HomeMy WebLinkAboutE-200.pdfS
S
S
S
S S
LC
LC
LC
S
S
S
S
LC
DINING
ROOM
104
KITCHEN
106
MASTER
BATH
102
MASTER
BED
103
ENTRY
100
BATH 2
108
BED 2
107
LIVING
ROOM
105
BATH 3
101
S3
3
S 3
R
R
R
R
N/R
N/R
N
N
R 3
3CONNECT TO
EXISTING LUMINAIRE
4
N
3
8 2
3a
1
6
CONNECT TO
LIGHTING
CONTROL
SYSTEM
5
1
6
7
n
1
GENERAL NOTES - LIGHTING
DETAIL NOTES - LIGHTING LEGEND - LIGHTING
DECORATIVE PENDANT
1 EXISTING SWITCH TO BE RELOCATED. CONNECT LUMINAIRES IN
BATHROOM AS SHOWN.
REUSE/RECONNECT TO EXISTING LIGHTING CIRCUIT.
EXISTING WALL SCONCE TO BE RELOCATED TO NEW LOCATION
AS INDICATED WITH #3A.
PROVIDE NEW VANITY SCONCE TO MATCH EXISTING.
EXISTING LIGHTING CONTROL KEYPAD TO BE RELOCATED AS
SHOWN. RECONNECT ALL CONTROL CIRCUITS.
EXISTING PENDANT FIXTURE TO BE RELOCATED.
EXISTING WALL MOUNTED LUMINAIRE TO BE REMOVED. RETURN
TO OWNER.
PROVIDE NEW LUMINAIRES TO MATCH EXISTING.
2
3
1. COORDINATE ALL LOCATIONS OF LUMINAIRES AND WALLBOX
CONTROLS WITH INTERIOR DESIGNER AND OWNER PRIOR TO
ROUGH-IN.
2. COORDINATE ALL CONTROLS WITH OWNER, INTERIOR DESIGNER,
AND CONTROLS REPRESENTATIVE.
3. VERIFY ALL VOLTAGES AND WATTAGES OF NEW LUMINAIRES PRIOR
TO ROUGH-IN. ENSURE ADDED LUMINAIRES TO EXISTING 120V
BRANCH LIGHTING CIRCUIT DO NOT EXCEED BREAKER CAPACITY
PER NEC.
4. COORDINATE ALL LUMINAIRE SPECIFICATIONS AND DIMMING
REQUIREMENTS WITH LUTRON REPRESENTATIVE PRIOR TO
PURCHASING TO ENSURE LUMINAIRES ARE COMPATIBLE WITH
EXISTING SYSTEM.
5. VERIFY MOUNTING HEIGHTS AND LOCATIONS OF NEW LUMINAIRES
WITH ARCHITECT / INTERIOR DESIGNER PRIOR TOR ROUGH-IN.
6. ALL LUMINAIRES ARE EXISTING TO REMAIN UNLESS OTHERWISE
SHOWN.
7. REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE
SPECIFICATIONS. COORDINATE WITH INTERIOR DESIGNER FOR
DECORATIVE FIXTURE SPECIFICATIONS.
NOTES:
ALL LIGHTING IS EXISTING TO REMAIN U.O.N.
DASHED FIXTURES INDICATES EXISTING TO BE REMOVE / DEMOLISHED OR
RELOCATED.
N = NEW FIXTURE R = RELOCATED
ACCENT/ART LIGHT
CLOSET LIGHT
4
5
6
7
8
CEILING FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
THREE WAY SWITCH
SINGLE POLE SWITCH
S
S 3 LIGHTING CONTROL PAD, EXISTING U.O.N.
LC
ISSUE DATE
UNIT 7203
FOUR SEASONS
RESORT & RESIDENCES
VAIL, CO
JMM
CHK BY:
SCALE:
SHEET:
JOB #:
DRW BY:
TITLE:
DATE:
COMMENT
AS NOTED
C3S,TNS
UNIT 7203
REMODEL
SEAL & SIGNATURE:
CLIENT:
Tom & Nancy Lacey
Unit 7203
FOUR SEASONS VAIL
1 Vail Road
VAIL, CO 81657
ARCHITECT:
Creative Design Associates
434 BROADWAY, 5TH FLOOR
NEW YORK, NY 10013
t. 212-748-8900
f. 212-748-7950
WESTERN US
4700 E BROMLEY LN, SUITE 105
BRIGHTON, CO 80601
t. 646-747-2171
c. 917-756-0057
dsorenson@ralcompanies.com
INTERIOR DESIGN:
Worth Interiors
30 BENCHMARK ROAD, SUITE 103
AVON, CO 81920
t. 970-949-9794
eddy@worthinteriors.com
ELECTRICAL ENGINEER:
C3S Incorporated
3212 WEST 45TH AVENUE
DENVER, CO 80211
t. 303-480-5144
theresa@c3sengineeringinc.com
15-30
1
FOR PERMIT
09/17/2015
09/17/15
OF 2
LIGHTING PLAN
2E-200
SCALE: 1/4" = 1'-0"
1
LIGHTING PLAN - UNIT 7203
10/07/15