Loading...
HomeMy WebLinkAboutFS 3.0.pdfFD J J J J S J J J J J S J J J J J J V S J J V J J J J E 13 E 63 E 64 66 E 67 68 E 71 70 73 E 77 79 83 E 84 E 85 E 87 65 E 88 E 88 E 91A 92 E 93 E 96 102 102 E 91B E 103 E 103 E 118 E 119 E 121 E 126 E 128 E 132 E 131 E 137 VERIFY EXACT LOCATION OF WALK-IN COOLER COMPRESSOR w/MECHANICAL/ARCHITECTURAL DRAWINGS E.C. TO INTERWIRE FIRE PROTECTION SYSTEM TO SHUNT TRIP BREAKERS IN MAIN PANEL BOX & FIRE CONTROL CENTER, (IF REQUIRED BY CODE). E 53 E 54 E 115.1 E 107 E 113 E 109 2 No. Item Volts E L E C T R I C A L S C H E D U L E 0 Amp HP KW RIP LOC. AFF CONN. TYPE REMARKS SPO E4 120-208 REACH-IN FREEZER - NEMA 14-20P 12.6 1 1.0 48" 6,8 WALL DR E18 120 CONVENIENCE OUTLET (2) RIP'S 8.0 1 50" 8 WALL JB E23 120 ICE CUBER 13.8 1 72" 1 WALL DR E37 120 HEATED CABINET - NEMA 5-20P - (2) RIP'S 16.0 1 1.9 72" 6 WALL DR E41 120 DOUBLE CONVECTION OVEN 8.0 1 0.50 18" 6 WALL JB E54 120 DISH WASHER - VFY. REQUIREMENTS w/OWNER 16.0 1 66" 1 WALL DR E63 120 CONVENIENCE OUTLET 8.0 1 50" 8 WALL DR E64 120 REACH-IN REFRIGERATOR - NEMA 5-15P 6.5 1 0.33 80" 6 WALL SPO 66 208 CONVEYOR TOASTER - FUTURE EQUIPMENT - E.C. TO EXTEND, INSTALL & MAKE 10.7 1 2.23 -6,8 FROM JB E67 120/208 CHEF COUNTER - E.C. TO EXTEND, INSTALL & MAKEVFY. 1 VFY. VFY. 30" 1 WALL DR 68 120 MICROWAVE OVEN - E.C. TO EXTEND, INSTALL & MAKE FINAL16.8 1 1.2 -6,8 FROM JB 70 120/208 HEAT LAMP - E.C. TO EXTEND & MAKE FINAL CONNECTION1 2.44 -1,5 JB E71 120/208 TWO TIER PASS SHELF - E.C. TO EXTEND, INSTALL & MAKE FINAL CONNECTION TO ITEMS: 68 & 70 VFY. 1 VFY. 54" 1 WALL JB 73 208 DROP-IN HOT WELL - E.C. TO EXTEND & MAKE11.9 1 2.48 -1 DR E77 120 EQUIPMENT STAND - NEMA 5-15P 5.7 1 0.20 18" 6 WALL DR 79 120 REACH-IN U/C FREEZER - NEMA 5-15P - E.C. TO EXTEND, INSTALL & 5.8 1 0.33 -6,8 DR 83 120 6.3 1 0.20 -6,8 DR E84 120 FRYER DUMP STATION - NEMA 5-15P 6.3 1 0.75 18" 6 WALL DR E88 120 HEATED CABINET - NEMA 5-20P - (2) RIP'S 16.0 1 1.9 72" 6 WALL JB E91A 120/208 EXPO TABLE - E.C. TO EXTEND & MAKE FINAL CONNECTION TO (3) ITEM: 92 VFY. 3 VFY. 30" 1 WALL JB 92 208 DROP-IN HOT WELL - E.C. TO EXTEND & MAKE FINAL CONNECTION FROM ITEM: 91A 3 -1 FROM DR E93 120 CARVING STATION - NEMA 5-15P 4.2 1 0.5 30" 6 WALL DR E96 120 CONVENIENCE OUTLET 8.0 1 50" 8 WALL JB 102 120 (2) HEAT LAMP - E.C. TO EXTEND & MAKE FINAL CONNECTION FROM ITEM: 91B 1 2.44 -1,5 E91B DR E3B 120 CONVENIENCE OUTLET 8.0 1 8 WALL DR E3A 120 OFFICE COMPUTER - VFY. REQUIREMENTS w/OWNER 1 18" 6 WALL DATA " DATA PORT - VFY. REQUIREMENTS w/OWNER 8 WALL 24" 15.0 JB E12 120 WALK-IN COOLER EVAP. COIL - VFY. REQUIREMENTS w/SHOP DRAWINGS 1.8 1 FA 1 CLG JB E8 120 15.0 1 FA 1,5 CLG & OTHER