Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M010 SCHEDULES.pdf
GRILLE, REGISTER, DIFFUSER & LOUVERSYMBOL USE PATTERN FINISHMANUFACTURER* &MODEL #ACCESSORIES REMARKSSIDEWALLSUPPLY/ RETURNLINEAR BAR RE: ARCH KRUEGER 1600CABLE OPERATEDDAMPER WHEREAIRFLOW IS LISTED15° DEFLECTION, 1/4" SPACING,1/8" BAR THICKNESS,CONCEALED MNT'ING, FRAME RGCEILING SUPPLY/RETURN/EXHLINEAR BAR RE: ARCH KRUEGER 1600CABLE OPERATEDDAMPER WHEREAIRFLOW IS LISTED15° DEFLECTION, 1/4" SPACING,1/8" BAR THICKNESS,CONCEALED MNT'ING, FRAME RGFLOOR/SILLSUPPLYLINEAR BAR RE: ARCHKRUEGER1850O.B.D.15° BLADE DEFLECTION, FRAMESTYLE N, NO MOUNTING, 1/8"BARS, 1/4" SPACINGFLOOR RETURN LINEAR BAR RE: ARCHKRUEGER1850-0° BLADE DEFLECTION, FRAMESTYLE N, NO MOUNTING, 1/8"BARS, 1/4" SPACINGEXH/OSA STATIONAIRY RE: ARCH - - - MANUFACTURERS:GRD METALAIRE, TITUSLOUVER GREENHECK, L&D, RUSKIN GENERAL NOTES:A:B:ABCDEEXHAUST FAN SCHEDULEMARK TYPEFAN MOTORMANUFACTURER*& MODEL #ACCESSORIES REMARKSCFM SONESESPHP/(WATT)VOLT/PHASE@ S.L. (INWC)@ ALT (INWC)EF-1 CEILING75 0.5 0.35 0.2512 W 120/1 PANASONIC FV-08VK3BACKDRAFT DAMPER,ISOLATORSPOWDER ROOMS-RESEF-2 CEILING110 1.5 0.35 0.2542 W 120/1PANASONIC FV-20VQ3BACKDRAFT DAMPER,ISOLATORSBATHROOMS-RESEF-3CEILING300 3.9 0.6 0.5 97 W120/1 COOK GC720BACKDRAFT DAMPER,FAN SPEED CONTROLISOLATORS, GRILLEMECH/ELECT ROOMSEF-4 CEILING200 2.0 0.3 0.2 64 W120/1PANASONIC FV-30VQ3BACKDRAFT DAMPER,ISOLATORSGARAGES MANUFACTURERS: * COOK, GREENHECK, PENN GENERAL NOTES:A:B:FAN COIL SCHEDULE (HYDRONIC)MARK SERVICE TYPEFAN COOLING COIL HEATING COILFILTERMANUFACTURER*& MODEL #ACCESSORIES REMARKSCFMO.S.A.CFMESP ELECTRICAL AIR CONDITIONS WATER CONDITIONS AIR CONDITIONS WATER CONDITIONS@ S.L.(IN WC)@ ALT(IN WC)HPVOLT/PHE.A.T.DB/WB(°F)L.A.T.DB/WB(°F)TOTALMBHSENSIBLEMBHE.W.T.(°F)L.W.T.(°F)GPMMAX.WTRP.D. (FT.)E.A.T.DB (°F)L.A.T.DB (°F)SENSIBLEMBHE.W.T.(°F)L.W.T.(°F)GPMMAX.WTRP.D. (FT.)FC-1AGAMEROOMHORIZ. 300 120 0.4 0.3 1/6 120/1 NO COOLING 34 95 8 140 110 0.6 102" TACARRIER 42CE -PROVIDE SPACE FOR FUTURE3-ROW CHILLED WATER COILFC-2ABUNKROOMSHORIZ. 200 50 0.5 0.4 1/6 120/1 NO COOLING 48 95 5 140 110 0.4 102" TACARRIER 42CE -PROVIDE SPACE FOR FUTURE3-ROW CHILLED WATER COILFC-3ALIVING/DININGHORIZ.1,500 1,0000.6 0.52240/175/6382/60^55/5260/54^322745 557.110 70/10^ 95/80^ 38/87^ 140 110 2.6/6.1^ 102" TACARRIER 42BHE - 4-ROW HEATING COILFC-4A MASTER 1 HORIZ. 600 0 0.4 0.3(2) 1/12120/1 75/63 55/5211945 552.710 70 9512140 110 1.0 102" TACARRIER 42CE - -FC-5ABED 1/STAIRSHORIZ. 900 0 0.4 0.3 3/4 120/1 75/63 55/52171545 554.4 10 70 95 20 140 110 1.6 102" TACARRIER 42BHE - -FC-6A MASTER 2 HORIZ. 600 0 0.4 0.3(2) 1/12120/1 75/63 55/52 9 845 552.9 10 70 9511140 1101.110 2" TA CARRIER 42CE - -FC-7A BEDS 2/3 HORIZ. 400 0 0.5 0..4 1/6 120/1 75/63 55/52 8 745 551.8 10 70 95 10 140 110 0.7 10 2" TA CARRIER 42CE - -FC-1BGAMEROOMHORIZ. 