HomeMy WebLinkAboutA1.pdfREF. REF. REF. UNIT TO BE REMODELED 1 1 1 1 SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" PROPOSED PARTIAL SOUTH ELEVATION 5 EXISTING PARTIAL SOUTH ELEVATION 4 T.O. SLAB SECOND FLOOR EL. 61'-0" T.O. SLAB THIRD FLOOR EL. 71'-0" T.O. SLAB LOFT EL. 79'-0" T.O. SLAB SECOND FLOOR EL. 61'-0" T.O. SLAB THIRD FLOOR EL. 71'-0" T.O. SLAB LOFT EL. 79'-0" 1 2 2 01 02 04 05 03 1 A-2 4 A-2 3 A-2 2 A-2 4 A-2 2 A-2 3 A-2 NEW METAL CLAD WOOD EGRESS WINDOW CENTERED ON EXISTING AWNING WINDOW ASSEMBLY BELOW EXISTING AWNING WINDOW TO REMAIN LINE OF REMOVED EXISTING AWNING WINDOW IN-FILL RATED WALL CONSTRUCTION ON EACH SIDE OF NEW WINDOW NEW RECESSED FIRE RATED EXTERIOR WALL CONSTRUCTION LINE OF EXISTING BALCONY OPENING EXISTING RECESSED BALCONY AND WALL CONSTRUCTION TO REMAIN PAINTED GALVANIZED SHEET METAL FLASHING OVER SELF ADHESIVE WATERPROOF MEMBRANE ON TAPERED TREATED WOOD SILL BOARD IN-FILL RATED WALL CONSTRUCTION PORTION OF EXISTING CONCRETE DECK SLAB EXTENSION TO BE REMOVED NEW METAL CLAD WOOD WINDOW BEDROOM 2 BEDROOM 1 BATH 2 BATH 1 LIVING ROOM KITCHEN LAUNDRY COATS MECH. STORAGE UP ADJACENT UNIT ADJACENT UNIT 40' - 0" 28' - 4" EDGE OF CONCRETE DECK PROJECTION BELOW WOOD RAILING ACCESS PANEL FIREPLACE FLUE FROM UNIT BELOW BEDROOM 2 BEDROOM 1 BATH 2 BATH 1 LIVING ROOM KITCHEN LAUNDRY COATS MECH. STORAGE UP ADJACENT UNIT ADJACENT UNIT 40' - 0" 28' - 4" PORTION OF CONCRETE DECK SLAB EXTENSION TO BE REMOVED - VERIFY AMOUNT FOR WALL SHEATHING AND EIFS INSULATION BOARD TO PASS BY. SEE NOTE 2. WOOD RAILING AND STUCCO WALL ELEMENT BELOW TO BE REMOVED ACCESS DOOR FIREPLACE FLUE FROM BELOW TO REMAIN WINDOW AND PORTION OF WALL BELOW TO BE REMOVED DOOR AND WOOD SIDING TO BE REMOVED BALCONY PORTION OF FIREPLACE FLUE ENCLOSURE TO BE REMOVED LIGHT FIXTURE TO BE REMOVED EXISTING DOOR, WALL, AND WOOD SIDING TO BE REMOVED REMOVE COUNTER TOP AND LOWER CABS. REMOVE PORTION OF WALL BEDROOM 2 BEDROOM 1 BATH 2 BATH 1 LIVING ROOM KITCHEN LAUNDRY COATS MECH. STORAGE UP ADJACENT UNIT ADJACENT UNIT 40' - 0" 28' - 4" REMOVE COUNTER TOP AND LOWER CABS. REMOVE PORTION OF WALL S S E E T EE E E S S ELEC. BASEBOARD HEAT TO REMAIN NEW GAS APPLIANCE FIREPLACE NEW THIN-STONE SURROUND NEW HEARTH W/ TILE TOP & STONE VENEER NEW SHAFT WALL CONSTRUCTION LEVELING MATERIAL TO BE APPLICED TO EXISTING SLOPING CONC. SLAB 5/8" TYPE "X" DRYWALL TO BE ADDED TO WALL NEW PANEL ACCESS 8' - 0" 8' - 0" 5' - 10 1/2" 5' - 10 1/2" 05 04 03 02 01 PAINTED GALV. SHEET METAL FLASHING OVER SELF-ADHESIVE WATERPROOF MEMBRANE ON TAPERED TREATED WOOD SILL AT EXISTING CONC. DECK PROJECTION BELOW. NEW 10 FT. ELECTRIC BASEBOARD HEATER NEW WALL CONSTRUCTION NEW WALL CONSTRUCTION TO IN- FILL OPENING FROM REMOVED WINDOWS VERIFY HEIGHT A.F.F. W/ OWNER VERIFY HEIGHT A.F.F. W/ OWNER 9 5 EXISTING BALCONY CEILING REFER TO BUILDING CODE NOTE NO. 9 ON SHEET A-O BALCONY WEST WALL REFER TO 8 3 2 1 4 VERIFY LOCATION OF WINDOW W/ HOA PRIOR TO FRAMING OPENING. PROTECT GARAGE ENTRY MEMBRANE SEE NOTE 10 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/28/2015 12:51:38 PM A-1 PLANS & ELEVS xxxx Snow Fox Condos Unit 304 Balcony Enclosure 7-28-15 1030 Lions Ridge Loop #304 Lions Ridge Filing 1, Vail, CO No. Description Date 1/4" = 1'-0" 1 MAIN LEVEL - EXISTING 1/4" = 1'-0" 2 MAIN LEVEL - DEMO 1/4" = 1'-0" 3 MAIN LEVEL - PROPOSED 1. REFER TO GENERAL CONSTRUCTION NOTES 5,6,7 ON SHEET A-O CONCERNING ELECTRICAL AND LIGHTING DISPLAYED ON THIS PLAN. 2. VERIFY LOCATION OF ALL ELECTRICAL RECEPTACLES, LIGHT FIXTURES, SWITCHES, AND TV JACKS WITH THE OWNER PRIOR TO INSTALLING WIRING. ADDITION - SQUARE FOOTAGE AREA ADDED FLOOR AREA = 156 SQ. FT. INCLUDING FIREPLACE FLUE ENCLOSURE. NOTE: VERIFY IF THE EXISTING SMOKE DETECTOR OUTSIDE THE BEDROOMS IS ALSO A CARBON MONOXIDE DETECTOR AND REPLACE AS REQUIRED TO PROVIDE CARBON MONOXIDE DETECTION. PERMIT SET: 7-28-15 08/05/15