HomeMy WebLinkAboutA1.pdfREF.
REF.
REF.
UNIT TO BE
REMODELED
1 1
1 1
SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0"
PROPOSED PARTIAL SOUTH ELEVATION 5
EXISTING PARTIAL SOUTH ELEVATION
4
T.O. SLAB
SECOND FLOOR
EL. 61'-0"
T.O. SLAB
THIRD FLOOR
EL. 71'-0"
T.O. SLAB
LOFT
EL. 79'-0"
T.O. SLAB
SECOND FLOOR
EL. 61'-0"
T.O. SLAB
THIRD FLOOR
EL. 71'-0"
T.O. SLAB
LOFT
EL. 79'-0"
1
2
2
01
02 04 05 03
1
A-2
4
A-2
3
A-2
2
A-2
4
A-2
2
A-2
3
A-2
NEW METAL CLAD WOOD
EGRESS WINDOW CENTERED
ON EXISTING AWNING
WINDOW ASSEMBLY BELOW
EXISTING AWNING WINDOW
TO REMAIN
LINE OF REMOVED EXISTING
AWNING WINDOW
IN-FILL RATED WALL
CONSTRUCTION ON EACH
SIDE OF NEW WINDOW
NEW RECESSED FIRE RATED
EXTERIOR WALL
CONSTRUCTION
LINE OF EXISTING BALCONY
OPENING
EXISTING RECESSED
BALCONY AND WALL
CONSTRUCTION TO REMAIN
PAINTED GALVANIZED SHEET
METAL FLASHING OVER SELF
ADHESIVE WATERPROOF
MEMBRANE ON TAPERED
TREATED WOOD SILL BOARD
IN-FILL RATED WALL
CONSTRUCTION
PORTION OF EXISTING
CONCRETE DECK SLAB
EXTENSION TO BE REMOVED
NEW METAL CLAD WOOD
WINDOW
BEDROOM 2
BEDROOM 1
BATH 2
BATH 1
LIVING ROOM
KITCHEN LAUNDRY
COATS
MECH.
STORAGE
UP
ADJACENT
UNIT
ADJACENT
UNIT
40' - 0"
28' - 4"
EDGE OF CONCRETE DECK
PROJECTION BELOW
WOOD RAILING
ACCESS PANEL
FIREPLACE
FLUE FROM
UNIT BELOW
BEDROOM 2
BEDROOM 1
BATH 2
BATH 1
LIVING ROOM
KITCHEN LAUNDRY
COATS
MECH.
STORAGE
UP
ADJACENT
UNIT
ADJACENT
UNIT
40' - 0"
28' - 4"
PORTION OF CONCRETE DECK
SLAB EXTENSION TO BE REMOVED -
VERIFY AMOUNT FOR WALL
SHEATHING AND EIFS INSULATION
BOARD TO PASS BY.
SEE NOTE 2.
WOOD RAILING AND
STUCCO WALL ELEMENT
BELOW TO BE REMOVED
ACCESS DOOR
FIREPLACE
FLUE FROM
BELOW TO
REMAIN
WINDOW AND PORTION OF
WALL BELOW TO BE REMOVED
DOOR AND WOOD
SIDING TO BE
REMOVED
BALCONY
PORTION OF FIREPLACE FLUE
ENCLOSURE TO BE REMOVED
LIGHT FIXTURE
TO BE REMOVED
EXISTING DOOR, WALL,
AND WOOD SIDING TO
BE REMOVED
REMOVE COUNTER
TOP AND LOWER
CABS.
REMOVE PORTION
OF WALL
BEDROOM 2
BEDROOM 1
BATH 2
BATH 1
LIVING ROOM
KITCHEN LAUNDRY
COATS
MECH.
STORAGE
UP
ADJACENT
UNIT
ADJACENT
UNIT
40' - 0"
28' - 4"
REMOVE COUNTER
TOP AND LOWER
CABS.
REMOVE PORTION
OF WALL
S
S
E E T
EE
E E S
S
ELEC. BASEBOARD HEAT TO REMAIN
NEW GAS APPLIANCE
FIREPLACE
NEW THIN-STONE SURROUND
NEW HEARTH W/ TILE TOP
& STONE VENEER
NEW SHAFT WALL
CONSTRUCTION
LEVELING MATERIAL
TO BE APPLICED TO
EXISTING SLOPING
CONC. SLAB
5/8" TYPE "X"
DRYWALL TO BE
ADDED TO WALL
NEW PANEL ACCESS
8' - 0" 8' - 0" 5' - 10 1/2" 5' - 10 1/2"
05 04 03 02 01
PAINTED GALV. SHEET METAL FLASHING
OVER SELF-ADHESIVE WATERPROOF
MEMBRANE ON TAPERED TREATED
WOOD SILL AT EXISTING CONC. DECK
PROJECTION BELOW.
NEW 10 FT. ELECTRIC
BASEBOARD HEATER
NEW WALL CONSTRUCTION
NEW WALL CONSTRUCTION TO IN-
FILL OPENING FROM REMOVED
WINDOWS
VERIFY HEIGHT
A.F.F. W/ OWNER
VERIFY HEIGHT
A.F.F. W/ OWNER
9
5
EXISTING BALCONY CEILING
REFER TO BUILDING CODE
NOTE NO. 9 ON SHEET A-O
BALCONY WEST WALL
REFER TO 8
3
2
1
4
VERIFY LOCATION OF WINDOW W/ HOA PRIOR TO
FRAMING OPENING.
PROTECT GARAGE ENTRY MEMBRANE
SEE NOTE 10
970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631
www.martinmanleyarchitects.com
Project number Date REVISIONS
7/28/2015 12:51:38 PM
A-1 PLANS & ELEVS xxxx Snow Fox Condos Unit 304
Balcony Enclosure 7-28-15 1030 Lions Ridge Loop #304 Lions Ridge Filing 1, Vail, CO No. Description Date
1/4" = 1'-0"
1
MAIN LEVEL - EXISTING
1/4" = 1'-0" 2
MAIN LEVEL - DEMO
1/4" = 1'-0" 3
MAIN LEVEL - PROPOSED
1. REFER TO GENERAL CONSTRUCTION NOTES 5,6,7 ON
SHEET A-O CONCERNING ELECTRICAL AND LIGHTING
DISPLAYED ON THIS PLAN.
2. VERIFY LOCATION OF ALL ELECTRICAL RECEPTACLES,
LIGHT FIXTURES, SWITCHES, AND TV JACKS WITH THE
OWNER PRIOR TO INSTALLING WIRING.
ADDITION - SQUARE FOOTAGE AREA
ADDED FLOOR AREA = 156 SQ. FT.
INCLUDING FIREPLACE FLUE ENCLOSURE.
NOTE: VERIFY IF THE EXISTING SMOKE DETECTOR OUTSIDE THE BEDROOMS
IS ALSO A CARBON MONOXIDE DETECTOR AND REPLACE AS REQUIRED TO
PROVIDE CARBON MONOXIDE DETECTION.
PERMIT SET: 7-28-15 08/05/15