HomeMy WebLinkAboutE002.pdf1 1 1 1 LIGHTING FIXTURE SCHEDULE PREPARED BY KAZIN & ASSOCIATES DESCRIPTION OF LUMINAIRE LUMINAIRE SPECIFICATION ID DESCRIPTION FINISH MOUNTING INFO MANUFACTURER CATALOG NUMBER LAMP(S) VOLTAGE A LED LINEAR PROFILE PER TENANT RECESSED ON-LIGHT KOOLED-UH #17-30-90-FL-1-AN LED: 7.5W/FOOT 120 B LED TRACK HEAD PER TENANT TRACK ON-LIGHT MICRO ON GLOBAL TRAC MICRO--26-30-84-NFL-GLO-1-3 33W LED 120 T 3-CIRCUIT TRACK PER TENANT SURFACE GLOBAL TRAC GLOBAL TRAC N/A 120 C 4' FLUORESCENT STRIP WHITE SURFACE COLUMBIA OR EQUAL CS4-128T5-EBU-CSWG4 (1) F28T5 120 E1 SURFACE MOUNTED OR SUSPENDED WET LOCATION DIFFUSER LUMINAIRE PER TENANT SURFACE OR PENDANT ON-LIGHT TUBIS LED 144L-4-PO-1-WB-SSC 44W LED 120 E2 SURFACE MOUNTED OR SUSPENDED WET LOCATION DIFFUSER LUMINAIRE PER TENANT SURFACE OR PENDANT ON-LIGHT TUBIS LED 155L-5-PO-1-WB-SSC 55W LED 120 NOTES: 1. PROVIDED HANGERS, ADAPTERS, INSTALLATION KITS, PARTS AND PIECES TO INSTALL THE SPECIFIED FIXTURE IN THE LOCATIONS SHOWN ON THE PLAN. 1 LIGHTING RELAY PANEL (LRP1) RELAY FED FROM CIRCUIT NUMBER LOAD (VA) LOCATION LOCAL CONTROL CONTROL DESCRIPTION 1 NE8 2 600 RETAIL - LED LINEAR PROFILE PUSHBUTTON MANUAL SWITCH ON, TIME SWITCH OFF, MANUAL SWITCH OVERRIDE 2 NE8 4 1683 RETAIL - TRACK PUSHBUTTON MANUAL SWITCH ON, TIME SWITCH OFF, MANUAL SWITCH OVERRIDE 3 NE8 6 1200 SIGN 4 1 LIGHTING CONTROL PANEL WITH INTEGRAL CLOCK. REFERENCE ELECTRICAL SPECIFICATIONS AND RELAY SCHEDULE FOR ADDITIONAL REQUIREMENTS. DIGITAL SWITCH - REFERENCE LIGHTING PLAN FOR QUANTITY, LOCATIONS AND NUMBER OF BUTTONS PER SWITCH. INCOMING CIRCUIT PER RELAY SCHEDULE SWITCHED CIRCUIT OUT TO LOAD PER RELAY SCHEDULE REFERENCE RELAY SCHEDULE FOR QUANTITY OF RELAYS 2 LIGHTING RELAY PANEL CONCEPTUAL ONE-LINE DIAGRAM NOT TO SCALE 1 PANEL NE8 MDC-L1 3,000A <9 ‘ : 35,000AIC MBE4 METER CENTER 800A <9 ‘ : 35,000AIC MIN 7[4-500kcmil CU] (2500A) 2[4-500kcmil CU, 1 #1/0 CU G] (760A) (4 #1/0, 1 #6G)2"C (150A) 1 PARTIAL ONE-LINE DIAGRAM NOT TO SCALE NOTES: 1. EQUIPMENT, WIRING, AND DEVICES SHOWN LIGHT ARE EXISTING AND SHOWN DARK ARE NEW UNLESS OTHERWISE NOTED. 2. NEW WIRING SHALL BE THHN/THWN-2 INSULATED COPPER UNLESS OTHERWISE NOTED. FAULT CURRENT CALCULATIONS (END OF CONDUCTOR) LOCATION DESCRIPTION (@ ISC END) STARTING ISC MINIMUM CONDUCTOR LENGTH PHASE MULTIPLIER VOLTAGE # OF CONDUCTOR SETS C VALUE ISC END @ PANEL NE8 37,664 125 1.73 208 1 8,295 6,584 ISC = 37,664 PER ORIGINAL ELECTRICAL DRAWINGS 800A METER CENTER LOAD SUMMARY LOAD DESCRIPTION LOAD 72.9kVA PANEL NE6 19.9kVA PANEL NE8 22.9kVA TOTAL LOAD 115.7kVA TOTAL AMPERAGE @ 321A VOLTAGE 208 PHASE 3 UTILITY COMPANY PAD MOUNTED TRANSFORMER <9 ‘ : 6(&21'$5< 1 NOT ISSUED FOR CONSTRUCTION UNLESS SIGNED THROUGH THE SEAL IN BLUE INK OR DIGITALLY SIGNED BY BRYAN KAZIN. LIMITED TO ELECTRICAL. 36628 Scale Project Number Date Drawn by Checked by The Arrabelle at Vail Square Building "D" Level Two Retail Vail, CO 81657 THIS BOX FOR TOV APPROVALS ONLY AS NOTED 24515 Arrabelle Tenant Finish Vail Resorts Retail 17 Sep 2015 BEK BEK No. Description Date E002 10/21/15 1 Revisions ONE-LINE & SCHEDULES 1 11/11/15