Loading...
HomeMy WebLinkAboutwaterproofing design.pdfTEST PATCHES: THE MEMBRANE APPLICATION SHALL PROCEED ONLY AFTER THE SUCESSFUL COMPLETION OF TEST PATCH TO CHECK THE ADHESION OF THE MEMBRANE. APPLY A TEST PATCH OF MONOLITHIC MEMBRANE 6125 TO THE SURFACE AND CHECK ITS ADHESION PER THE INSTALLATION GUIDELINES OF AMERICAN HYDROTECH. FURNISH AND INSTALL A COMPLETED WATERPROOFING ASSEMBLY INCLUDING SURFACE CONDITIONER, A MONOLITHIC, RUBBERIZED ASPHALT MEMBRANE, PROTECTION COURSES, FLASHINGS, DRAINAGE MAT, AND RIGID INSULATION BOARD, WHERE REQUIRED. SUBMITTALS: A. CERTIFICATION SHOWING THAT ALL WATERPROOFING COMPONENTS ARE BEING SUPPLIED AND WARRANTED BY THE MANUFACTURER. B. THE WATERPROOFING CONTRACTOR SHALL SUBMIT THE FOLLOWING DOCUMENTATION: CERTIFICATION OR LICENSE BY THE MEMBRANE MANUFACTURER AS AN AUTHORIZED APPLICATOR OF THE PRODUCT FOR A MINIMUM OF FIVE (5) YEARS. C. UPON COMPLETION OF THE WORK, THE CONTRACTOR MUST SUPPLY THE OWNER WITH A SINGLE-SOURCE 10-YEAR WATERTIGHTNESS WARRANTY INCLUDES LABOR AND MATERIAL DIRECT FROM THE MANUFACTURER. D. MATERIAL DATA FOR: 1. MM6125-FR HOT, FLUID APPLIED, RUBBERIZED ASPHALT MEMBRANE WATERPROOFING SYSTEM AND RELATED COMPONENTS MANUFACTURED BY: AMERICAN HYDROTECH, INC. INCLUDING: SURFACE CONDITIONER FLEX FLASH UN FLEX FLASH F HYDROFLEX 30 1/8” HARDBOARD PROTECTION BOARD LAP SEALANT HYDRODRAIN 300 AND 700 2. GRACE ULTRA SHEET-APPLIED WATERPROOFING AND RELATED COMPONENTS MANUFACTURED BY: GRACE CONSTRUCTION, INC. INCLUDING: BITUTHENE PRIMER B2 LIQUID MEMBRANE 3000 PRE-CONSTRUCTION CONFERENCES: THE MANUFACTURER WILL MEET WITH THE NECESSARY PARTIES AT THE JOBSITE TO REVIEW AND DISCUSS PROJECT CONDITIONS AS IT RELATES TO THE INTEGRITY OF THE WATERPROOFING ASSEMBLY. DELIVERY, STORAGE AND HANDLING: DELIVER MATERIALS IN ORIGINAL UNOPENED CONTAINERS OF PACKAGING CLEARLY LABELED WITH MANUFACTURER'S NAME, BRAND NAME, INSTRUCTION FOR USE AND ALL IDENTIFYING NUMBERS. MATERIALS SHALL BE STORED IN A NEAT, SAFE MANNER, NOT TO EXCEED THE ALLOWABLE STRUCTURAL CAPACITY OF THE STORAGE AREA. STORE MATERIALS IN A CLEAN, DRY AREA PROTECTED FROM WATER AND DIRECT SUNLIGHT. STORE ALL ADHESIVES AT TEMPERATURES BETWEEN 60°F (15.5°C) AND 80°F (26.6°C). IF EXPOSED TO LOWER TEMPERATURES, RESTORE MATERIALS TO 60°F (15.5°C) MINIMUM TEMPERATURE BEFORE USING. PROJECT CONDITIONS: APPLICATION OF THE MEMBRANE SHALL NOT COMMENCE NOR PROCEED DURING INCLEMENT WEATHER. ALL SURFACES TO RECEIVE THE MEMBRANE SHALL BE FREE OF WATER, DEW, FROST, SNOW AND ICE. APPLICATION OF MM6125-FR SYSTEM SHALL NOT COMMENCE NOR PROCEED WHEN THE AMBIENT TEMPERATURE IS BELOW 0°F. APPLICATION OF ULTRA SYSTEM SHALL NOT COMMENCE NOR PROCEED WHEN AMBIENT TEMERATURE IS BELOW 40°F. DO NOT ALLOW WASTE PRODUCTS (PETROLEUM, GREASE, OIL, SOLVENTS, VEGETABLE OR MINERAL OIL, ANIMAL FAT, ETC.) TO COME IN CONTACT WITH THE MEMBRANES. ANY EXPOSURE TO FOREIGN MATERIALS OR CHEMICAL DISCHARGES MUST BE PRESENTED TO MEMBRANE MANUFACTURER FOR EVALUATION TO DETERMINE ANY IMPACT ON THE WATERPROOF MEMBRANE ASSEMBLY PERFORMANCE. INSPECTION: CONCRETE DECK/WALL SURFACE CONDITION: SHALL BE CLEAN, FREE OF EXISTING WATERPROOFING AND DEBRIS, ASSURE ADEQUATE PROTECTION DURING INSTALLATION OF THE WATERPROOFING ASSEMBLY. THE WATERPROOFING CONTRACTOR SHALL EXAMINE ALL SURFACES TO