HomeMy WebLinkAboutD110.pdfEXIT
KEYNOTES
# - KEYNOTE SYMBOL
GENERAL NOTES
LEGEND
EXISTING CONDITION TO REMAIN
REPAIR AS REQUIRED TO MAINTAIN
REQUIRED RATINGS AND ACCEPT
FINAL TENANT FINISHES
ITEM TO BE DEMOLISHED
DEMO PLAN - GENERAL
DEMO PLAN - HANDLING
DEMO PLAN - SEQUENCING & EXECUTION
UPON COMPLETION OF DEMOLITION, CONTRACTOR SHALL VERIFY EXISTING COLUMN LOCATIONS &
OVERHEAD STRUCTURE & PROVIDE ARCHITECT W/ PHOTOGRAPHS & SKETCHES AS NEEDED FOR TENANT'S
STRUCTURAL DESIGN TO BE VERIFIED & CORRECTED IF NECESSARY - CRITICAL
A B
C D
2
1
V.I.F.
7'-6"
V.I.F.
21'-4"
V.I.F.
22'-4"
V.I.F.
18'-8"
V.I.F.
21'-6"
V.I.F.
22'-8 1/2"
V.I.F.
3'-10"
V.I.F.
7'-4"
V.I.F.
6'-0"
V.I.F.
7'-4 3/4"
V.I.F.
3'-10 3/4"
V.I.F.
20'-11 3/4"
V.I.F.
20'-7 3/4"
V.I.F.
21'-9 1/4"
V.I.F.
69'-1"
1 9 10 11 12 13
2
2
2
2
2 2
2 2 2
2
2
4
2
4
4
3
3
3
17
(E) STAIR AND RAILINGS TO BE
DEMOLISHED IN IT'S ENTIRETY. G.C TO
PROTECT-IN-PLACE ANY SLAB
REINFORCEMENT, AND/OR WATER
PROOFING. PREP AREA FOR NEW
STAIR CONSTRUCTION.
(E) ENTRANCE DOORS
TO REMAIN.
(E) STOREFRONT TO
REMAIN, TYP.
PATCH & REPAIR SLAB
FOR SMOOTH SURFACE.
PREP FOR NEW CLEAR
COAT SEAL.
V.I.F.
70'-6"
NOTE:
-G.C TO PATCH AND REPAIR ANY DAMAGE TO (E) FIRE SEPARATION,
SOUND ATTENUATION, OR FIRE
PROTECTION CAUSED BY DEMOLITION OR NEW CONSTRUCTION.
-G.C. TO COORDINATE ANY FIXTURES TO BE
STORED AND PRESERVED OR DEBRANDED
AND DEMOLISHED WITH LULULEMON STORE MANAGER.
V.I.F.
15'-8"
EXTERIOR
EXTERIOR
ADJACENT
TENANT
(E) COMMON
RESTROOM
(E) COMMON
RESTROOM
CORRIDOR
(E)SOFFIT TO
REMAIN
ASBESTOS CEILING FINISH TO
BE REMOVED BY HAZ. MAT.
PROFESSIONAL PRIOR TO
DEMOLITION AND
CONSTRUCTION OF THE
SPACE.
(E) SOFFIT AND HVAC
SYSTEM TO REMAIN.
REMOVE (E)
AIR TRANSFER
GRILL. PREP FOR
REUSE IF IN GOOD
WORKING ORDER.
G.C. TO GRIND (E)
CONC. FLOOR TO
ENSURE SMOOTH
EVEN FLOORING.
