HomeMy WebLinkAboutE-100.pdfD/W WM DWR CONTROL EXHAUST FRIDGE DBL OVEN M/W TV TV GFCI GFCI T GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI DINING ROOM 104 KITCHEN 106 MASTER BATH 102 MASTER BED 103 ENTRY 100 BATH 2 108 BED 2 107 LIVING ROOM 105 TV BATH 3 101 N/R N/R N N/R N N N 1 2 3 4 CONNECT TO EXISTING 120V. CIRCUIT 2 CONNECT TO EXISTING 120V. CIRCUIT 4a "PP-P9B" (CONDO) "PP-CD16" "PP-CD15" "PP-CD12" "PP-CD11" "PP-CD10" "PP-CD7" "PP-CD6" "PP-CD5" "PP-CD3" "PP-CD2" 1000 AMPS DISTRIBUTION PANEL "DP-DC2" 208/120V., 3ɐ, 4 WIRE ISC = 18,000 100A3P 100A3P 100A3P 100A3P 100A3P 100A3P 100A3P 100A3P 100A3P 200A3P 60A3P 100A3P 100A3P SPARE SPARE 1000A3P 30A3P 300 KVA TRANSFORMER "TR-5" 480/208/120V., 3ɐ, 4 WIRE (K-4 RATED) TO 500A3P BREAKER IN 3000 AMP MAIN SWITCHBOARD "MSB-B", 480/277V., 3ɐ, 4 WIRE UNIT 1024 UNIT 8203 UNIT 7203 1. REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS, ELEVATIONS, DETAILS, ETC.. VERIFY MOUNTING HEIGHTS OF DEVICES AND ENSURE MINIMUM 24" HORIZONTAL SEPARATION PER UBC IN FIRE RATED DEMISING WALLS. PROVIDE FIRE-STOP OR ADDITIONAL RATED GYP BOARD AS REQUIRED. COORDINATE WITH FIRE DEPT./INSPECTOR AND G.C. 2. UNIT LIGHT FIXTURES TO BE SELECTED BY OWNER, RATED FOR INSULATED CEILINGS. ENSURE PROPER LOCAL SWITCHING. LIGHTING FURNISHED BY E.C. TO BE COORDINATED WITH CEILING TYPES, MECHANICAL WORK, STRUCTURAL MEMBERS, ETC. VERIFY FINISHES AND LOCATIONS OF CONTROLS. 3. COORDINATE PRE-WIRING OF T.V. COAX AND TELEPHONE JACKS WITH G.C. AND OWNER. VERIFY ALL WALL LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN. 4. PROVIDE RECEPTACLE LOCATIONS AND SPACING PER N.E.C. 210-52 THROUGHOUT. FIELD ADJUSTMENTS / MEASUREMENTS ARE REQUIRED TO COMPLY. COORDINATE ADDITIONAL STUD WALL BRACING IF REQUIRED FOR RECEPTACLE PLACEMENTS WITH G.C. IF APPLICABLE, VERIFY FLOOR OUTLET LOCATIONS WITH ARCHITECT. PROVIDE GFI RECEPTACLES WHERE REQUIRED BY CODE PER NEC 210.8. 5. PROVIDE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION IN DWELLING UNITS PER NEC 210.12. FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. VERIFY WITH LOCAL AUTHORITY HAVING JURISDICTION IF EXISTING BRANCH CIRCUITS SHALL COMPLY WITH NEC 210.12. 6. ALL CLOSET LIGHTING SHALL COMPLY WITH NEC 410.16. 7. ALL ELECTRICAL DEVICES AND LIGHT FIXTURE MOUNTING HEIGHTS SHALL COMPLY TO THE "FAIR HOUSING ACT": DUPLEXES +15" A.F.F., SWITCHES AT +46" A.F.F. VERIFY WITH OWNER. 