DISCONNECTS AS NEEDED. WALK-IN COOLER - E.C. TO INTERWIRE SWITCH, LIGHTS, PRESSURE RELIEF VALVE, CKT. JB E13 208-230 REFRIGERATION RACK CONDENSING UNIT - VFY. REQUIREMENTS w/SHOP DRAWINGS 3 STUB 1 ROOF JB E33 120 WALK-IN COOLER EVAP. COIL - VFY. REQUIREMENTS w/SHOP DRAWINGS 2.32 1 FA 1 CLG JB E32 120 15.0 1 FA 1,5 CLG & OTHER DISCONNECTS AS NEEDED. WALK-IN COOLER - E.C. TO INTERWIRE SWITCH, LIGHTS, PRESSURE RELIEF VALVE, -E34 -DELETED - --- EA. EA. EA. EA. 36" JB E43A 120 EXHAUST HOOD - E.C. INTERWIRE LIGHTS & FANS TO SWITCH (MOUNT SWITCH TO HOOD FACE) 15.0 1 FA 1,5 CLG JB E43B 120 FIRE SUPPRESSION SYSTEM 1 FA 1 CLG 15.0 CKT. JB E53 120 CONDENSATE HOOD - E.C. INTERWIRE SWITCH TO LIGHTS & FAN 20.0 1 FA. 1,5 CLG. VFY. REQUIREMENTS w/SHOP DRAWINGS E67 FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF COUNTER & CAP FOR FUTURE USE E71 CONNECTION TO J-BOX IN ITEM: 71 TWO TIER PASS SHELF FROM E71 FROM E67 TO J-BOX IN ITEM: 71 TWO TIER PASS SHELF FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF'S COUNTER FROM E67 MAKE FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF COUNTER FROM E67 REACH-IN U/C REFRIGERATOR - NEMA 5-15P - E.C. TO EXTEND, INSTALL & MAKE FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF COUNTER JB E85 120 EXHAUST HOOD - E.C. INTERWIRE LIGHTS & FANS TO SWITCH (MOUNT SWITCH TO HOOD FACE) 15.0 1 FA 1,5 CLG JB E87 120 FIRE SUPPRESSION SYSTEM 1 96" 1 WALL 15.0 CKT. DR 65 120 REFRIGERATED SANDWICH UNIT - NEMA 5-15P - E.C. TO EXTEND, INSTALL 7.3 1 -6,8 FROM E67 & MAKE FINAL CONNECTION TO J-BOX IN ITEM: 67 CHEF COUNTER 0.20 FINAL CONNECTIONS TO ITEMS: 65, 66, 73, 79 & 83 EA. EA. E91A DR E103 120 CONVENIENCE OUTLET (2) RIP'S 8.0 1 50" 8 WALL EA. FROM JB E91B 120 TWO-TIER OVER SHELF - E.C. TO EXTEND & MAKE FINAL CONNECTION TO (2) ITEM: 102 VFY. 1 VFY. 69" 1,5 WALL JB E105.1 120 1 1,5 JB E107 120 GLASS WASHER - VFY. REQUIREMENTS w/OWNER 16.0 1 1 E109 DR E113 120 10.0 1 DR E118 120 REFRIGERATED BACK BAR CABINET - NEMA 5-15P 5.5 1 0.25 12" 6 WALL DR E119 120 MUG CHILLER 5.0 1 0.20 12" 6 WALL EA. JB 120 BLENDER STATION - E.C. TO WIRE FROM J-BOX TO OUTLET MOUNTED ON BLENDER STATION 15.0 1 1 6 BEV. GUN/CARBONATOR - VFY. REQUIREMENTS w/VENDOR SPO E126 208 COFFEE/TEA BREWER - VFY. REQUIREMENTS w/VENDOR 13.0 1 2.65 50" 6,8 WALL JB E137 208 ICE CUBER 10.2 1 72" 1 WALL DR E121 120 P.O.S. UNIT - VFY. REQUIREMENTS w/OWNER 1 6 DATA " DATA PORT - VFY. REQUIREMENTS w/OWNER 8 15.0 50" WALL 50" WALL CKT. DR E128 120 SODA/ICE DISPENSER - VFY. REQUIREMENTS w/VENDOR 10.0 1 12" 6 WALL JB E132 120 WALK-IN BEER COOLER EVAP. COIL - VFY. REQUIREMENTS w/SHOP DRAWINGS 1.16 1 FA 1 CLG JB E131 120 15.0 1 FA 1,5 