HomeMy WebLinkAboutA0-02 - ADA COMPLIANCE.pdf60" min.18"x48" min48" min.YX54 min42" min42" min24" min.24" min.54" min.42" min.48" min24 min.42" min.48" min.48" min.1/4"1/4" to 1/2"6" max.36" min12" min19" min33" - 36"12"42" min.54" min.9" min.27" min.29" min.34" min.6" max.min. 8"17" min. depth40" min.17" - 19"9" min.27" min.6" max8" min.36" max.30" min.48" min.max. 19"17" min.30" min48" min30" min48" min48" min.30" min.17" - 19"24" max1.5"1.25" - 1.5"1.5"1.25" - 1.5"60 min.60 min36" min.12" min.36" min.12" min.60" min.60" min.12" min12"min36" min12" min12" min34" - 38"34" - 38"36" min36" min36" min12" min54" max*48" max*27" or48" max 30" min20" max24 max10"30 min48" minmin 30" 6" min48" max18"18"42" min.60" min.56" min.17" - 19"< 27"20" max24 max80" min4" max.higher then 27"any amountclear width27" or below27" max.greater then 12" greater then 12"27" max.27"80"27" max.12" max.12" max.39" - 41"39" - 41" 18" min.24" preferredPULL SIDEPUSH SIDEPULL SIDEPUSH SIDEPULL SIDEPUSH SIDEYYmax12XY96" min. for VANS101(ada) - 4.4 Protruding Objects.4.4.1 General.Objects projecting from walls (forexample, telephones) with their leadingedges between 27" and 80"(685mm and2030mm) above the finish floor shallprotrude no more than 4" (100 mm) intowalks, halls, corridors, passageways, oraisles (see Fig. 8(a)). Objects mountedwith their leading edges at or below 27"(685mm) above the finish floor mayprotrude any amount (see Fig. 8(a) and(b)). Free-standing objects mounted onposts or pylons may overhang 12"(305mm) maximum from 27" to 80"(685mm to 2030mm) above the ground orfinished floor (see Fig. 8(c) and (d).Free-standing objects mounted on postsor pylons may overhang 12" (305mm)maximum from 27" to 80" (685mm to2030mm) above the ground.(ADA) - 4.2.3 Wheelchair Turning Space.The space required for a wheelchair tomake a 180-degree turn is a clear spaceof 60" (1525mm) diameter (see Fig.3(a)) ora T-shaped space (see Fig. 3(b)).(ADA) - 4.7.11 Islands.Any raised islands in crossings shall be cut throughlevel with the street or have curb ramps at both sidesand a level area at least 48" (1220mm) long betweenthe curb ramps in the part of the island intersected bythe crossings.(ADA) - 4.7.7 Detectable Warnings.A curb ramp shall have a detectable warning complyingwith 4.29.2. The detectable warning shall extend the fullwidth and depth of the curb ramp.X(ADA) - 4.18 Urinals.4.18.1 General.Accessible urinals shall comply with 4.18.4.18.2 Height.Urinals shall be stall-typeor wall-hung with an elongated rim at amaximum of 17" (430mm) above the finishfloor.4.18.3 Clear Floor Space.A clear floor space 30" x 48" (760mm x1220mm) shall be provided in front ofurinals to allow forward approach. Thisclear space shall adjoin or overlap anaccessible route and shall comply with4.2.4. Urinal shields that do not extendbeyond the front edge of the urinal rimmay be provided with 29" (735mm)clearance between them.(ADA) - 4.22 Toilet Rooms.4.22.3 Clear Floor Space.The accessible fixtures and controlsrequired in 4.22.4, 4.22.5, 4.22.6, and4.22.7 shall be on an accessible route.An unobstructed turning space complyingwith 4.2.3 shall be provided within anaccessible toilet room. The clear floorspace at fixtures and controls, theaccessible route, and the turningspace may overlap.ACCESSIBLE ROUTELANDINGLEVELLANDINGLEVELSLOPE (INCHES) (FEET )10136" mintypELEVATIONwallcurbmin2" curbSECTIONvertical ground railbelow27" orwidthanyplansseebelowmaxelevation planplanselevationTOILETT.P.LEVER VALVEPROTECTED PIPINGclearancetoeMIRRORspacefloorclear(a) 60" Diameter Space (b) T-Shaped Space for 180 Degree Turnsplan elevationcane rangeelevationPROTRUDING OBJECTSFIG. 