8. FOR NEW RECEPTACLES, PROVIDE TAMPER RESISTANT RECEPTACLES THROUGHOUT DWELLING UNIT AS REQUIRED BY NEC 406.12 9. PROVIDE ACCURATE AND LEGIBLE PANEL INDEXES IDENTIFYING SPECIFIC PURPOSE OR USE OF CIRCUIT BREAKERS PER NEC 408.4. GENERAL NOTES - POWER: TV FOURPLEX WALL OUTLET TELEPHONE JACK DUPLEX WALL RECEPTACLE FLOOR DUPLEX RECEPTACLE TV / COAXIAL RECEPTACLE 220V WALL RECEPTACLE TELEPHONE & DATA JACK IN-FLOOR TELEPHONE JACK DATA JACK HARDWIRE BOX LOCATION-AS NOTED, EXISTING E NOTE: UNLESS OTHERWISE NOTED, ALL NEW RECEPTACLES SHALL MATCH EXISTING ELEVATIONS (AFF) NOTE: NOT ALL EXISTING RECEPTACLES ARE SHOWN. THOSE SHOWN ARE FOR REFERENCE AND ARE IN THE AREA OF CONSTRUCTION. DASHED FIXTURES INDICATES EXISTING TO BE REMOVE / DEMOLISHED OR RELOCATED. LEGEND - POWER: N = NEW FIXTURE R = RELOCATED DETAIL NOTES - POWER: 1 EXISTING ELECTRICAL PANEL TO BE RELOCATED AS SHOWN. EXTEND CONDUITS AND FEEDERS AS NECESSARY FOR NEW LOCATION. EXISTING RECEPTACLE TO BE RELOCATED TO NEW LOCATION AS SHOWN. EXTEND CONDUITS AND FEEDERS AND RECONNECT TO EXISTING BRANCH CIRCUIT. EXISTING RECEPTACLE TO BE REMOVED. ENSURE CIRCUIT CONTINUITY TO RECEPTACLES THAT ARE EXISTING TO REMAIN AND MAYBE AFFECTED BY DEMOLITION WORK. EXISTING WASHER/DRYER RECEPTACLES TO BE RELOCATED TO NEW WASHER/DRYER LOCATION. REFER TO DETAIL NOTE 4a. NEW LOCATION FOR WASHER/DRYER RELOCATED EXISTING PROVIDE NEW RECEPTACLES AT THIS LOCATION. REUSE CIRCUITS. 2 3 4 4a ISSUE DATE UNIT 7203 FOUR SEASONS RESORT & RESIDENCES VAIL, CO JMM CHK BY: SCALE: SHEET: JOB #: DRW BY: TITLE: DATE: COMMENT AS NOTED C3S,TNS UNIT 7203 REMODEL SEAL & SIGNATURE: CLIENT: Tom & Nancy Lacey Unit 7203 FOUR SEASONS VAIL 1 Vail Road VAIL, CO 81657 ARCHITECT: Creative Design Associates 434 BROADWAY, 5TH FLOOR NEW YORK, NY 10013 t. 212-748-8900 f. 212-748-7950 WESTERN US 4700 E BROMLEY LN, SUITE 105 BRIGHTON, CO 80601 t. 646-747-2171 c. 917-756-0057 dsorenson@ralcompanies.com INTERIOR DESIGN: Worth Interiors 30 BENCHMARK ROAD, SUITE 103 AVON, CO 81920 t. 970-949-9794 eddy@worthinteriors.com ELECTRICAL ENGINEER: C3S Incorporated 3212 WEST 45TH AVENUE DENVER, CO 80211 t. 303-480-5144 theresa@c3sengineeringinc.com 15-30 1 FOR PERMIT 09/17/2015 09/17/15 OF 2 POWER PLAN, ONE LINE, AND SCHEDULE 1E-100 NOT TO SCALE 2 EXISTING (PARTIAL) ONE LINE DIAGRAM ALL DASHED LINES INDICATE EXISTING TO REMAIN U.O.N. ALL SOLID LINES INDICATE NEW EQUIPMENT ALL HIDDEN LINES INDICATE FUTURE EQUIPMENT. ALL SHADED AREAS INDICATE EXISTING TO BE REMOVED. SCALE: 1/4" = 1'-0" 1 POWER PLAN - UNIT 7203 10/07/15