HomeMy WebLinkAboutM200 BASEMENT PIPING.pdfUPUPDNDNUPUP124356A.1BCDEFGHA1.13.21.2E.1E.2D.2D.13.1NOTES:SCALE:BASEMENT PIPING PLAN3/16" = 1'-0"T2/1TTT2/1T2/1TTSMSSMRSMSSMRCHRCHSHWRHWST2/1CHRCHSHWRHWSSMSSMRSMSSMRHWRHWS3/4" HWS/R UP TO .CHRCHSHWRHWSCHRCHSHWRRADIANTZONE #5BRADIANTZONE #4BRADIANTZONE #2BRADIANTZONE #1BRADIANTZONE #3BRADIANTZONE #4ARADIANTZONE #5ARADIANTZONE #2ARADIANTZONE #3ARADIANTZONE #1ACHRCHSSMSSMRSMSSMR3/4" HWS/R UP TOFLOOR ABOVE.3/4" HWS/R UP TOFLOOR ABOVE.3/4" HWS/R UP TO1-1/4"1-1/4"3/4"3/4"3/4" HWS/R UP TOFLOOR ABOVE.1-1/4" HWS/R, 2" CHS/RUP TO FLOOR ABOVE.2" HWS/R, 2" CHS/R, 2" SMS/R, 1-1/2" CW,1-1/4"HW, 3/4"HWC TO BOILER PLANT ANDCHILLED WATER PUMPS.3/4" HWS/R TO.3/4" HWS/R TO.3/4" HWS/R, 3/4" CHS/R TO .CAP CHS/R LINES FOR FUTURE USE.SMSSMRHWRHWSCHRCHS3/4"3/4"3/4"3/4"1"1"3/4"3/4"3/4" HWS/R TO.3/4" HWS/R TO.3/4" HWS/R, 3/4" CHS/R TO CAP CHS/R LINES FOR FUTURE USE.3/4" HWS/R UP TO3/4" HWS/R UP TO3/4"3/4"1"1"3/4"3/4"1-1/2" HWS/R, 2" CHS/RUP TO FLOOR ABOVE.3/4" HWS/R, 3/4" CHS/R TO CAP CHS/R LINES FOR FUTURE USE.3/4" HWS/R UP TO 3/4" HWS/R TO 3/4" HWS/R TO 3/4"3/4"3/4"HWS/R UP TO 2" HWS/R, 2" CHS/R, _" SMS/R, 1-1/2" CW,1-1/4" HW, 3/4" HWC TO BOILER PLANT ANDCHILLED WATER PUMPS.1"1"3/4"3/4"3/4"3/4"3/4"3/4"3/4" HWS/R, 3/4" CHS/R TO CAP CHS/R LINES FOR FUTURE USE.3/4"3/4"1"1"3/4"3/4"CHRCHSHWRHWS3/4" HWS/R TO .3/4" HWS/R TO .3/4" HWS/R TO 3/4"3/4"3/4" HWS/R UP TO .3/4" HWS/R UP TO .1"SMS/R TO SNOWMELTMANIFOLD #6B.3/4"SMS/R TO SNOWMELTMANIFOLD #4B.3/4"SMS/R UP TO SNOWMELTMANIFOLD #5B.3/4"SMS/R UP TOSNOWMELTMANIFOLD #5A.3/4"SMS/R UP TO SNOWMELTMANIFOLD #4A.1-1/2"SMS/R UP TO SNOWMELTMANIFOLDS #1A, 2A, & 3A.4"W TO MAIN.I.E. = 8139.00G FROM MAIN.G UP.2" COMBINED F/CWFROM MAIN.I.E. = 8139.50'4"W TO MAIN.1-1/2"SMS/R TO SNOWMELTMANIFOLDS #1B, 2B, AND 3B.2" COMBINED F/CW FROM MAIN.4"G UP.G FROM MAIN.1"3/4"3/4"1"1"3/4"3/4" CW, 3/4" HW, 3/4" HWCTO BATHROOM GROUP TYP.2, CDBBC.1-1/4"1"3/4"1-1/4" CW, 1-1/4" HW, 3/4" HWCUP TO FLOOR ABOVE.1-1/2"1-1/4"3/4"1" CW, 3/4"HW, 3/4" HWC TOBATHROOM GROUP, CDBBC.1-1/4" CW, 1-1/4" HW, 3/4"HWC TO FLOOR ABOVE.1"3/4"3/4"1" CW, 3/4" HW, 3/4" HWC TOBATHROOM GROUP, CDBBC.1"1"3/4"1"1"3/4"1" CW, 3/4" HW, 3/4" HWCTO KITCHEN FIXTUREGROUP, CDBBC.1/2" HW, 1/2" CW UP TOISLAND SINK ABOVE.1. RE: M4 SERIES FOR PIPING DIAGRAMS.2. COORDINATE ROUTING OF CONDENSATE DRAIN LINESWITH ARCHITECT PRIOR TO INSTALLATION.3. PIPING ON EXTERIOR WALLS TO BE ROUTED INFRAMED WALL ON INTERIOR SIDE OF INSULATION.4. AVOID ROUTING PIPING OVER ELECTRICAL ROOMS ORELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES.COORDINATE