Loading...
HomeMy WebLinkAboutM000 COVER SHEET.pdf ' ABOVE SEA LEVELPROJECT ALTITUDE8100'*' ISSUED FOR INFORMATION ONLY' ' NOT PART OF SET' ' ISSUED AS PART OF A SETISSUE LOG KEY:#DATEISSUE LOGMECHANICAL SHEET INDEXTITLEMECHANICAL COVER SHEETM0.00PERMIT SET09.05.14MECHANICAL SCHEDULES M0.10MECHANICAL SCHEDULES M0.20MECHANICAL SITE PLANM1.10BASEMENT PIPING PLANM2.00MAIN FLOOR PIPING PLANM2.10SECOND FLOOR PIPING PLANM2.20M3.00M3.10M3.20MECHANICAL DIAGRAMSM4.00BASEMENT MECHANICAL PLANMAIN FLOOR MECHANICAL PLANSECOND FLOOR MECHANICAL PLANMECHANICAL SPECIFICATIONSM0.30MECHANICAL CONTROLSM5.00FIXTURE CONNECTION SCHEDULEWCWATER CLOSET (FLUSH VALVE)ABBREV.-HW1"CW4"WASTE2"VENT:1. SIZES SHOWN ARE MINIMUM PIPE SIZES TO A SINGLE FIXTURE. LARGER SIZES MAY BEINDICATED ON PLANS WHERE REQUIRED.2. MINIMUM DOMESTIC PIPE SIZE TO 2 OR MORE FIXTURES IS 3/4".3. RE: MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR INDIRECT WASTE SIZES.4. WASTE AND VENT SIZES SHOWN ABOVE APPLY TO INDIVIDUAL VENTING ONLY. WHEREALLOWED, INDIVIDUAL VENT CONNECTIONS MAY BE OMITTED OR SIZES MAY VARYWHEN CIRCUIT VENTS, COMMON VENTS, WASTE STACK VENTS, WET VENTS, ORCOMBINATION DRAIN AND VENT SYSTEMS ARE USED. PRIOR APPROVAL FROM THEENGINEER IS REQUIRED TO USE THESE ALTERNATIVE VENTING METHODS.5. PROVIDE TRAP PRIMER FOR ALL FLOOR DRAINS AND FLOOR SINKS NOT LOCATED INFOOD SERVICE AREAS.6. MINIMUM SIZE FOR WASTE AND VENT PIPING BENEATH SLAB IS 2".7. ALL FIXTURES LISTED ARE NOT NECESSARILY USED ON THIS PROJECT.8. REFER TO APPLIANCE SCHEDULES (BY OTHERS) FOR ADDITIONAL PLUMBING FIXTURECONNECTIONS SUCH AS INST-HOTS, COFFEE MAKERS, AND GARBAGE DISPOSALS.9. PROVIDE ICE MAKER BOX ROUGH IN W/ 1/2"CW CONNECTION FOR ALL REFRIGERATORLOCATIONS.WATER CLOSET (FLUSH TANK)URINAL (BLOWOUT)URINAL (WASHDOWN)URINAL (WATERLESS)LAVATORYHAND SINKSERVICE SINKMOP SERVICE BASINDRINKING FOUNTAIN / E.W.C.KITCHEN SINK W/ OR W/O DISPOSERBATHTUB / SHOWERCLOTHES WASHER ROUGH-INDISH MACHINE ROUGH-INDISHWASHER ROUGH-INBAR SINKFLOOR SINKFLOOR DRAINTROUGH DRAINWORK SINKHOSE BIBWCT - 1/2" 4" 2"UR 1" 2" 1-1/2"UR 3/4" 2" 1-1/2"UR - 2" 1-1/2"LAV 1/2" 1-1/2" 1-1/2"HS 1-1/2" 1-1/2"SS 3" 2"MSB 3/4" 3" 2"DF - 1/2"KS 1/2" 1/2" 2"SH 3/4" 3/4" 2"CW 1/2" 1/2" 2"DMDWBSFSFDTDWSHB---1/2"1/2"1/2"3/4"1/2"1/2"1-1/2" 1-1/2"1-1/2"1-1/2"1-1/2"-1/2"1/2" 1/2"3/4" 3/4" 2" 1-1/2"2" 1-1/2"1-1/2"1-1/2"---------3/4"3/4"3/4"3"3"2"2"2"2"1-1/2"1-1/2"PRESSURE REDUCING VALVEFLOW SWITCHSHOCK ABSORBERHOSE BIBBSTRAINER W/ BLOW-OFF VALVEROOF DRAINSAFETY RELIEF VALVEFLOOR DRAINFLOOR SINKHORIZONTAL CLEANOUTVACUUM BREAKERVERTICAL CLEANOUTPRESSURE GAUGE