Project: Manor Vail Unit #212 Renovation
595 East Vail Valley Drive, Unit 212A
Vail, CO 81657
Parcel #: 2101-081-05-010
Project # 15.014
Date: REVISED October 10, 2015
Owner: Ellen Lautenberg and Lisa Birer
PO Box 960,
Cliffside Park, NJ 07010
(203) 247-5064 (954)523-3350
e.lautenberg@gmail.com lisa@charlieslocker.com
Contractor: Foster Construction Ltd.
PO Box 1952
Edwards, CO 81632
(970) 926-3202
bfoster@fosterltd.com
Drawings: Foster Sketch Plans
Sheet # Description
A1.0 Cover Page
A1.1 As-Built Floor Plan
A1.2 As-Built Electrical Plan
A1.3 As-Built Reflected Ceiling Plan
A2.0 Renovation Plan
A2.1 Assemblies
ID1.1 Kitchen Cabinet Plans and Elevations
ID 1.2 Kitchen Perspective Views
ID 1.3 Bath #212 & Bath 213 Plans & Elevations
ID 1.4 Bedroom #213 & Bath 214 Plans & Elevations
Type of Construction: VA
Occupancy Classification: R-2
Proposed Area: No Change to existing
Allowable Height per tale 503: 4 stories (Existing = 2)
The existing building has an approved automatic fire sprinkler system installed.
Fire resistance rating per table 601:
Primary Structural Frame: 1 hour
Exterior Bearing Walls 1 hour
Exterior Non-bearing walls: 0 hour
Interior Bearing Partitions: 1 hour
Interior Non-bearing Partitions: 0 hour
Floors: 1 hour
Roof: 1 hour
Fire resistance rating of wall between dwelling units and sleeping units shall be 1 hour per IBC 708.3
*Per footnote “d” in table 601 of the 2012 IBC, protection of the primary structural frame may be reduced by 1
hour if the building is protected with an automatic sprinkler system.
**Per table 602 of the 2012 IBC, the fire resistance of nonbearing exterior walls is 0 hours if the separation
distance is > 30’
DETAIL – RECESSED FIXTURE ENCLOSURE
scale 1-1/2” = 1’-0”
Per 714.4.1.2 Any recessed fixtures that are installed in fire-resistance-rated horizontal assemblies shall not reduce the level of required fire
resistance.
Install 5/8” type X drywall to create a five (5) sided cavity in which to place the recessed fixture, fire tape the drywall joints, install the recessed
fixture, apply a liberal bead of Hilti Fire Stop sealant CP 606 to the perimeter edge of the drywall of the cavity drywall and then install the ceiling
drywall. Inspect the sealant joint from the attic to insure a complete seal of the joint to the ceiling drywall apply addition sealant at the perimeter
if needed.