HomeMy WebLinkAboutSolar Calculations.pdf Page 1 of 4 10/13/2015 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233/info@activeenergies.com) Site: Johnson Residence Sunlight North Condominiums 2475 Garmisch Drive #5 Vail, CO 81657 System Layout: Single Panel = 5.38ft tall X 3.28ft wide System Size = 13.52ft tall X 16.18ft wide (including mounting equipment) Panel Arrangement: 2 columns of 5 panels oriented in the landscape position, mounted flush on the southeast facing roof Equipment: Panels: 10 LG315N1C-G4 @ 315 watts Inverter: 10 SolarEdge P320 optimizers + 1 SolarEdge SE3000A-US inverter Mounting Equipment: Unirac racking system with Easy Feet Monitoring: SolarEdge Remote Energy Monitoring System Holy Cross electric meter located on in the southwest side of the condo complex. The PV disconnect and inverter to be located on the northwest side (back) of the individual unit. Meter placard required for Holy Cross. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer PV disconnect & inverter Holy Cross meter Page 2 of 4 10/13/2015 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Calculations 3.15kW System Size (STC)  10 LG315N1C-G3 solar modules @ 315watts  10 SolarEdge P320 Optimizers  1 SolarEdge SE3000A-US inverter (1 string of 10 modules/optimizers)  Fixed array tilt angle: 18.43º  Array azimuth: 105º (where 180º is south)  Estimated annual power production: 4,068kWh Maximum PV System Voltage: 690.7 Voc = 40.6V/module 40.6V x 1 module = 40.6V Temperature correction factor 690.7(A) STC = 25°C, Temperature Coefficient (Voc) = -0.28 %/°C (-40°C - 25°C) = 65°C 40.6V + (-65°C x (-0.28%/°C x 40.6V) x 1 module) = 48V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 10.02A 10.02A x 1.25 = 12.5A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) 3,150w / 350v = 9A per 10 string SE3000A-US inverter limit 9.5A combined string Inverter Output Circuit Current: 690.8 (A)(3) 12.5A @ 240V John Wiles, “Photovoltaic Power Systems and the National Electrical Code: Suggested Practices”, 2005, pp. E1-E25. pdf version online at: http://www.nmsu.edu/%7Etdi/Photovoltaics/Codes- Stds/PVnecSugPract.html Page 3 of 4 10/13/2015 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Conductor Sizing Pass Thru Box from Optimizers to Inverter (per combined string): SE3000A-US inverter limit 12.5A combined string 9.5A x 1.25 = 11.9A #10 THWN-2 Table 310.16 40A (90ºC column, see note 240.4(D)) Conduit fill adjustment Table 310.15 (B)(3)(a) No conduit fill adjustment Temperature correction factor Table 310.15 (B)(2)(b) 40A x .77 = 30.8A Inverter to Disconnect to Service Panel: Nameplate maximum continuous output current: 12.5A @ 240V 12.5A x 125% = 15.6A 210.19 (A)(1) #10 THWN-2 Table 310.16 30A (75ºC column) No temperature correction factor No conduit fill adjustment Overcurrent Protection Device 20A two pole breaker Per Manufacturer Specification Conductors may be oversized for voltage drop