REZA A. HADAEGH
402807
S
T
A
T
E
O
F
C
O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I
T
E
C
T
Scale:
Job Number:
Drawing:
LULULEMON ATHLETICA
CONSTRUCTION STANDARDS
Checked By:
Drawn By:
Date:
ISSUED FOR DD-LLL xx/xx/xx
ISSUED FOR DD-LLD
ISSUED FOR CD-LLL 07/31/14
ISSUED FOR CD-LLD 08/14/14
ISSUED FOR PERMIT 08/15/14
ISSUED FOR BID xx/xx/xx
ISSUED FOR SD NA
07/03/14
19780
08/15/14
D110
DEMO PLAN & RCP
NA
BAB
193 GORE CREEK DRIVE
Vail, CO 81657 SCALE: 3/8" = 1'-0"
1
DEMOLITION & RCP PLAN
TRUE
NORTH
1 REMOVE EXISTING FINISH FLOOR IN ITS ENTIRETY TO THE SUBFLOOR. PATCH &
REPAIR REMAINING SUBFLOOR AS REQUIRED TO RECEIVE NEW FINISHES.
2 REMOVE EXISTING PARTITION IN ITS ENTIRETY. PATCH AND REPAIR ALL
REMAINING ADJACENT PARTITIONS, FLOOR AND CEILING AS REQUIRED TO
PROVIDE LIKE NEW CONDITION. COORDINATE WITH PLAN.
3 PATCH AND REPAIR EXISTING WALL TO PROVIDE LIKE NEW CONDITION.
4 REMOVE EXISTING DOOR AND FRAME IN ITS ENTIRETY.
5 REMOVE EXISTING PLUMBING FIXTURES. CUT AND CAP ALL ABANDONED
FIXTURES. COORDINATE WITH PLAN.
6 REMOVE EXISTING TOILET ROOM ACCESSORY FIXTURES. PATCH AND REPAIR
EXISTING WALLS TO PROVIDE LIKE NEW CONDITION. COORDINATE WITH PLAN.
7 REMOVE ALL EXISTING GWB OR ACT (CIRCLE ONE) CEILINGS, SOFFITS AND
CONNECTIONS TO STRUCTURE ABOVE.
8 REMOVE ALL EXISTING CEILING SYSTEMS, LIGHTING, HVAC REGISTERS,
DUCTWORK, ELECTRICAL CONDUITS U.N.O. TO REMAIN ON THIS SHEET OR THE
ARCHITECTURAL RCP OR SHOWN IN THE MEP DRAWINGS.
9 PROPERLY REMOVE ANY AND ALL ABANDONED ELECTRICAL WIRING FOR
TRACK LIGHT FIXTURES, CONDUITS, OUTLETS, ETC. EXPOSED OR CONCEALED IN
THE CEILING AND OR PARTITIONS. SEE SPECIFICATIONS FOR DISPOSAL
METHODS.
10 REMOVE EXISTING LIFE SAFETY AND EXIT SIGNAGE.
11 EXISTING FIRE SPRINKLERS SHALL BE RELOCATED IN ALL 3 DIMENSIONS AS
REQUIRED, U.N.O.
12 REMOVE AND OR RELOCATE EXISTING MECHANICAL EQUIPMENT PER MEP
DRAWINGS
13 REMOVE ALL FLOOR AND WALL MILLWORK FIXTURES FROM PREVIOUS TENANT
U.N.O.
14 REMOVE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE NEW PLUMBING
BELOW SLAB.
15 EXISTING COLUMN TO REMAIN. G.C. TO PATCH AND REPAIR FIRE PROOFING AS
REQUIRED.
16 REMOVE EXISTING STOREFRONT IN ITS ENTIRETY . DO NOT DAMAGE BASE
BUILDING UTILITIES, STRUCTURE OR MALL SOFFIT AND NEUTRAL PIERS. PATCH
AND REPAIR AS REQUIRED TO MATCH EXISTING.
17 REMOVE EXISTING CONCRETE SLAB AS REQUIRED TO RECESS SENSORMATIC
EQUIPMENT AT NEW STOREFRONT DOOR, COORDINATE WITH LANDLORD FOR
REQUIREMENTS/ RESTRICTIONS
A SUBMIT FOR APPROVAL SELECTIVE DEMOLITION SCHEDULE, INCLUDING SCHEDULE AND METHODS FOR CAPPING AND CONTINUING UTILITY SERVICE.