400 120 0.4 0.3 1/6 120/1 NO COOLING 36 95 8 140 110 0.6 10 2" TA CARRIER 42CE -PROVIDE SPACE FOR FUTURE3-ROW CHILLED WATER COILFC-2BBUNKROOMSHORIZ. 200 50 0.5 0.4 1/6 120/1 NO COOLING 48 955140 110 0.4 10 2" TA CARRIER 42CE -PROVIDE SPACE FOR FUTURE3-ROW CHILLED WATER COILFC-3BLIVING/DININGHORIZ.1,700 1,0000.6 0.5 2 240/175/6381/60^55/5260/54^32 2745 557.1 10 70/16^ 95/80^ 40/90^ 140 110 2.8/6.3^ 10 2" TA CARRIER 42BHE - 4-ROW HEATING COILFC-4B MASTER 1 HORIZ. 500 0 0.4 0.3 1/6 120/1 75/63 55/52 8 745 552.2 10 70 95 8 140 110 0.7 10 2" TA CARRIER 42CE - -FC-5B BED 1 HORIZ. 300 0 0.4 0.3 1/6 120/1 75/63 55/525445 551.7 10 70 955140 110 0.4 10 2" TA CARRIER 42CE - -FC-6BMASTER 2/STAIRSHORIZ.1,2000 0.4 0.3 1/6 120/1 75/63 55/52 21 1945 55 5.410 70 95 21 140 110 1.7 10 2" TA CARRIER 42BHE - -FC-7B BEDS 2/3 HORIZ. 500 0 0.5 0.1 1/6 120/1 75/63 55/52 7 645 551.8 10 70 95 10 140 110 0.7 10 2" TA CARRIER 42CE - - MANUFACTURERS: * WILLIAMS, ENVIROTEC, MCQUAY, TRANE GENERAL NOTES:A:^ FIRST VALUE INDICATES NORMAL OPERATING CONDITIONS, SECOND VALUE INDICATES CONDITIONS DURING MAKEUP AIR OPERATION FOR KITCHEN HOOD.B:UNIT LEAKAGE TO BE <=2% OF DESIGN AIR FLOW.MISCELLANEOUS MECHANICAL EQUIPMENT SCHEDULEMARK SERVICE TYPE CAPACITYELECTRICALMANUFACTURER*& MODEL #ACCESSORIES REMARKSKWVOLT/PHGF-1BLDG.GLYCOLFEEDERGLYCOLFEEDER6 GAL50W120/1AXIOM IND.MF200LOW PRESSURE ALARMPANEL-GF-2SNOWMLETGLYCOLFEEDERGLYCOLFEEDER6 GAL.50W120/1AXIOM IND.MF200LOW PRESSURE ALARMPANEL-H-1 SPACE RHHUMIDIFIER2-10 lbs./HR3.8240/1NORTECRH2 DUCTSHORT ABSORPTIONMANIFOLDPROVIDE DRAIN UNDER UNITSAND ALL CONNECTION POINTSSG-1LL STEAMSHOWERSTEAMSHOWER925 CU. FT. 24 240/1MR. STEAMMSSUPER5EITEMPO PLUSCONTROLS, SHAPEAND FINISH BY ARCH-SG-2ML MASTERSHOWERSTEAMSHOWER564 CU. FT. 12 240/1MR. STEAMMSSUPER2EITEMPO PLUSCONTROLS, SHAPEAND FINISH BY ARCH-SG-3UL MASTERSHOWERSTEAMSHOWER613 CU. FT.15240/1MR. STEAMMSSUPER3EITEMPO PLUSCONTROLS, SHAPEAND FINISH BY ARCH-BT-1CHILLEDWATERRES.VERTICALBUFFERTANK100 GAL. - - LOCHINVAR CVL120INTERNAL BAFFLE,ASME 125 PSI, R12INSULATION- MANUFACTURERS: * GENERAL NOTES:A:B:PLUMBING FIXTURE SCHEDULESYMBOL TYPE A.D.A. FINISHMANUFACTURER*& MODEL #FAUCET TRIM MFR.* &MODEL #ACCESSORIES REMARKSFLOOR DRAIN NA CAST IRON ZURN Z415C -TRAP PRIMERCONNECTION3" U.N.O.FLOOR SINK NA A.R.E.ZURN FD2376-12 GRATE3"Ø, U.N.O.ICE MAKER BOX NA WHITEGUY GRAYMIB1-- -WASHER BOX NA WHITEGUY GRAYT200-- -HOSE BIBB NAROUGHBRONZEWOODFORD 19 - -ANTI-SIPHON, FREEZELESSDECK DRAIN NA CAST IRONZURN ZN154-85- UNDERDECK CLAMPMIN. 