RECEIVE THE WATERPROOFING ASSEMBLY TO VERIFY IT IS ACCEPTABLE AND PROPER FOR THE APPLICATION OF THE MEMBRANE USING THE AMERICAN HYDROTECH'S PRE-INSTALLATION & APPLICATION GUIDELINES. THE WATERPROOFING CONTRACTOR SHALL NOT PROCEED WITH THE INSTALLATION OF THE WATERPROOF MEMBRANE ASSEMBLY UNTIL ALL DECK DEFECTS HAVE BEEN CORRECTED. PREPARATION: ALL SURFACES MUST BE DRY, SMOOTH, FREE OF DEPRESSIONS, VOIDS, PROTRUSIONS, CLEAN AND FREE OF UNAPPROVED CURING COMPOUNDS, FORM RELEASE AGENTS AND OTHER SURFACE CONTAMINANTS. CONCRETE DECK MUST BE MONOLITHIC, SMOOTH, FREE OF VOIDS, SPALLED AREAS, LAITANCE, HONEYCOMBS, AND SHARP PROTRUSIONS. TEST PATCHES: THE MEMBRANE APPLICATION SHALL PROCEED ONLY AFTER THE SUCESSFUL COMPLETION OF TEST PATCH TO CHECK THE ADHESION OF THE MEMBRANE. APPLY A TEST PATCH OF MONOLITHIC MEMBRANE 6125 TO THE SURFACE AND CHECK ITS ADHESION PER THE INSTALLATION GUIDELINES OF AMERICAN HYDROTECH. INSTALLATION OF SURFACE CONDITIONER: THE USE OF SURFACE CONDITIONER TO THE EXISTING WALL SURFACES AND CONCRETE SHOULD DETERMINED. CONFIRMATION OF THIS SHALL BE DETERMINED BY THE MANUFACTURER. IF CONDITIONER IS DEEMED APPROPIATE BY THE MANUFACTURER, USING A HAND HELD SPRAYER EVENLY AT A RATE OF 300 TO 600 SF/GALLON DEPENDING ON SURFACE TEXTURE. SURFACE CONDITIONER SHOULD "TAN" THE SURFACE, NOT BLACKEN IT. ALLOW SUFFICIENT TIME FOR THE SURFACE CONDITIONER TO THOROUGHLY DRY PRIOR TO THE MEMBRANE APPLICATION. INSTALLATION OF THE HOT, LIQUID-APPLIED MEMBRANE: THE MEMBRANE SHALL BE HEATED IN DOUBLE JACKETED, OIL BATH OR HOT AIR MELTER WITH MECHANICAL AGITATION, SPECIFICALLY DESIGNED FOR THE PREPARATION OF A RUBBERIZED ASPHALT MEMBRANE. HEAT MEMBRANE UNTIL MEMBRANE CAN BE DRAWN-FREE FLOWING AT A TEMPERATURE RANGE BETWEEN 350°F AND 375°F. MEMBRANE EXCEEDING 400°F SHALL NOT BE USED AND SHALL BE PROPERLY DISPOSED OF. ALL DETAILING AND FLASHING SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD GUIDELINE DETAILS AND THESE DRAWINGS. ALL DETAILING AND FLASHING SHALL BE COMPLETED BEFORE INSTALLING THE MEMBRANE OVER THE FIELD OF THE SUBSTRATE. APPLY THE RUBBERIZED ASPHALT MEMBRANE AT A RATE TO PROVIDE A CONTINUOUS, MONOLITHIC COAT OF 215 MIL MINIMUM, BUT NOT LESS THAN 180 MIL THICKNESS. INSTALL ULTRA SHEET WATERPROOFING FLASHING AT EDGES AND TERMINATIONS AS SHOWN IN THE DETAILS PRIOR TO INSTALLATION OF THE PROTECTION SHEET TO ENSURE MEMBRANE-TO-MEMBRANE ADHESION. EMBED THE PROTECTION SHEET INTO THE MEMBRANE WHILE IT IS STILL HOT TO INSURE A GOOD BOND. OVERLAP ADJOINING SHEET EDGES (DRY) A MINIMUM OF 2"-3" (50.8 MM - 76.2 MM) TO INSURE COMPLETE COVERAGE. INSTALL RIGID PROTECTION BOARD OVER EMBEDDED PROTECTION SHEET, STAGGER THE JOINTS AND INSTALL 90 DEGREES TO THE PROTECTION SHEET. WATER TEST: THE WATERPROOFING APPLICATION SHALL SUCESSFULLY PASS A 48 HOUR WATER TEST. THE TEST SHALL BE AS FOLLOWS: FOR EACH DECK POND WATER TO A MINIMUM DEPTH OF 2" FOR A PERIOD OF 48 HOURS TO CHECK THE INTEGRITY OF THE MEMBRANE INSTALLATION. DRAINAGE COURSE: INSTALL DRAINAGE COURSE ON HORIZONTAL AND VERTICAL SURFACES IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. LAYOUT AND POSITION DRAINAGE COURSE AND ALLOW TO LAY FLAT. CUT AND FIT DRAINAGE COURSE TO PERIMETER AND PENETRATIONS. WARRANTY: 10-YEAR WATERTIGHTNESS WARRANTY (JOINT LABOR AND MATERIALS)