ROUTINGS WITH DIV. 16 CONTRACTOR.5. PROVIDE FLEXIBLE PIPE CONNECTIONS TO ALLMOTORIZED EQUIPMENT.6. VERIFY ALL EQUIPMENT ACCESS PANELS WITHMANUFACTURER AND ARCHITECT.7. PEX PIPING SHALL NOT BE ALLOWED TO PENETRATEFIRE BARRIERS WHERE FIRE CAULKING IS REQUIRED.8. ALL BRANCH CHILLED AND HEATING WATER PIPING TOFAN COIL UNITS SHALL BE 3/4" U.N.O.9. ALL VALVES SHALL BE INSTALLED WITH ACCESSPANELS IN HARD-LID CEILINGS.10. ALL PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE INTHE CEILING SPACE. UTILIZE JOIST SPACE WHENPOSSIBLE, ESPECIALLY WHERE CROSSING OTHERPIPES, DUCTS, AND ELECTRICAL.11. ACCESS PANELS SHALL BE 24x24, U.N.O. LOCATIONSSHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALLBE COORDINATED WITH THE ARCHITECTS DRAWINGSAND WITH THE LOCATIONS OF THE EQUIPMENT ORAPPARATUS THAT THEY SERVE.12. REFER TO THE PLUMBING FIXTURE CONNECTIONSCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES.13. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILYSHOWN ON THESE PLANS. PROVIDE CLEANOUTS ONWASTE, VENT AND STORM PIPING AS REQUIRED BYCODE AND FOR REASONABLE MAINTENANCE BASEDON ACTUAL FIELD INSTALLATION. COORDINATELOCATIONS WITH ARCHITECT/ENGINEER.14. ST AND ST(OF) PIPING 3", U.N.O.15. ROOF OVERFLOW DRAINAGE STRATEGY TO BEDETERMINED OR VIA ARCHITECTURAL SCUPPERSU.N.O.16. TERMINATE PLUMBING VENTS NOT LESS THAN 12"ABOVE ROOF.17. ROUTE DOMESTIC HOT WATER RECIRC TO WITHIN 10FEET OF ALL HOT WATER FIXTURES. CONNECT WITHIN5 FEET OF 0.5 GPM AND LOWER FAUCETS.G UP TO FIREPLACE.G TO FIREPLACE.G UP TO RANGE.G UP TO FIREPLACE.G UP TO BBQ.G UP TO FIREPLACE.G UP TO BBQ.G UP TO RANGE.1" CW, 3/4"HW, 3/4" HWC TOBATHROOM GROUP. CONTINUATIONDESIGN/BUILD BY CONTRACTOR.GGG TO FIREPLACE.1-1/2"1-1/2"1"1"GGG TO OUTDOORFIREPLACE.3/4"3/4"GHWSSPACE RESERVED FOR COMBINEDFIRE/DOMESTIC WATER ENTRIES.G TO BOILERS.SPACE RESERVED FOR COMBINEDFIRE/DOMESTIC WATER ENTRIES.2"2"_"G UP.GGGG TO FIREPLACE.1"SMS/R UP TO SNOWMELTMANIFOLD #6A.G TO OUTDOORFIREPLACE.3/4"3/4"1"G TO BOILERS.3/4" SMS/R UP.1"2"CHS/R TO CHILLER PLANT.CHSCHR2"CHS/R TOCHILLER PLANT.CHSCHRCHSCHR4"ø RADON PIPE RISER.4"ø RADON PIPE UP. STUBPIPING INTO SUB-SLABASSEMBLY I.A.W. 2012IRC, APPENDIX F, AF103.6.4"ø RADON PIPE UP. STUB PIPINGINTO SUB-SLAB ASSEMBLY I.A.W.2012 IRC, APPENDIX F, AF103.6.3/4"182 WEST MEADOW DRIVEVAIL, CO 81657PIETRINI RESIDENCEProject Number - 142807/30/14DESIGN REVIEWCOPYRIGHT 2014BANZEGEAUDIN(970) 949-6108(303) 278-3820(970) 221-5691(505) 323-9070(307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com09/05/14PERMIT SETM2.00 BASEMENTPIPING PLAN