CLG VALVE & OTHER DISCONNECTS AS NEEDED. WALK-IN BEER COOLER - E.C. TO INTERWIRE SWITCH, LIGHTS, PRESSURE RELIEF - E133 -DELETED - - -- EA. DR E24 120 SODA SYSTEM - VFY. REQUIREMENTS w/VENDOR 1 78" 6 WALL 20.0 CKT. UP 4" 10.1 3.61 38" - - 31.8 2 15.0 37" WALL BAR PLUG MOULD - E.C. TO SUPPLY & INSTALL ALONG UNDERSIDE OF BAR TOP 2 2 12" WALL 12" WALL 2 12" WALL J J V S J J J J J J S V J J J S E 4 E 3A E 3B E 12 E 8 E 18 E 23 E 32 E 33 E 37 E 37 E 41 E 43A E.C. TO INTERWIRE FIRE PROTECTION SYSTEM TO SHUNT TRIP BREAKERS IN MAIN PANEL BOX & FIRE CONTROL CENTER, (IF REQUIRED BY CODE). E 43B E 24 FS3 Electrical Rough-in Plan & Schedule ELECTRICAL ROUGH-IN PLAN (MAIN LEVEL GRILL/CATERING KITCHEN) SCALE: 1/4" = 1'-0" 5) REQUIRES INTERWIRING BETWEEN CONTROLS AND EQUIPMENT. 4) DIRECT SERVICE TO CIRCUIT BREAKER PANEL INCLUDED WITH EQUIPMENT. 8) OUTLET FURNISHED & INSTALLED BY ELECTRICAL CONTRACTOR. 9) OUTLET FURNISHED WITH EQUIPMENT & INSTALLED BY ELECTRICAL CONTRACTOR. 7) CORD & PLUG FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 12) FLEX OUT OF WALL @ ROUGH-IN POINT (NO J-BOX REQ'D) 11) FINAL CONNECTION BY ELECTRICAL CONTRACTOR TO PRE-WIRED JUNCTION 10) EQUIPMENT INSTALLED IN COUNTER & WIRED BY MANUFACTURER. BOX OUTLET IN COUNTER 1) DIRECT TO JUNCTION BOX ON EQUIPMENT. 3) DIRECT TO JUNCTION BOX THROUGH DISCONNECT. 2) DIRECT TO OUTLETS INCLUDED WITH DISCONNECT. 6) CORD & PLUG FURNISHED WITH EQUIPMENT. CONNECTION TYPES PHASE SWITCH SYMBOLS & ABBREVIATIONS DUPLEX RECEPTACLE SPECIAL PURPOSE OUTLET FLOOR OUTLET ROUGH-IN POINT JUNCTION BOX AMP KILOWATT FLEX ABOVE FINISHED FLOOR HORSE POWER P.O.S. POWER/DATA PORT FO HP AFF KW AMP FLEX DR/DATA PH SW RIP SPO DR JB FROM ABOVE FA CEILING CLG STUB UP 4" TO JUNCTION BOX STUB UP 4" STUB UP 4" TO FLOOR MOUNTED OUTLET STUB UP 4" STUB UP 4" TO FLOOR MOUNTED SPECIAL PURPOSE OUTLET STUB UP 4" JUNCTION BOX MOUNTED IN EQUIPMENT JB DUPLEX RECEPTACLE MOUNTED IN/ON EQUIPMENT DR DROP CORD - PROVIDED & INSTALLED BY E.C. JB ELECTRICAL CONTRACTOR E.C. ELECTRICAL NOTES: 1. ALL ROUGH-INS SHOWN RELATE TO FOOD SERVICE EQUIPMENT ONLY. SEE ARCHITECTURAL/ENGINEERING PLANS FOR ADDITIONAL ELECTRICAL REQUIREMENTS. 2. FINAL CONNECTIONS TO ALL EQUIPMENT BY ELECTRICAL CONTRACTOR, INCLUDING MATERIALS. 3. ALL LOADS INDICATED ARE ACTUAL AND NOT CIRCUIT BREAKER SIZE UNLESS OTHERWISE NOTED. 4. ALL CONVENIENCE OUTLETS TO BE SET HORIZONTALLY. 5. ALL ROUGH-IN HEIGHTS INDICATED FROM FLOOR TO THE CENTER LINE OF THE OUTLET. FLOOR ROUGH-INS TO BE STUBBED UP 4" ABOVE FINISHED FLOOR OR CURB. ALL FLOOR OPENINGS ARE TO BE SEALED WATERTIGHT. 