B ALL WORK SHALL COMPLY WITH THE RULES AND REGULATIONS OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL OTHER LOCAL, STATE AND FEDERAL AGENCIES AND AUTHORITIES HAVING JURISDICTION.
C OBTAIN AND PAY FOR ALL PERMITS REQUIRED TO PERFORM THE DEMOLITION WORK AS REQUIRED BY ALL AGENCIES AND AUTHORITIES HAVING JURISDICTION.
D DEMOLITION CONTRACTOR SHALL COORDINATE AND BE RESPONSIBLE FOR ALL CITY REQUIREMENTS FOR PROTECTION OF PERSONS, PROPERTY, TRAFFIC CONTROL, BARRICADES, ETC. FOR THE DURATION OF THE DEMOLITION CONTRACT.
E COORDINATE WITH GENERAL CONTRACTOR A SCHEDULE FOR DEMOLITION OF SPECIFIC ITEMS TO CONFORM WITH SCHEDULING FOR OTHER TRADES REQUIRED TO COMPLETE OR PERFORM A DIRECTLY RELATED PORTION OF THE WORK.
A WHEN THE NATURE OF DEMOLITION WORK REQUIRES THEIR USE, ERECT AND MAINTAIN DUST CHUTES FOR THE DISPOSAL OF MATERIALS, RUBBISH AND DEBRIS.
B REMOVE SALVAGE AND DEBRIS FROM THE SITE AS IT ACCUMULATES. DO NOT STORE, SELL, BURN OR OTHERWISE DISPOSE OF DEBRIS ON THE SITE. REMOVE ALL MATERIALS IN SUCH MANNER AS TO PREVENT SPILLAGE. KEEP ALL PAVEMENT AND AREAS ADJACENT TO AND
LEADING FROM THE SITE, CLEAN AND FREE OF MUD, DIRT, AND DEBRIS AT ALL TIMES. ALL MATERIAL SHALL BE DISPOSED OF LEGALLY.
C ERECT AND MAINTAIN TEMPORARY BRACING, SHORING, LIGHTS, BARRICADES, WARNING SIGNS, AND GUARDS NECESSARY TO PROTECT BUILDING OCCUPANTS, AND ADJOINING TENANTS FROM INJURY, AND/OR DAMAGE, ALL IN ACCORDANCE WITH APPLICABLE RULES AND
REGULATIONS.
D DO NOT DAMAGE BUILDING ELEMENTS AND IMPROVEMENTS INDICATED TO REMAIN. ITEMS OF SALVAGE VALUE WHICH ARE NOT INCLUDED ON SCHEDULE OF SALVAGE ITEMS TO BE RETURNED TO OWNER SHALL BE REVIEWED WITH OWNER AS TO WHETHER THEY CAN BE
REMOVED FROM THE PREMISES. STORAGE OR SALE OF ITEMS AT PROJECT SITE IS PROHIBITED. DEMOLISHED MATERIAL SHALL BE COMPLETELY REMOVED FROM THE SITE AND DISPOSED OF USING LEGAL METHODS.
E DO NOT CLOSE OR OBSTRUCT THE MEANS OF EGRESS, CORRIDORS, OR OTHER SPACES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND THE OCCUPIED AUTHORITIES HAVING JURISDICTION. DO NOT INTERRUPT UTILITIES WITHOUT THE WRITTEN PERMISSION OF THE
OWNER OR AUTHORITIES HAVING JURISDICTION. IF NECESSARY, PROVIDE TEMPORARY UTILITIES.
F CEASE OPERATIONS IF PUBLIC SAFETY OR REMAINING STRUCTURES ARE ENDANGERED. PERFORM TEMPORARY CORRECTIVE MEASURES UNTIL OPERATIONS CAN BE CONTINUED PROPERLY.
