HomeMy WebLinkAboutA0-09 - ASSEMBLIES.pdfGENERAL ASSEMBLY AND FINISH SYSTEMSNote: Reference structural drawings and specifications for all fasteners within all building assemblies including but notlimited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with anydiscrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformancewith product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product.Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern overarchitectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall locationdimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior toinstallation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The followingassembly narratives are general.WALL SYSTEMS:RATED ASSEMBLIES (@ MAIN & UPPER LEVELS):F1-WWOOD PLANK ON GYPCRETE(1-Hr. Fire Rated Assembly - U.L. L521)Carpet and pad, installed per manufacturer's specifications, over 1 1/2" thick Gypcrete 2000 underlayment over1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufacturedfloor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" FIRECODE "C" gypsumboard ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. Fill void(between floors) with glass fiber mineral wool insulation installed between the floor trusses and supported bythe resilient channels.F1-CCARPET ON GYPCRETE(1-Hr. Fire Rated Assembly - U.L. L521)Carpet and pad, installed per manufacturer's specifications, over 1 1/2" thick Gypcrete 2000 underlayment over1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufacturedfloor trusses at 24" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" FIRECODE "C" gypsumboard ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. Fill void(between dwelling units) with glass fiber mineral wool insulation installed between the floor trusses and supported bythe resilient channels. Provide 3-1/4" MDF Base.ASSEMBLIES (@ BASEMENTS):F2-WWOOD PLANKS ON CONCRETE SLABWood planks, installed per manufacturer's specifications, over concrete slab.Provide transitions strips where there is a material change in floor finish.F2-TTILE ON CONCRETE SLAB12"x12" Ceramic Tile on thin set mortar over concrete slab. Provide transitions strips where there is a material change in floor finish. Provide 4'-0" high, 12"x12" ceramic tilewainscoting on all restroom walls.F2-CTCERAMIC TILE ON CONCRETE SLABW" x H" Ceramic Tile (TBD) on thin set mortar over existing concrete slab.Provide transitions strips where there is a material change in floor finish. Provide 4'-0" high, 18"x18" ceramic tilewainscoting on all restroom walls.F2-SSTONE ON CONCRETE SLABW" x H" Stone (TBD) on thin set mortar over concrete slab.Provide transitions strips where there is a material change in floor finish. Provide 4'-0" high, 18"x18" ceramic tilewainscoting on all restroom walls.ASSEMBLIES (@ GARAGE):F3CONCRETE SLAB WITH GARAGE FINISHStructural concrete slab with sloped concrete topping. RE: Structure.Finish with a garage finish (TBD).C1GYPSUM BOARD CEILING CONSTRUCTION(1Hr-Rated) UL DESIGN NO. L521 & UL P5335/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses.(TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies.C2EXPOSED BEAMS WITH WOOD SIDING CEILING CONSTRUCTION(Non-Rated) Exposed rustic beams with rustic siding inlay. TBDCEILING SYSTEMS:FLOOR SYSTEMS:Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepanciesprior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to botharchitectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, soundand weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general.NOTES*Stone veneer to be installed in strict conformance with ESR Reports (ICC) for manufacturer selected.Comply with the Rocky Mountain Masonry Institute requirements & specifications for systems notevaluated by ICC, 2009 International Building Code requirements and industry recognized tradestandards.**Interior Walls Studs:4-2x4 Wood Studs6-2x6 Wood Studs8 -2x8 Wood StudsRE: See wall tags for stud sizes.****Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistantnon-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistantnon-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade whererecommended by manufacturer. Maintain required fire-rating.Refer to Structural Drawings for Bearing Walls and Shear Walls.RATED ASSEMBLIES (EXTERIOR):W1-WSWOOD SIDING @ RATED EXTERIOR WALLS(1-Hr. Fire Rated Assembly UL Design No. U356)Wood Siding on weather resistive barrier on (1) layer 5/8" gypsum sheathing @exterior face of 2x8 wood studs w/ R-20 batt insulation between studs. (1) layer 5/8" gypsum board @interior face of studs. (Re: Structural for size and spacing of studs and sheathing).W1-SV*STONE VENEER @ RATED EXTERIOR WALLS(1-Hr. Fire Rated Assembly UL Design No. U356)Stone veneer over wire lath with scratch coating on weather resistive barrier on (1) layer 5/8" osb sheathing@ exterior face of 2x8 wood studs w/ R-20 batt insulation between studs. (1) layer 5/8" gypsum board @ interiorface of studs. (Re: Structural for size and spacing of studs and sheathing).RATED ASSEMBLIES (EXTERIOR):W2 GYPSUM SHEATHING @ RATED INTERIOR GARAGE SEPARATION WALLS(1-Hr. Fire Rated Assembly UL Design No. U356)(1) layer 5/8" Type "X" gypsum sheathing @ garage interior face of 2x6 wood studs w/ R-20 batt insulationbetween studs. (1) layer 5/8" gypsum board @ non-garage face of studs. (Re: Structural for size and spacingof studs and sheathing).W3 GYPSUM SHEATHING @ UNIT SEPARATION WALLS(2-Hr. Fire Rated Assembly UL Design No. Uxxxx)PARTY WALL - (1) layer 5/8" Type "X" gypsum sheathing @ both sides of 2x6 wood studs w/ R-20 battinsulation between studs. 1" air cavity. (1) layer 5/8" Type "X" gypsum sheathing @ both sides of 2x6wood studs w/ R-20 batt insulation between studs.NON-RATED ASSEMBLIES (EXTERIOR):W4-*** GYPSUM BOARD PARTITION ON 2 x WOOD STUDS(Non-Rated)(1) Layer 5/8" gypsum board**** on each side of 2x wood studs at non-bearing walls demising bedroomsand living areas (Re. Structural for size and spacing).(1Hr-Rated) UL DESIGN NO. L521 & UL P533 ?????R1SYNTHETIC SHAKE SHINGLE ROOF CONSTRUCTION OVER CONDITIONED SPACE:(1-Hr. Fire Rated Assembly UL P533)50 year composite shingle (min. Class A, ASTM E 108) roofing on 30 lb. felt weather barrier (ice and water shield4' up from eaves and valleys) on 15/32" APA rated structural deck sheathing (U.N.O. on Structural Drawings) overPre-Engineered/Pre-Fabricated 8" Structural Insulated Panel (SIP). SIP panel to have (1) layer of 5/8" sheathingcontinuous on both sides of 8" expanded polystyrene foam (EPS) insulation. SIP panel on 1x decking which siton 8x12 structural rafters. (Re: Structural Dwgs)110 MPH Wind resistance (ASTM D 3161), Class 4 impact resistance (UL 2218), ICC-ES (ESR-2119), Miami DadeCode ApprovalROOF SYSTEMS:2X8 DIMENSIONALLUMBER @ 16" O.C.5/8" GYPSUMWALL BOARDINTERIOR8"-10" WOOD SIDINGEXTERIOR8" - 10" WOOD SIDINGBATT INSULATION,R-20 MIN.BUILDING WRAP5/8" STRUCTURALSHEATHING,RE: STRUCTUREW1-WS5/8" GYP. = 40 MIN.FIRE RATED: 1 HOUR MIN.2x8 FRAMING @ 16"O.C.= 20 MIN.BATT INSULATION = 15 MIN.FIRE RATING(1-HOUR MIN.) :SHEATHING = 20 MIN.2X8 DIMENSIONALLUMBER @ 16" O.C.5/8" GYPSUMWALL BOARDTYPE "X", TYP.INTERIORSTONE VENEEREXTERIORBATT INSULATION,R-20 MIN.BUILDING WRAPLATH WITHSCRATCH COAT5/8" STRUCTURALSHEATHING,RE: STRUCTURE5/8" GYP. = 40 MIN.FIRE RATED: 1 HOUR MIN.2x8 FRAMING @ 16"O.C.= 20 MIN.BATT INSULATION = 15 MIN.FIRE RATING(1-HOUR MIN.) :SHEATHING = 20 MIN.W1-SVWALL ASSEMBLIESEXTERIOR WALL ASSEMBLIES:INTERIOR WALL ASSEMBLIES:NOTE: ALL EXTERIOR WALLS TO HAVE A FIRE RATING OF 1 HOURMINIMUM. STRUCTURE TO HAVE FIRE SPRINKLER SYSTEM.FIRE RATED ASSEMBLIES:NON-RATED ASSEMBLIES:NON-RATED ASSEMBLIES @ FOUNDATION WALLS:5/8" GYPSUMWALL BOARD3 1/2"W4-42X4 DIMENSIONAL LUMBER@ 16" O.C., SEE PLANS ANDWALL TAG FOR LUMBER SIZE, TYP.5/8" GYPSUMWALL BOARD5 1/2"W4-62X6 DIMENSIONAL LUMBER@ 16" O.C., SEE PLANS ANDWALL TAG FOR LUMBER SIZE, TYP.2X8 DIMENSIONAL LUMBER@ 16" O.C., SEE PLANS ANDWALL TAG FOR LUMBER SIZE, TYP.5/8" GYPSUMWALL BOARD7 1/4"W4-85/8" GYPSUMWALL BOARD,TYPE X, TYP.5 1/2"W22X6 DIMENSIONAL LUMBER@ 16" O.C.,TYP.5 1/2"1"1" AIR CAVITY, TYP.BATT INSULATION, TYP.5/8" GYP. = 40 MIN. X4FIRE RATED: 2 HOUR MIN.2x8 FRAMING (X2) @ 16" O.C.= 20 MIN. X2BATT INSULATION = 15 MIN. X2FIRE RATING(2-HOUR MIN.) :5/8" GYPSUMWALL BOARD,TYPE X, TYP.5 1/2"W32X6 DIMENSIONAL LUMBER@ 16" O.C.,TYP.BATT INSULATION, TYP.5/8" GYP. = 40 MIN. x2FIRE RATED: 1 HOUR MIN.2x8 FRAMING (X2) @ 16" O.C.= 20 MIN.BATT INSULATION = 15 MIN.FIRE RATING(1-HOUR MIN.) :INTERIORGARAGEFOUNDATION WALL,RE: STRUCTURE, TYP.5/8" GYPSUMWALL BOARDW51 1/2" METAL FURRING@ 16" O.C., TYP.1 1/2" RIGID INSULATIONBETWEEN FURRING, TYP.1650 Fallridge Road, Suite C-1Vail, Colorado 81657f.(970) 476-4901 p.(970)476-6342182 WEST MEADOW DRIVEVAIL, CO 81657A0.09ASSEMBLIESPIETRINI RESIDENCEProject Number - 142809/05/14PERMIT SET 3" = 1'-0"1W1-WS - WOOD SIDING 2X8 3" = 1'-0"2W1-SV STONE VENEER 2X8 1 1/2" = 1'-0"5INTERIOR PARTITION (2X4) W4-4 1 1/2" = 1'-0"6INTERIOR PARTITION (2X6) W4-6 1 1/2" = 1'-0"7INTERIOR PARTITION (2X8) W4-8 1 1/2" = 1'-0"3INTERIOR UNIT SEPARATION W2 1 1/2" = 1'-0"4GARAGE SEPARATION W3 1 1/2" = 1'-0"8INTERIOR FINISH - W-5