W/ PIG TAIL & COCKTHERMOMETERPRESSURE - TEMP. TAPAIR VENTPIPE ANCHORFLEXIBLE CONNECTORPIPE EXPANSION JOINTPIPE UNIONDOUBLE CHECK BACKFLOW PREVENTERPUMP & EQUIPMENT CONNECTORWALL HYDRANTTEMPERATURE CONTROL VALVE (2-WAY)DRAIN VALVE W/ HOSE ENDPLUG VALVE IN RISERFLOW BALANCING VALVEGATE OR GLOBE VALVE IN RISERFLOW CONTROL VALVEBALL VALVEPLUG OR BALANCING VALVECHECK VALVEGLOBE VALVEBUTTERFLY VALVEVENTURI/FLOW INDICATORTEMPERATURE CONTROL VALVE (3-WAY)SOLENOID VALVETEMPERATURE CONTROLLER OR SENSOR90° ELBOW UPTEE UPTEE DOWNDECK/ROOF DRAIN ABOVESHUT OFF (BALL, GATE, BUTTERFLY)PIPING SYMBOLS90° ELBOW DNH BW HFSSTCPLAN SYMBOLSCONTROL PANEL/RADIANT MANIFOLDT----P---SHCOPEPOCO2SPCARBON DIOXIDE SENSORCARBON MONOXIDE SENSORFIRE RISERDIAGRAM CONTINUATION REFERENCEPLUMBING RISERHEATING WATER RISERTHERMOSTATHVAC RISERPOINT OF NEW CONNECTIONDUCT STATIC PRESSURE SENSORROOM PRESSURE SENSORHUMIDISTATREMOTE TEMPERATURE SENSOREMERGENCY POWER OFF SWITCHACCESS PANELSNOWMELT MANIFOLDSECTION CUT LETTER/SHEET SHOWN ON POINT OF DISCONNECTIONTYPE OF AIR DEVICE RE:GRD SCHEDULE.AIR DEVICE DESIGNATION KEY# = AIR QUANTITY (CFM)CA = COMB. AIROSA = OUTSIDE AIRRET = RETURNEXH = EXHAUSTXFR = TRANSFERSIZE (INCHES) OR MINIMUMFREE AREA REQUIRED INSQUARE FEETA15012x6NOTE: FOR STANDARD MODULE SIZEREGISTERS, SIZE GIVEN IS NECKSIZE. REFER TO GRD SCHEDULEFOR MODULE SIZE.BXFR12x6INDICATES AIR INLET DEVICEREFERENCE SAMPLEFFI = FOR FURTHER INFORMATIONFCT = FOR CONTINUATIONSHEET NUMBERDRAWING NUMBER OR DIAGRAMLETTERREFER TO:RE: B/M400 FFINOTES1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONSON LEGEND SHEET ARE NOT NECESSARILY USED ONTHIS PROJECT.2. THIS DRAWING SET CONSISTS OF DATA GENERATED, INPART, BY OTHER PARTIES. NOT ALL SYMBOLOGIESAND NOTATION CONVENTIONS OCCURRING IN THISDRAWING SET ARE NECESSARILY DEFINED ON THESELEGENDS. CONSULT THE ENGINEER IN THE EVENTSYMBOLOGY OR NOTATION INTERPRETATION ISREQUIRED.PIPING DESIGNATIONSSNOWMELT SUPPLYSNOWMELT RETURNHEATING WATER SUPPLY (HIGH TEMP)HEATING WATER RETURN (HIGH TEMP)CHILLED WATER SUPPLYCHILLED WATER RETURNNATURAL GASMEDIUM PRESSURE GASREFRIGERANT SUCTIONREFRIGERANT LIQUIDDOMESTIC WATER (CW / DW)DOMESTIC HOT WATER (HW / DHW)DOMESTIC HOT WATER (TEMP. SHOWN)DHW RECIRCULATION (HWC / DHR)FIRE LINEPRESSURIZED WASTEPLUMBING VENT PIPEWASTE PIPESTORM DRAIN PIPESTORM DRAIN OVERFLOWLIQUID PROPANE GASSECONDARY DRAINSAND AND OIL WASTEPROPANE GASHEATING WATER SUPPLY (LOW TEMP)HEATING WATER RETURN (LOW TEMP)SOLAR HEATING WATER SUPPLYSOLAR HEATING WATER RETURNHEATING WATER SUPPLYHEATING WATER RETURNDRAIN PIPEGLYCOL FEEDHEATING WATER RETURN (HEAT PUMP)HEATING WATER RETURN (HEAT PUMP)PROPANE DRAINHYDRONIC PIPINGHWS(HT)HWR(HT)HWS(LT)HWR(LT)HWSHWRGFHWS(HP)HWR(HP)CHSCHRSMRSMSSHWSSHWRPLUMBING PIPINGGMGLPGPGDPDNS140°RLRSNON-SOFTENED DOMESTIC WATER PWWVSTSDSOST(OF)FDUCTWORK LEGENDSINGLE LINEDOUBLE LINEDESCRIPTION90° ELBOW DOWN (ROUND DUCT ONLY)ROUND 90° ELBOW UP (ROUND DUCT ONLY)ROUND RADIUS ELBOW90° STRAIGHT TEE90° CONICAL TEE45° BRANCH45° CONICAL TEESIZE OR SHAPE TRANSITIONROUND FLEXIBLE DUCT90° ELBOW DN (NEGATIVE PRESSURE)90° ELBOW DN (POSITIVE PRESSURE)90° ELBOW UP (NEGATIVE PRESSURE)90° ELBOW UP (POSITIVE PRESSURE)90° RADIUS ELBOW90° RADIUS ELBOW W/TURNING VANESSQUARE DUCT SPLITROUND DUCT SPLITCOMBINATION FIRE AND SMOKE DAMPER FIRE DAMPER SMOKE DAMPERMOTOR OPERATED DAMPER (MOD) BACKDRAFT DAMPER SMOKE DETECTOROFFSET TO CHANGE ELEVATION(AT 30° WHEN POSSIBLE)D = DROP R = RISEDF/SBDDSD24x36DSPLIT BRANCH TAKE-OFF WITH SQUAREELBOW & SPLITTER DAMPERSPLIT BRANCH TAKE-OFF WITH RADIUSELBOW & SPLITTER DAMPERPOSITIVE PRESSURE RISER, TYPICALLYSUPPLY.NEGATIVE PRESSURE RISER, TYPICALLYRETURN, EXHAUST OR OUTSIDE AIR.MAN VOLUME DAMPER, SINGLE BLADEDAMPER(SBD) FOR ROUND OR <10" TALL,OPPOSED BLADE DAMPER(OBD) >10" TALL.DUCT SIZE: FIRST NUMBER IS PLAN WIDTH,SECOND NUMBER IS DEPTH.24x36SDF/SBDDPLAN ABBREVIATIONSABOVE FINISHED FLOORAIR ADMITTANCE VALVEABOVE FINISHED GRADEAUTOMATICBUILDING CONTROL SYSTEMBACK DRAFT DAMPERBUILDINGAAVAFFAFGAUTOBCSBDDBLDGBOTTOM OF PIPE FROM FINISHED FLOORBETWEENCOMMONCOMBUSTION AIRCONTROLS CONTRACTORCONTINUATION DESIGN BUILD BOPB/NCCACCCDBBCCUBIC FEET PER MINUTE (AIR FLOW RATE)CAST IN PLACECEILING (OR COOLING)CONCRETECONDENSATECONNECTCONTRACTORCFMCIPCLGCONCCONDCONNCONTR'RCLEANOUTCOCLEANOUT TO GRADECOTGDOMESTIC HOT WATER RECIRCEXISTINGDWR(E)EXHAUST AIREAENTERING AIR TEMPERATUREELECTRICAL CONTRACTORENTERING WATER TEMPERATUREEATECEXH EXHAUSTEWTGENERAL CONTRACTORGROUND HEAT EXCHANGER GCGHXGALLONS PER MINUTE (WATER FLOW RATE)GPMHORSEPOWERHOT WATERIN LIEU OFHPHWILOKILOWATTSKWLEAVING AIR TEMPERATURELINEAR FOOTLEAVING WATER TEMPERATURELATLFLWTMECHANICAL CONTRACTORMCMANUFACTURERMOTOR OPERATED DAMPERNEWMFGMOD(N)NORMALLY CLOSEDNCNATIONAL ELECTRIC CODENOT IN CONTRACTNORMALLY OPENNECNICN0OUTSIDE AIROAOPPOSED BLADE VOLUME DAMPERON CENTEROBDOCOUTSIDE AIROSARETURN AIRREQUIREDRAREQ'DREQUIREMENTSREQ'MTSSUPPLY AIRSQUARE FOOT (FEET)SASFSTATIC PRESSURESPSTAINLESS STEELTHROW-AWAYTYPICALSST.A.TYPUNLESS NOTED OTHERWISEUNOVENT THRU ROOFVTRWALL CLEANOUTWCOWITH REGARD TOWATER COOLEDTRANSFERWRTW/CXFRDIAMETERØBY CONTRACTORCOLD WATERCWHOT WATER RECIRCHWCABOVEABVBELOW FINISHED GRADEBFGDOMESTIC