HomeMy WebLinkAboutE000 COVER SHEET.pdf ' ABOVE SEA LEVELPROJECT ALTITUDE8100'*' ISSUED FOR INFORMATION ONLY' ' NOT PART OF SET' ' ISSUED AS PART OF A SETISSUE LOG KEY:#DATEISSUE LOGELECTRICAL SHEET INDEXTITLEELECTRICAL COVER SHEETE0.00PERMIT SET09.05.14BASEMENT ELECTRICAL PLANE2.00MAIN FLOOR ELECTRICALPLANE2.10SECOND FLOOR ELECTRICAL PLANE2.20E3.00ELECTRICAL DIAGRAMSGENERAL NOTES:GFCI DUPLEX RECEPTACLEDUPLEX RECEPTACLE; HALF SWITCHED ISOLATED GROUND DUPLEX RECEPTACLE WALL MOUNTED SPECIAL OUTLET AS NOTEDSPECIAL OUTLET AS NOTEDJUNCTION BOXWALL MOUNTED JUNCTION BOXFLOOR MOUNTED JUCTION BOXDUPLEX RECEPTACLE MOUNTED ABOVE CONTERCFLUSH FLOOR MOUNTED DUPLEX RECEPTACLEFLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLEFLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHEDFLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOMDIVISION 15 EQUIPMENT POWER CONNECTIONFUSED DISCONNECTNON FUSED DISCONNECTMOTOR STARTERENCLOSED CIRCUIT BREAKERPULL BOXPUSH BOTTONTRANSFORMERPANELBOARD OR LOADCENTERCONTACTORELECTRIC MOTORMETERTHERMOSTATATSAUTOMATIC TRANSFER SWITCHONE-LINE DIAGRAM SYMBOLSCIRCUIT HOMERUNCONDUIT RUNCONDUIT RUN BELOW GRADECONDUIT UPCONDUIT DOWNDISCONNECT SWITCHFUSECIRCUIT BREAKERCURRENT TRANSFORMERPOTENTIAL TRANSFORMERMETERSURGE SUPPRESSION DEVICEVOLT-METERSELECTOR SWITCHGROUNDGFGROUND FAULT PROTECTIONAMP-METERSTSHUNT TRIPNORMALLY OPEN CONTACTNORMALLY CLOSED CONTACTCOLD WATER GROUND CONNECTIONBUILDING STEEL GROUND CONNECTIONLIGHTING SYMBOLSRECESSED LIGHTING FIXTUREWALL MOUNTED LIGHTWALL MOUNTED UP-LIGHTPENDANT MOUNTED LIGHTSURFACE MOUNTED LIGHTDIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTUREMONO-POINT LIGHTING FIXTURERECESSED STEP LIGHTFLUORESCENT STRIP LIGHTWALL MOUNTED LINEAR FLUORESCENT LIGHTRECESSED OR SURFACE MOUNTED FLUORESCENT TROFFERFIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUITWALL MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN EMERGENCY LIGHTSCEILING MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN TIMER SWITCHMULTI-OUTLET PLUG STRIPTIME CLOCKPHOTO-CELLSWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHDOOR JAMB SWITCHKEY SWITCHLVVARIABLE SPEED SWITCHDIMMERTHREE-WAY DIMMERLOW VOLTAGE SWITCHWALL OCCUPANCY SENSOR/SWITCHTHERMAL OVERLOAD SWITCHSMALL ROOM OCCUPANCY SENSORLARGE ROOM OCCUPANCY SENSORCORRIDOR OCCUPANCY SENSORFIRE ALARM SYMBOLSFIRE ALARM CONTROL PANELREMOTE ANNUNCIATOR PANELSMOKE DETECTORHEAT DETECTORCOMBO SMOKE/HEAT DETECTORFIRE ALARM HORNFIRE ALARM STROBEFIRE ALARM COMBO HORN/STROBEFIRE ALARM PULL STATIONFFIRE ALARM SPEAKERFFIRE ALARM COMBO SPEAKER/STROBEFIREMAN'S PHONE JACKDUCT SMOKE DETECTORSPRINKLER SYSTEM FLOW SWITCHSPRINKLER SYSTEM TAMPER SWITCHINDICATES DEMOLITION.NOTE: LIGHT LINEWEIGHT INDICATES EXISTING.NOTE: ALL SYMBOLS SHOWN ON LEGENDARE NOT NECESSARILY USED.FIRE/SMOKE DAMPERTELECOMMUNICATION SYMBOLSPHONE OUTLETDATA OUTLETCOMBO PHONE/DATA OUTLETFLOOR MOUNTED TELEVISION OUTLETWALL MOUNTED TELEVISION OUTLETCLOCK OUTLETCEILING MOUNTED SPEAKERWALL MOUNTED SPEAKERVOLUME CONTROLFLOOR MOUNTED MICROPHONE OUTLETWALL MOUNTED MICROPHONE OUTLETINTERCOM STATIONCHIMEPHONE FLOOR OUTLETDATA FLOOR OUTLETCOMBO PHONE/DATA FLOOR OUTLETABBREVIATIONSAVC - ABOVE FINISHED CEILINGAFF - ABOVE FINISHED FLOORAFG - ABOVE FINISHED GRADEAL - ALUMINUMBFG - BELOW FINISH GRADEC - CONDUITCKT - CIRCUITCT - CURRENT TRANSFORMEREM - EMERGENCYEWC - ELECTRIC WATER COOLER(E) - EXISTINGFBO - FURNISHED BY OWNERGRD - GROUNDGFI - GROUND FAULT CIRCUIT INTERRUPTERIG - ISOLATED GROUNDIAW - IN ACCORDANCE WITHNIC - NOT IN CONTRACTDW - DISHWASHERDISP - GARBAGE DISPOSALNL - NIGHT LIGHTNTS - NOT TO SCALEREF - REFRIGERATORSPD - SURGE PROTECTIVE DEVICEUG - UNDERGROUNDUNO - UNLESS NOTED OTHERWISEWP - WEATHER PROOFXP - EXPLOSION PROOF+18" - MOUNTING HEIGHT TO CENTERLINE OF DEVICE ABOVE FINISH FLOORDAYLIGHT PHOTO SENSORDL--JJJPCTCTSTCTPBCBNSTSOD3DSVSKSJS4S3SOCOCOCCHICMMVSTVTVFSDFTFFDDFFHSHHDSDANNFACPAVSSMELECTRICAL LEGENDPOWER SYMBOLSSINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE NO SCALETYPICAL DEVICE ALIGNMENTEQ EQ6"MIN. ℄℄℄DOOR WINDOWEQ EQ℄LIGHTINGCONTROL℄℄OFFSET COMMUNICATIONSDEVICES FROM POWERDEVICES TO EITHEROPPOSITE SIDE OF STUD BAY,OR ADJACENT STUD BAY.1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN CONFLICTWITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADADIMENSIONS SHALL GOVERN.2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS.LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALLSUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONSSHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT.EQBACKSPLASHABOVECOUNTERDEVICERECEPTACLECOUNTERTOPEQFINISHED