25 SQ. IN. FREE OPENAREA; 3" U.N.O.DOWNSPOUTNOZZLEN/ASTAINLESSSTEELZURN Z199- - SIZE TO MATCH PIPE SIZEHOT/COLDHOSE BIBBN/AROUGHBRONZEWOODFORD V22 - -FREEZELESS, BACKFLOWPROTECTION MANUFACTURERS:DRAIN: JOSAM, WADE SMITH GENERAL NOTES:A: ALL LAVS, WATER CLOSETS, SHWRS/TUBS, AND ASSOCIATED ACCESSORIES ARE SPECIFIED BY THE ARCHITECT/INTERIORS. RE: ARCH FOR ADDITIONALINFORMATION.B:P1P2P3P4P5P6P7P8SNOWMELT MANIFOLD SCHEDULEZONE DESCRIPTIONAPPROX.AREA(SQ. FT.)GPMESTIMATED #OF LOOPSMAX LOOPPRESSURELOSS (FT)REMARKS1A DRIVEWAY70 0.811.1 -2A DRIVEWAY1,58017.3 10 10.7-3AENTRY1001.1 13.0-4ASTAIRS/BBQ120 1.315.0-5AMAIN MASTERDECK120 1.315.0-6ASPA DECK480 5.345.0-7AUPPER MASTERDECK60 0.710.7 -8ABEDROOMS DECK1101.2 13.9 -1BDRIVEWAY 70 0.610.7 -2BDRIVEWAY1,89015.5126.3 -3B ENTRY 310 2.626.1 -4BSTAIRS/BBQ80 0.711.0 -5BMAIN MASTERDECK90 0.711.3 -6B SPA DECK 560 4.6 4 4.6 -7BUPPER MASTERDECK60 0.510.4 -8B BEDROOM DECK 50 0.410.3 -9B BEDROOM DECK 50 0.410.3 - GENERAL NOTES:A: 3/4"Ø PEX-A TUBING, 9"O.C., 20°F ∆T, 85°F AVG. WATER TEMPB:1. ALL STARTERS AND VFD'S FOR MECHANICAL EQUIPMENT SHALL BE FURNISHED UNDERTHIS CONTRACT AND SET IN PLACE AND WIRED BY EC. EACH SHALL BE OF ONEMANUFACTURER OR AVAILABLE THROUGH ONE MANUFACTURER TO FACILITATE EASEOF MAINTENANCE.2. NOT ALL EQUIPMENT REQUIRED UNDER THIS CONTRACT IS NECESSARILY SPECIFIED ONTHE SCHEDULE SHEETS. PLAN & DIAGRAM NOTATIONS AND PROJECT MANUAL CONTAINEQUIPMENT SPECIFICATIONS AS WELL.3. NOT ALL CAPACITIES, CHARACTERISTICS, AND CONSTRUCTION FEATURES REQUIREDARE NECESSARILY INDICATED IN THE EQUIPMENT SCHEDULES. RE: PLANS ANDSPECIFICATIONS FOR ADDITIONAL REQ'MTS.4. CAPACITIES, CHARACTERISTICS, AND CONSTRUCTION FEATURES OF THE SCHEDULEDEQUIPMENT ARE HEREBY INCORPORATED INTO THE PROJECT REQUIREMENTS.EQUIVALENT PRODUCTS PERFORMANCE AND CONSTRUCTION FEATURES SHALL MEETOR EXCEED THAT OF THE SPECIFIED EQUIPMENT WHETHER SCHEDULED OR NOT.5. NOT ALL EQUIPMENT AVAILABLE FROM LISTED "EQUIVALENT" MANUFACTURERS LISTEDIS NECESSARILY EQUIVALENT TO THE BASIS OF DESIGN EQUIPMENT SPECIFIED.CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY COSTS, RESULTANT CHANGESTO OTHER DIVISIONS, AND SPATIAL REQ'MTS FOR EQUIPMENT OTHER THAN SCHEDULED.SCHEDULE NOTES:HOT WATER GENERATOR SCHEDULEMARK SERVICE TYPE SIDE GPMFLUIDE.W.T.(°F)L.W.T.(°F)MAXPRESSUREDROP (PSI)STORAGECAPACITY(GAL.)MANUFACTURER* &MODEL #ACCESSORIES REMARKSWH-1 DHWVERTICAL,INDIRECTHOT 1430% PG 180 160 5114 LOCHINVAR SIT 119HEAT TRAPS ON INLET ANDOUTLET OF TANKS-COLD - WATER40 120 5 * GENERAL NOTES:A:B:HEAT RECOVERY VENTILATOR SCHEDULEMARK SERVICE TYPEELECTRICAL FANMANUFACTURER*& MODEL #ACCESSORIES REMARKSWATTSVOLT/PHCFM FLAESP@ S.L. (INW.C.)@ ALT (INW.C.)HRV-1WHOLEHOUSEHORIZ.STATICPLATE160120/1150 1.5 0.4 0.3 RENEWAIRE EV200-- MANUFACTURERS: *VENMAR GENERAL NOTES:A:B:182 WEST MEADOW DRIVEVAIL, CO 81657PIETRINI RESIDENCEProject Number - 142807/30/14DESIGN REVIEWCOPYRIGHT 2014BANZEGEAUDIN(970) 949-6108(303) 278-3820(970) 221-5691(505) 323-9070(307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com09/05/14PERMIT SETM0.10MECHANICALSCHEDULES