WATERDOMESTIC HOT WATERDWDHWDOWNDNDOMESTIC HOT WATER RECIRCDHRCOMBINATION FIRE/SMOKE DAMPERFURNISHED BY OWNERFSDFBOFLOOR CLEANOUTFCOFOR CONTINUATIONFCTFD FIRE DAMPERREFER TO:RE:WITHW/EQUIPMENT ABBREVIATIONSAIR HANDLING UNITAHUAIR SEPARATORASBOILER (HOT WATER)BBASE BOARDBBBUFFER TANKBTCONSTANT VOLUME BOXCVDISHWASHER EXHAUST FANDEFELECTRIC BASEBOARD HEATEREBHFURNACEFFAN COILFCFAN POWERED BOXFPGLYCOL FEEDERGFHUMIDIFIERHC HEATING COILHP HEAT PUMPHXHEAT EXCHANGERKITCHEN EXHAUST FANKEFMAKE-UP AIR UNITMAUMOTOR CONTROL CENTERMCCMIXING VALVEMVPUMP (SEE PIPING LEGEND FOR DETAILS)PRETURN (OR RELIEF) AIR FANRFRADIANT ZONERZSNOWMELT AREASASUMP BASINSBSUPPLY FANSFSTORAGE TANKSTTHERMOSTATIC MIXING VALVETMVUNIT HEATERUHVARIABLE VOLUME BOXVVWATER HEATERWHHCHILLERCHCOILING COILCCCIRC PUMPCPCABINET UNIT HEATERCUHCOOLING TOWERCTDUCT COILDCELECTRIC WATER HEATEREWHEVAPORATIVE COOLING UNITECUENERGY RECOVERY UNITERUEXHAUST FANEFEXPANSION TANKETVARIABLE VOLUME BOX W/ REHEATVRMECHANICAL DIAGRAMSM4.01MECHANICAL CONTROLSM5.01MECHANICAL CONTROLSM5.021. FIRE PROTECTION ELEMENTS SHOWN HEREIN ONEFOR COORDINATION PURPOSES ONLY. THEENGINEERING SEAL AFFIXED TO ANY PART OF THISDOCUMENT SET AND ANY RESPONSIBILITY OFENGINEER OF RECORD EXPRESSLY EXCLUDES ANYAND ALL FIRE PROTECTION ELEMENTS SHOWNHEREIN.2. THE FIRE PROTECTION CONTRACTOR WHO IS THEWINNING BIDDER SHALL RETAIN THE SERVICES OF AREGISTERED PROFESSIONAL FIRE PROTECTIONENGINEER. SAID FIRE PROTECTION ENGINEER SHALLPERFORM ALL DESIGN CALCULATIONS, PROVIDE ACOMPLETELY DESIGNED FIRE PROTECTION SYSTEMIN A SEPARATE DOCUMENT SET, AND SHALL BE THEENGINEER OF RECORD FOR THE FIRE PROTECTIONSYSTEM.3. THE FIRE PROTECTION SYSTEM SHALL BE DESIGNEDIN ACCORDANCE WITH NFPA, LOCAL CODES ANDORDINANCES, AND FACTORY MUTUAL WHEREAPPLICABLE.FIRE PROTECTION NOTES:MECHANICAL VENTILATION (NATURAL VENTILATION)SPACEAREA SQ. FT.CFM/SQ.FT.OR ACHAREA CFM PEOPLE CFM/PERSON PEOPLE CFMVbz (MAX OFAREA ANDPEOPLE CFM)ZONEEFFECTIVENESSEzZONEOUTDOORAIRFLOW (Voz)VotALL OCCUPIEDSPACES ON MAINAND UPPER LEVELSSERVED BY OPERABLE WINDOWS, 4% OR GREATER IN FREE AREA OF FLOOR SPACE SERVEDBEDROOMS ONLOWER LEVELSSERVED BY OPERABLE WINDOWS, 4% OR GREATER IN FREE AREA OF FLOOR SPACE SERVEDGAME ROOM ANDBAR, LOWER LEVEL800 SQ.FT. X 9FTCEILINGS0.35 ACH 428 15 120 120 0.8 150 150PERRESIDENCEA/B SIDES182 WEST MEADOW DRIVEVAIL, CO 81657PIETRINI RESIDENCEProject Number - 142807/30/14DESIGN REVIEWCOPYRIGHT 2014BANZEGEAUDIN(970) 949-6108(303) 278-3820(970) 221-5691(505) 323-9070(307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com09/05/14PERMIT SETM0.00MECHANICALCOVERSHEET