6. ELECTRICAL CONTRACTOR TO PROVIDE SHUNT TRIP BREAKERS FOR EQUIPMENT UNDER HOOD AND INTERWIRE TO FIRE PROTECTION SYSTEM, PER LOCAL CODE. 7. FINAL CONNECTIONS TO EQUIPMENT JUNCTION BOX OR PULL-BOX AND ALL ELECTRICAL WORK FROM PANEL BOARDS, TO BE BY THE ELECTRICAL CONTRACTOR. 8. VERIFY ALL ELECTRICAL ROUGH-INS AND LOCATIONS WITH OWNER, VENDOR OR G.C. ON EXISTING EQUIPMENT OR OTHER EQUIPMENT NOT PROVIDED BY W.WEST. 9. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL THE FOLLOWING AS PER CODE. a. ALL JUNCTION BOXES, ELECTRICAL OUTLETS, COVER PLATES, SWITCHES, ECT., NOT BUILT INTO FIXTURES OR EQUIPMENT. ALL OUTLETS, JUNCTION BOXES, COVER PLATES, ETC., IN LAUNDRY AREAS, DISHROOM OR AS INDICATED ON SCHEDULES, MUST BE VAPOR PROOF, OR AS PER LOCAL CODE. b. ALL PLUGS & CORDS AS NOTED ON SCHEDULE. ALL CORDS SHALL BE N.E.M.A. RATED AND U.L. APPROVED FOR MANUFACTURED AND/OR FABRICATED EQUIPMENT. c. SHUNT-TRIP CIRCUIT BREAKERS OR DISCONNECTS FOR FIRE CONTROL SYSTEM SHUT-OFF OF FOOD SERVICE EQUIPMENT BELOW HOODS/VENTILATORS AS REQUIRED BY N.F.P.A. 96 CODE OR LOCAL CODE. d. DISCONNECTS OR OTHER DEVICES AS REQUIRED BY CODES. e. ALL REQUIRED BULBS FOR FIXTURES. f. PLUG MOLDS SUPPLIED & INSTALLED WHERE INDICATED. 10. WHEN APPLICABLE, ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT WIRING, INSTALL ELECTRICAL COMPONENTS AND INTERWIRE BETWEEN THE FOLLOWING: a. REMOTE REFRIGERATION EQUIPMENT TO EVAPORATOR COILS AND FOR DEFROST CONTROLS. b. CONTROL PANELS TO VENTILATORS AND EXHAUST/ SUPPLY FANS PER MANUFACTURER'S INSTRUCTIONS. c. KITCHEN EXHAUST HOOD/VENTILATORS TO FIRE CONTROL SYSTEM AND HOOD CONTROLS. d. MODULE COUNTERS AND COMPONENTS OR EQUIPMENT MOUNTED ON COUNTERS. GENERAL WALK-IN NOTES: 1. E.C. TO VERIFY EXACT SIZE & LOCATION OF COMPRESSORS FOR WALK-IN BOXES W/MECHANICAL CONTRACTOR. 2. E.C. TO MOUNT & INTERWIRE VAPOR-PROOF OR FLUORESCENT LIGHTS, WHICHEVER PROVIDED, PER SPEC.. RUN CONDUIT ON EXTERIOR TOP OF WALK-IN BOXES. LIGHTS FOR WALK-INS PER SPEC. 3. E.C. TO SUPPLY & MOUNT SERVICE DISCONNECTS @ ALL WALK-IN CONNECTIONS. Scale:As Noted Sheet Number: Drawn By GENERAL NOTE These plans are the property of W.West and use of these plans without the written consent of W.West is prohibited. No Responsibility is assumed by W.West for deviations from these drawings. Sheet Name: Food Service Design/Planning Designer/Project Manager 9355 Northfield Blvd. Denver, CO 80238 Phone: 303.289.9378 Fax: 303.289.9505 Revisions: 1 2 3 4 5 Project Number: Tim Trujillo Vail Golf Clubhouse Vail, Colorado T15007 J.V. J.V. 07-16-15 Permit Set Equipment & Furnishings Co. Checked By Date: 08-18-15 Permit Update Revision #2 ELECTRICAL ROUGH-IN PLAN (LOWER LEVEL SUPPORT KITCHEN) SCALE: 1/4" = 1'-0" 02/03/16