRECT OR INDIRECT, EXCEPT AS NOTED, SHALL BE PITCHED DOWNWARD, ALL WASTE LINES SHALL HAVE ADEQUATE, CLEAN-OUT PROVISIONS. e. INDIRECT WASTE LINES FOR WALK-IN REFRIGERATOR/ FREEZER PITCHED 1/4" TO 1'-0" (MINIMUM) AND WITH A "P" TRAP AT MINIMUM 2" ABOVE FLOOR SINK. f. HEATER TAPE WITH 35 WATTS PER LINEAL FOOT OF DRAIN LINE AND INSULATION OF ALL DRAIN LINES INSIDE WALK-IN FREEZER COMPARTMENTS. g. INSTALL FIRE CONTROL GAS SHUT-OFF VALVES AS PER SUPPLIED BY FIRE PROTECTION SYSTEM CONTRACTOR. (IF GAS COOKING EQUIPMENT IS USED.) h. VACUUM BREAKERS AS REQUIRED. i. INSULATION OF ALL STEAM, HOT WATER AND CON- DENSATE LINES IN KITCHEN. ALL SUCH LINES ARE TO BE COLOR CODED ACCORDING TO LOCAL CODES. j. CLEAN-OUT VALVES FOR STEAM CONDENSATE AND AIR LINES. k. ALL PIPING TO AND FROM EQUIPMENT SHALL BE KEPT AT A MINIMUM OF SIX INCHES (6") CLEAR ABOVE FINISHED FLOOR TO ALLOW CLEANING, OR PREVAILING LOCAL CODES. l. IN-LINE WATER FILTERS ARE RECOMMENDED FOR THE FOLLOWING EQUIPMENT" (WATER FILTERS TO BE BY P.C UNLESS OTHER WISE NOTED.) · WATER HEATERS · BOOSTER HEATERS · SINK HEATERS · DISHWASHERS · GLASSWASHERS · SODA SYSTEMS · STEAM EQUIPMENT · ICE MAKING MACHINES · WATER STATIONS 6. PLUMBING DIVISION TO INTERCONNECT DISHMACHINE WITH BOOSTER HEATER AND WATER TYPE VENTILATORS WITH CONTROL PANELS AS PER MANUFACTURER'S INSTRUCTIONS, WHEN APPLICABLE AND NOTED. 7. ALL VENT PIPES ARE TO BE CONCEALED IN WALLS OR COLUMN CHASES. 8. ALL LINES ROUTED THROUGH EQUIPMENT SHALL NOT INTERFERE WITH INTENDED USE OF, OR SERVICING OF EQUIPMENT. 9. INTERCONNECTION BETWEEN STEAM EQUIPMENT AND STEAM GENERATOR. 10. GREASE TRAP TO BE SPECIFIED AND LOCATED BY MECHANICAL ENGINEER AND PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR OR PLUMBING CONTRACTOR. 11. A GAS PRESSURE REGULATOR FOR EACH PIECE OF GAS FIRED EQUIPMENT SHALL BE PROVIDED AND INSTALLED BY P.C. UNLESS OTHERWISE NOTED. IN ADDITION A HIGH PRESSURE GAS REGULATOR (VENTED) SHALL BE PROVIDED AND INSTALLED BY P.C. WHEN NECESSARY. 12. FLEXIBLE GAS CONNECTIONS WITH OR WITHOUT QUICK DISCONNECT FEATURE SHALL BE PROVIDED WITH SHUT-OFF VALVE BY K.E.C.. THIS VALVE SHALL HAVE PERMANENT HANDLE, AND NOT BE LESS THEN THE NOMINAL SIZE OF THE CONNECTOR AND BE INSTALLED AT THE GAS PIPING OUTLET IMMEDIATELY AHEAD OF THE FLEXIBLE GAS CONNECTION. INSTALLED BY P.C.. 13. PLUMBER SHALL PROVIDE ALL DRAINS FROM FIXTURES. INCLUDING WALK-IN BOX EVAPORATORS. 14. IF REQUIRED BY THE BUILDING DEPARTMENT, THE P.C., UNDER HIS PERMIT APPLICATION, SHALL PROVIDE DRAWINGS OR DIAGRAMS OF PIPING LAYOUT, SEWER PIPE SIZES, VENTING CONNECTIONS, ETC. 15. PLUMBER SHALL DETERMINE AND BE RESPONSIBLE FOR THE TOTAL PROJECT REQUIREMENTS AND VERIFY SIZE OF SERVICE REQUIRED FOR GAS OR WATER. DIRECT WASTE FLOOR SINK 3/4 GRATE FUNNEL FLOOR DRAIN INDIRECT WASTE ROUGH-IN POINT ABOVE FINISHED FLOOR FROM ABOVE STEAM RETURN STEAM SUPPLY FLOOR DRAIN COLD WATER HOT WATER GAS G FA AFF RIP IW SR SS FD FS FFD DW CW HW SYMBOLS & ABBREVIATIONS EQUIPMENT CONTRACTOR MECHANICAL CONTRACTOR 2) CONNECT WATER SUPPLY TO WATER CONNECTION 1) CONNECT WATER SUPPLY TO FAUCETS 3) DIRECT WASTE CONNECTION TO UNIT 5) QUICK DISCONNECT FURNISHED BY KITCHEN 6) QUICK DISCONNECT FURNISHED BY 4) INDIRECT WASTE CONNECTION TO UNIT 8) DIRECT GAS CONNECTION 7) MANIFOLD GAS CONNECTION CONNECTION TYPES FLOOR SINK/HALF GRATE FSHG Scale:As Noted Sheet Number: Drawn By GENERAL NOTE These plans are the property of W.West and use of these plans without the written consent of W.West is prohibited. No Responsibility is assumed by W.West for deviations from these drawings. Sheet Name: Food Service Design/Planning Designer/Project Manager 9355 Northfield Blvd. Denver, CO 80238 Phone: 303.289.9378 Fax: 303.289.9505 Revisions: 1 2 3 4 5 Project Number: Tim Trujillo Vail Golf Clubhouse Vail, Colorado T15007 J.V. J.V. 07-16-15 Permit Set Equipment & Furnishings Co. Checked By Date: 08-18-15 Permit Update Revision #2 PLUMBING ROUGH-IN PLAN (LOWER LEVEL SUPPORT KITCHEN) SCALE: 1/4" = 1'-0" GENERAL G.P.H. LOADS EQUIPMENT TYPE G.P.H. HIGH G.P.H. LOW VEGETABLE SINK 25 15 TRIPLE POT SINK 60 45 PRE-RINSE 45 45 BAR 4-COMP SINK 25 25 HOT WATER FILLER 15 15 COFFEE URN 5 5 MOP SINK 15 15 HAND SINK 5 5 02/03/16