FLOORFINISHED CEILING6"MIN.20"MAX.ALIGN DEVICES (OUTLETS,CONTROLS, ETC.)VERTICALLY. DO VERTICALLY ALIGN POWERAND COMMUNICATIONSDEVICES SIMULTANEOUSLY.18" 48" 64" 78"90"78"64" 90"6"MIN FIRE ALARM DEVICES48" ELECTRICAL DEVICES96"1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS INCONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATIONDETAIL, ADA DIMENSIONS SHALL GOVERN.2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS.LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALLSUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONSSHOWN ON INTERIOR ELEVATIONS ARE NOT CODECOMPLIANT.WALL-MOUNTNO SCALETYPICAL DEVICE MOUNTING HEIGHTSOCDLVSCBCTSTCANNFACPSHSHF120"MAX.80"MIN.96"MAX.TOP OF DEVICE9'-0"+ CEILING8'-0" CEILINGTOP OF CABINETTOP OF CABINETTOP OF DEVICECL OF DEVICETOP OF DEVICETOP OF CABINETTOP OF CABINETBOTTOM OF DEVICEMINIMUM, TOP OF DEVICEFINISHED FLOORFINISHED CEILING1. THESE DRAWINGS ACCOMPANY THE PUBLISHED CONSTRUCTION DOCUMENT SPECIFICATION BOOK (PROJECT MANUAL).2. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OFWORK.3. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTSREQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS.4. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER - IN WRITING. WORK WHICH COULD RESULT IN ANACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISEDOF SUCH WORK.5. REVIEW ARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID.6. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT.7. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES ANDORDINANCES.8. PROVIDE PERMITS AND INSPECTIONS REQUIRED.9. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS AREASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.10. VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND UTILITIES, PIPING AND RACEWAY SYSTEMS PRIOR TOTRENCHING. PROVIDE NECESSARY TRENCHING, BACKFILL, EXCAVATION, SUPPORTS, SERVICE FEEDERS (CONDUIT AND/OR WIRE),PULLBOXES, TRANSFORMER PADS, SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC. REQUIRED. BACKFILL TRENCHES TO 90PERCENT COMPACTION AND PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANYDRAWINGS AND REQUIREMENTS. ELECTRICAL CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THEELECTRICAL UTILITY COMPANY WITH-IN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THEIR REVIEW, APPROVAL,CONSTRUCTION SCHEDULING AND INSTALLATION OF THE UTILITY TRANSFORMER WITH THE UTILITY COMPANY. NOTIFY OWNER OFANY SCHEDULING CONFLICTS.11. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN.12. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHTTO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION.13. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS,AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLEWITH EQUIPMENT ACTUALLY SUPPLIED.14. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRINGPROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION.15. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY.16. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 20 AMPERES FORDUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT.17. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION,PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT,ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT.18. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTSWIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREECELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS.19. PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIESSHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS.20. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVEDFITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT.21. FIRE ALARM, SOUND, TELEPHONE, COMPUTER AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1” SHALL HAVE LONG RADIUSSWEEPS (12 TIMES THE DIAMETER).22. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKECORRECTIONS NECESSARY AT NO COST TO OWNER.23. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGEFOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THEOWNER.24. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES,MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE.25. PROVIDE TAMPER RESISTANT RECEPTACLES IN ACCORDANCE WITH NEC 406.12.26. PROVIDE ARC-FAULT PROTECTED CIRCUIT BREAKERS FOR ALL 120 VOLT CIRCUITS IN ACCORDANCE WITH NEC 210.12.182 WEST MEADOW DRIVEVAIL, CO 81657PIETRINI RESIDENCEProject Number - 142807/30/14DESIGN REVIEWCOPYRIGHT 2014BANZEGEAUDIN(970) 949-6108(303) 278-3820(970) 221-5691(505) 323-9070(307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com09/05/14PERMIT SETE0.00ELECTRICALCOVERSHEET