Loading...
HomeMy WebLinkAboutA0-01 - ADA COMPLIANCE.pdf60" min. 18" x 48" min 48" min. Y X 54 min 42" min 42" min 24" min. 24" min. 54" min. 42" min. 48" min 24 min. 42" min. 48" min. 48" min. 1/4" 1/4" to 1/2" 6" max. 36" min 12" min 19" min 33" - 36" 12" 42" min. 54" min. 9" min. 27" min. 29" min. 34" min. 6" max. min. 8" 17" min. depth 40" min. 17" - 19" 9" min. 27" min. 6" max 8" min. 36" max. 30" min. 48" min. max. 19" 17" min. 30" min 48" min 30" min 48" min 48" min. 30" min. 17" - 19" 24" max 1.5" 1.25" - 1.5" 1.5" 1.25" - 1.5" 60 min. 60 min 36" min. 12" min. 36" min. 12" min. 60" min. 60" min. 12" min 12"min 36" min 12" min 12" min 34" - 38" 34" - 38" 36" min 36" min 36" min 12" min 54" max* 48" max* 27" or 48" max 30" min 20" max 24 max 10" 30 min 48" min min 30" 6" min 48" max 18" 18" 42" min. 60" min. 56" min. 17" - 19" < 27" 20" max 24 max 80" min 4" max. higher then 27" any amount clear width 27" or below 27" max. greater then 12" greater then 12" 27" max. 27" 80" 27" max. 12" max. 12" max. 39" - 41" 39" - 41" 18" min. 24" preferred PULL SIDE PUSH SIDE PULL SIDE PUSH SIDE PULL SIDE PUSH SIDE Y Y max 1 2 X Y 96" min. for VANS 10 1 (ada) - 4.4 Protruding Objects. 4.4.1 General. Objects projecting from walls (for example, telephones) with their leading edges between 27" and 80"(685mm and 2030mm) above the finish floor shall protrude no more than 4" (100 mm) into walks, halls, corridors, passageways, or aisles (see Fig. 8(a)). Objects mounted with their leading edges at or below 27" (685mm) above the finish floor may protrude any amount (see Fig. 8(a) and (b)). Free-standing objects mounted on posts or pylons may overhang 12" (305mm) maximum from 27" to 80" (685mm to 2030mm) above the ground or finished floor (see Fig. 8(c) and (d). Free-standing objects mounted on posts or pylons may overhang 12" (305mm) maximum from 27" to 80" (685mm to 2030mm) above the ground. (ADA) - 4.2.3 Wheelchair Turning Space. The space required for a wheelchair to make a 180-degree turn is a clear space of 60" (1525mm) diameter (see Fig.3(a)) or a T-shaped space (see Fig. 3(b)). (ADA) - 4.7.11 Islands. Any raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and a level area at least 48" (1220mm) long between the curb ramps in the part of the island intersected by the crossings. (ADA) - 4.7.7 Detectable Warnings. A curb ramp shall have a detectable warning complying with 4.29.2. The detectable warning shall extend the full width and depth of the curb ramp. X (ADA) - 4.18 Urinals. 4.18.1 General. Accessible urinals shall comply with 4.18. 4.18.2 Height. Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17" (430mm) above the finish floor. 4.18.3 Clear Floor Space. A clear floor space 30" x 48" (760mm x 1220mm) shall be provided in front of urinals to allow forward approach. This clear space shall adjoin or overlap an accessible route and shall comply with 4.2.4. Urinal shields that do not extend beyond the front edge of the urinal rim may be provided with 29" (735mm) clearance between them. (ADA) - 4.22 Toilet Rooms. 4.22.3 Clear Floor Space. The accessible fixtures and controls required in 4.22.4, 4.22.5, 4.22.6, and 4.22.7 shall be on an accessible route. An unobstructed turning space complying with 4.2.3 shall be provided within an accessible toilet room. The clear floor space at fixtures and controls, the accessible route, and the turning space may overlap. ACCESSIBLE ROUTE LANDING LEVEL LANDING LEVEL SLOPE (INCHES) (FEET ) 10 1 36" min typ ELEVATION wall curb min 2" curb SECTION vertical ground rail below 27" or width any plans see below max elevation plan plans elevation TOILET T.P. LEVER VALVE PROTECTED PIPING clearance toe MIRROR space floor clear (a) 60" Diameter Space (b) T-Shaped Space for 180 Degree Turns plan elevation cane range elevation PROTRUDING OBJECTS FIG. 8 36" min 60" min 21' - 0" min 96" min HORIZONTAL PROJECTION OR RUN RISE WALK STREET MAX RISE MAX. HORIZ. PROJECTION 20'- 0" min 5'- 0" min X Y CL (a) back wall (b) side wall plan (ADA) - 4.19.6 Mirrors. Mirrors shall be mounted with bottom edge of the reflecting surface no higher than 40" (1015mm) above the finish floor (see Fig. 31). Reference Site Plan (sheet A1.00) for Type A (Accessible Unit) locations. FIG. 9 (ADA) FIG. 502.2 & 502.3 (ANSI) DIMENSION OF PARKING SPACES FIG. 10 (ADA) FIG. 503.3 (ANSI) ACCESS AISLE AT PASSENGER LOADING ZONES ADJOINING SLOPE SHALL NOT EXCEED 1: 20 SLOPE = Y : X WHERE X IS A LEVEL PLANE FIG. 11 (ADA) MEASUREMENT OF CURB RAMP SLOPE 1:12 TO <1:16 30 30 1:16 TO <1:20 30 40 FIG. 16 (ADA) COMPONENTS OF A SINGLE RAMP RUN AND SAMPLE RAMP DIMENSIONS If X is less than 48" then the slope of the flared side shall not exceed 1:12 flared side (a) flared side planting or other non-walking surface (b) returned curb FIG. 13 (ADA) BUILT - UP CURB RAMP FIG. 12 (ADA) SIDES OF CURB RAMPS rolling with extended platform FIG. 17 (ADA) EXAMPLES OF EDGE PROTECTION AND HANDRAIL EXTENSIONS FIG. 39 (a) (ADA) HANDRAIL opt. post and base (a) Side Reach Possible (b) Forward Reach Required * Height to heighest operable parts which are essential to basic operation of telephone. FIG. 44 (ADA) MOUNTING HEIGHTS AND CLEARANCES FOR TELEPHONES (a) Front Approach - Swinging Doors NOTE : X = 12" if door has both closer and latch NOTE : Y = 48" min. if door has both closer and latch NOTE : X = 36" min. If Y = 60" X = 42" min. If Y = 54" (b) Hinge Side Approach - Swinging Doors NOTE : Y = 54" min. if door has closer. NOTE : Y = 48" min. if door has closer. (c) Latch Side Approach - Swinging Doors FIG. 25 (ADA) MANEUVERING CLEARANCES AT DOORS NOTE : All doors in alcoves shall comply with the clearances for front approaches (d) Front Approach - Sliding Doors and Folding Doors (e) Slide Side Approach - Sliding Doors and Folding Doors (f) Latch Side Approach - Sliding Doors and Folding Doors FIG. 26 (ADA) TWO HINGED DOORS IN SERIES FIG. 7 (c & d) (ADA) CHANGES IN LEVEL FIG. 29 (ADA) GRAB BARS AT WATER CLOSETS (ANSI A117.1-2003 FIG. 604.5.1 & 604.5.2) knee clearance FIG. 31 (ADA) LAVATORIES CLEARANCE FIG. 32 (ADA) CLEAR FLOOR SPACE AT LAVATORIES clear floor space FIG. 28 (ADA) CLEAR FLOOR SPACE AT WATER CLOSETS equipment permitted in shaded area (a) Spout Height and Knee Clearance (b) Clear Floor Space FIG. 39 (e) (ADA) GRAB BAR (c) Free - Standing Fountain or Cooler (d) Built - in Fountain or Cooler FIG. 27 (ADA) DRINKING FOUNTAINS AND WATER COOLERS not to exceed fountain depth FIG. 3 (ADA) WHEELCHAIR TURNING SPACE Fig. 8 (a) Walking Parallel to a Wall Fig. 8 (b) Walking Perpendicular to a Wall Fig. 8 (c) Free--Standing Overhanging Object protect shaded area from cross - traffic Fig. 8(c-1) OverHead Hazards Fig. 8(d) Objects Mounted on posts or pylons cane hits post or pylon before person hits object cane range this overhang can be greater than 12" because no one can approach the object from this direction Codes & Regulations Referenced: ADA (American Disabilities Act 07-01-99 Edition) FHA (Fair Housing Act 04-01-99 Edition) FHADM (FHA Design Manual Revised April 1998 Edition) ANSI (ICC/ANSI A117.1-2003) Note: Only a portion of applicable codes & regulations shown, see each applicable code manual for a complete list of all codes 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 182 WEST MEADOW DRIVE VAIL, CO 81657 A0.01 ADA COMPLIANCE PIETRINI RESIDENCE Project Number - 1428 08/18/14 DRB SUBMITTAL DRB APPROVED 8/20/2014 12:00:00 AM