A BY CAREFUL STUDY OF THE CONTRACT DOCUMENTS, DETERMINE THE LOCATION AND EXTENT OF SELECTIVE DEMOLITION TO BE PERFORMED.
B VISIT THE SITE AND VERIFY THE EXTENT AND LOCATION OF SELECTIVE DEMOLITION REQUIRED PRIOR TO STARTING THE WORK. 1) CAREFULLY IDENTIFY LIMITS OF SELECTIVE DEMOLITION. 2) MARK INTERFACE SURFACES AS REQUIRED TO ENABLE WORKMEN TO ALSO
IDENTIFY ITEMS TO BE REMOVED, ITEMS TO BE LEFT IN PLACE INTACT, ITEMS TO BE SALVAGED, AND ITEMS TO BE REMOVED AND SORTED FOR RECYCLING.
C PREPARE AND FOLLOW ORGANIZED PLAN FOR DEMOLITION AND REMOVAL OF ITEMS. 1) SHUT OFF, CAP, AND OTHERWISE PROTECT EXISTING UTILITY LINES IN ACCORDANCE WITH THE REQUIREMENTS OF THE PUBLIC AGENCY OR UTILITY HAVING JURISDICTION. 2) COMPLETELY
REMOVE ITEMS SCHEDULED TO BE SO DEMOLISHED AND REMOVED, LEAVING SURFACES CLEAN, SOLID, AND READY TO RECEIVE NEW MATERIALS SPECIFIED ELSEWHERE. IN ALL ACTIVITIES, COMPLY WITH PERTINENT REGULATIONS, GOVERNMENTAL AGENCIES HAVING
JURISDICTION.
D USE MEANS NECESSARY TO PREVENT DUST BECOMING A NUISANCE TO OTHER TENANTS OF THE BUILDING, THE PUBLIC, NEIGHBORING BUILDINGS, AND TO OTHER WORK BEING PERFORMED.
E EXECUTE DEMOLITION WORK TO ENSURE SAFETY OF PERSONS AND ADJACENT PROPERTY AGAINST DAMAGE BY FALLING DEBRIS.
F IN THE EVENT OF THE DEMOLITION OF ITEMS NOT SCHEDULED TO BE DEMOLISHED, PROMPTLY REPLACE SUCH ITEMS TO THE APPROVAL OF THE ARCHITECT AND/OR CONSTRUCTION MANAGER AT NO ADDITIONAL COST TO THE OWNER.
G WHERE EXISTING CONSTRUCTION TO REMAIN IS AFFECTED BY DEMOLITION OR INSTALLATION OF NEW WORK, PATCH, REPAIR OR REPLACE THE WORK AT SURFACES WHICH HAVE BEEN DAMAGED TO MATCH EXISTING (T.M.E.) ADJACENT CONSTRUCTION.
H FINISH NEW AND EXISTING SURFACES AS SCHEDULED. CLEAN EXISTING SURFACES OF DIRT, GREASE AND LOOSE PAINT BEFORE REFINISHING.
J COORDINATE THE REMOVAL, RELOCATION, REPLACEMENT, RE-USE, SHUT-OFF, STUB-OFF, CAPPING-OFF OR UPGRADING OF ALL EXISTING SPRINKLER, HVAC, FIRE ALARM, SECURITY AND ELECTRICAL SYSTEMS, EQUIPMENT, AND APPURTENANCES - INCLUDING, BUT NOT
LIMITED TO, UTILITY LINES, DUCTS, CONNECTIONS, PANELS, VENTS, FANS, PIPING, DEVICES, CONTROLS, OUTLETS, AND CONDUIT DURING CONSTRUCTION AS REQUIRED, AS SCHEDULED, OR AS SPECIFIED IN ACCORDANCE WITH ALL LOCAL, MUNICIPAL AND STATE CODES.
NO. DATE
DESCRIPTION
There are no exterior facade
changes approved in
conjunction with this permit.
10/08/14