Loading...
HomeMy WebLinkAboutA000.pdfINTERNATIONAL BUILDING CODE 2012 PROJECT SUMMARY: Zoning: MULTI FAMILY RESIDENTIAL Code: ARCHITECT: K.H. WEBB ARCHITECTS P.C. 710 W. LIONSHEAD CIRCLE, UNIT A VAIL, CO 81657 PH. 970.477.2990 CONTACT: KYLE H. WEBB COOPER RESIDENCE BUILDING D UNIT #310 RENOVATION NORTHWOODS CONDOMINIUMS VAIL, COLORADO PROJECT TEAM: GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. ARCHITECTURAL A 001 1/4" 3RD FLOOR DEMO PLAN A 100 1/4" 3RD FLOOR PROPOSED PLAN A 101 1/4" 3RD FLOOR PROPOSED ELECTRICAL PLAN A 102 1/4" INTERIOR BATHROOM ELEVATIONS A 103 1/4" INTERIOR LIVING ROOM ELEVATIONS A 2.16 1/4" BUILDING ELEVATION A 2.17 1/4" BUILDING ELEVATION A 404 1/4" BUILDING SECTION A 600 WINDOWS/DOORS SCHEDULE DRAWING INDEX Detail Area Reference Elevation Reference Section Cut Reference Large Area Detail Reference 12/31/1999 Material Tag Revision Symbol Detail Cut Reference Grid Bubble Revision Cloud Elevation Symbol SYMBOLS: RESIDENTIAL GROUP R-2 Occupancy Classification: GENERAL CONTRACTOR: R.A. NELSON 51 EAGLE RD #2 AVON, CO 81620 PH. 970.949.5152 PERMIT 06.29.15 STRUCTURAL ENGINEER: KRM CONSULTANTS 101 EAGLE RD. 2ND FLOOR AVON, CO 81620 PH. 970.949.9391 FX. 970.949.1577 CONTACT: KIMBERLY MCGHEE STRUCTURAL 6¬SPEC 6¬1/4" MAIN PROPOSED PLAN 06.29.15 ELECTRICAL (¬ELECTRICAL EQUIPMENT & PANEL SCHEDULES (¬ELECTRICAL PLAN MECHANICAL, ELECTRICAL & LIGHTING DESIGN SERVICES: AEC, ARCHITECTURAL ENGINEERING CONSULTATNS, INC. 40801 US HWY 6& 24, STE 214 AVON, CO 81620 PH. 970.748.8520 CONTACT: TAYLOR CRITCHLOW PLUMBING 3¬PLUMBING RISER ANALYSIS AND SPECIFICATIONS 3¬PLUMBING FLOOR PLAN PROJECT: 710 WEST LIONSHEAD CIRCLE - UNIT A VAIL., COLORADO 81657 970.477.2990 BUILDING D UNIT #310 RENOVATION DRAWN BY: DATE: REVISIONS: N310 NORTHWOODS CONDOMINIUMS VAIL , CO CR REVISION 1 07.20.15 08.25.15 FOR CONSTRUCTION TYPE IIA (Automatic Sprinkler Throughout) Building Construction Type: 5 (1 Garage Level Below Grade) Stories Above Grade Plane: 09/02/15