Loading...
HomeMy WebLinkAboutB15-0292 A000 Cover.pdfGENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. RESPONSE TIME SHALL BE ON A CASE BY CASE BASIS AND SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE UNIFORM BUILDING CODE 1997 EDITION. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. 21. CONTRACTOR TO COMPLY WITH SPECIAL INSPECTIONS- IBC-1704.1.1 BUILDING PERMIT REQUIREMENT. 22. THE POOL AND SPA DRAWINGS SHALL BE INCLUDED AS A DEFERED PERMIT SET A000 COVER SHEET A3.0 PHASE I NORTH ELEVATIONS 3 16"=1'-0" A3.1 PHASE I SOUTH & WEST ELEVATIONS 3 16"=1'-0" A3.2 PHASE I & II ELEVATIONS 3 16"=1'-0" A3.3 PHASE II ELEVATIONS 3 16"=1'-0" A4.7 WINDOW & DOOR DETAILS VARIES A4.9 DETAILS VARIES A4.10 SECTIONS 1/2"=1'-0" DRAWING INDEX: INTERNATIONAL BUILDING CODE 2012 Main Occupancy Classification and Type of Construction - R-2- Type III- B Automatic sprinkler system Table 503- Phase I/Four stories plus basement, Phase II/ Four Stories plus basement 8QGHUVTXDUHIHHWRI´DUHDEXLOGLQJµSHUIORRUVHHDWWDFKHGDOORZDEOHIORRUDUHDFDOFXODWLRQV See A001- For area calculations. Other Occupancy Classifications shall be classified under Table 302.1.1 Incidental Use areas as follows: Room: Separation: Boiler Room Provide automatic fire-extinguishing system/ plus smoke separation. Parking Garage 1 hour and provide automatic fire-extinguishing system/ plus smoke separation. Waste and Linen collection Room Provide automatic fire-extinguishing system/ plus smoke separation. Storage 100 sq ft or over- provide automatic fire-extinguishing system/ plus smoke separation. Type III B- See table 601 for complete fire-resistance rating Main Ratings Per Code: Structural frame- 0 hr (Table 601) Exterior (Non Bearing) Walls- 1 hr (Table 602) Interior Non Bearing- 0 hr (Table 601) Exterior Bearing Walls- 2 hr (Table 601) Roof Construction- 0 hr (Table 601) Corridors serving R-2- 0.5 hr Walls Separating Dwelling Units- 1 hr Hor. Floor/ Ceiling Assemblies- 0 hr Shaft Assemblies- 1 & 2 hr (707.4) Exit Stair Enclosures- 2 hr Non- Combustible material- Concealed Soffit, Overhang, Decks, Lobby Entry, Trash Dumpster, and Over Framed Roofs. P R O J E C T : 710 W. LIONSHEAD CIR. UNIT A VAIL . CO 81657 970.477.2990 970.477.2965(F) D R A W N B Y : D A T E : R E V I S I O N S : 2329/ 2330 LODGE AT LIONSHEAD LoT 7 Block 1, Vail Lionshead Filing 1/ 380 E. Lionshead Cir. Town of Vail, Eagle County Colorado Residing Project HB/GM ARCHITECT: K.H. WEBB ARCHITECTS P.C. 710 W. LIONSHEAD CIRCLE, UNIT A VAIL, CO 81657 PH. 970.477.2990 FX. 970.477.2965 info@khwebb.com CONTACTS: KYLE H. WEBB LODGE AT LIONSHEAD LOT 7 BLOCK 1, VAIL LIONSHEAD FILING 1 380 E. LIONSHEAD CIRCLE VAIL, COLORADO 81657 PROJECT TEAM: RESIDING PROJECT - PERMIT DOCUMENT SET 08.11.15 PROJECT CODE SUMMARY: Staging plan, traffic control plan and Pubic way Permit requried if use of bike path or right of way is needed for construction equipment or material delivery 09/03/15