836" min60" min21' - 0" min96" minHORIZONTAL PROJECTION OR RUNRISEWALKSTREETMAX RISE MAX. HORIZ. PROJECTION20'- 0" min5'- 0" minXYCL (a) back wall (b) side wallplan(ADA) - 4.19.6 Mirrors.Mirrors shall be mounted with bottom edgeof the reflecting surface no higher than 40"(1015mm) above the finish floor (see Fig. 31).Reference Site Plan(sheet A1.00) for TypeA (Accessible Unit) locations.FIG. 9 (ADA)FIG. 502.2 & 502.3 (ANSI)DIMENSION OF PARKING SPACESFIG. 10 (ADA)FIG. 503.3 (ANSI) ACCESS AISLE AT PASSENGERLOADING ZONESADJOINING SLOPE SHALLNOT EXCEED 1: 20SLOPE = Y : XWHERE X IS ALEVEL PLANEFIG. 11 (ADA)MEASUREMENT OF CURB RAMP SLOPE1:12 TO <1:16 3030 1:16 TO <1:20 30 40FIG. 16 (ADA)COMPONENTS OF A SINGLE RAMP RUNAND SAMPLE RAMP DIMENSIONSIf X is less than 48"then the slope ofthe flared sideshall not exceed1:12flared side(a)flaredsideplanting orothernon-walkingsurface(b)returnedcurbFIG. 13 (ADA)BUILT - UP CURB RAMPFIG. 12 (ADA)SIDES OF CURB RAMPSrolling withextended platformFIG. 17 (ADA)EXAMPLES OF EDGE PROTECTIONAND HANDRAIL EXTENSIONSFIG. 39 (a) (ADA)HANDRAILopt.postandbase(a) Side Reach Possible(b) Forward Reach Required* Height to heighestoperable parts which areessential to basicoperation of telephone.FIG. 44 (ADA)MOUNTING HEIGHTS AND CLEARANCESFOR TELEPHONES(a)Front Approach - SwingingDoorsNOTE : X = 12" ifdoor has bothcloser and latchNOTE : Y = 48" min.if door has bothcloser and latchNOTE : X = 36" min. If Y = 60" X = 42" min. If Y = 54"(b)Hinge Side Approach - SwingingDoorsNOTE : Y = 54" min. if door has closer.NOTE : Y = 48" min. if door has closer.(c)Latch Side Approach - SwingingDoorsFIG. 25 (ADA)MANEUVERING CLEARANCES AT DOORSNOTE : All doors in alcoves shall comply withthe clearances for front approaches(d)Front Approach - SlidingDoors and Folding Doors(e)Slide Side Approach - SlidingDoors and Folding Doors(f)Latch Side Approach - SlidingDoors and Folding DoorsFIG. 26 (ADA)TWO HINGED DOORS IN SERIESFIG. 7 (c & d)(ADA) CHANGES INLEVELFIG. 29 (ADA)GRAB BARS AT WATER CLOSETS(ANSI A117.1-2003 FIG. 604.5.1 &604.5.2)knee clearanceFIG. 31 (ADA)LAVATORIES CLEARANCEFIG. 32 (ADA)CLEAR FLOOR SPACE AT LAVATORIESclear floor spaceFIG. 28 (ADA)CLEAR FLOOR SPACE AT WATER CLOSETSequipmentpermitted inshaded area(a)Spout Heightand KneeClearance(b)Clear FloorSpaceFIG. 39 (e) (ADA)GRAB BAR(c)Free - StandingFountain orCooler(d)Built - in Fountainor CoolerFIG. 27 (ADA)DRINKING FOUNTAINS AND WATER COOLERSnot toexceedfountaindepthFIG. 3 (ADA)WHEELCHAIR TURNING SPACEFig. 8 (a)Walking Parallel to a WallFig. 8 (b)Walking Perpendicular to aWallFig. 8 (c)Free--Standing OverhangingObjectprotectshaded areafrom cross -trafficFig. 8(c-1)OverHeadHazardsFig. 8(d)Objects Mounted on posts orpylonscane hitspost orpylonbeforeperson hitsobjectcane rangethis overhang can begreater than 12" becauseno one can approach theobject from this directionCodes & Regulations Referenced:ADA (American Disabilities Act 07-01-99 Edition)FHA (Fair Housing Act 04-01-99 Edition)FHADM (FHA Design Manual Revised April 1998 Edition)ANSI (ICC/ANSI A117.1-2003)Note: Only a portion of applicable codes & regulationsshown, see each applicable code manual for acomplete list of all codes1650 Fallridge Road, Suite C-1Vail, Colorado 81657f.(970) 476-4901 p.(970)476-6342182 WEST MEADOW DRIVEVAIL, CO 81657A0.02ADACOMPLIANCEPIETRINI RESIDENCEProject Number - 142809/05/14PERMIT SET