HomeMy WebLinkAboutM210 MAIN PIPING.pdfDNUPDNDNUPDNDNDNUPUP1243A.1BCDEFGHA1.13.21.2E.1E.2D.2D.13.1NOTES:SCALE:MAIN FLOOR PIPING PLAN3/16" = 1'-0"TTTT2/12/12/12/1TTTTTHWSHWRCHSCHRHWSHWRCHSCHRCHRCHSHWRHWSHWRHWSRADIANTZONE #10BRADIANTZONE #10ARADIANTZONE #6ARADIANTZONE #7ARADIANTZONE #8ARADIANTZONE #9BRADIANTZONE #8BRADIANTZONE #7BRADIANTZONE #6BRADIANTZONE #9ACHRCHSHWRHWSSMSSMRSMSSMR3/4" HWS/R UP TO.3/4" HWS/R UP TO.3/4" HWS/R UPTO 3/4" HWS/R UPTO .3/4" SMS/R UP TOSNOWMELTMANIFOLD #7B.3/4" HWS/R UP TO 3/4" HWS/R UPTO .3/4" HWS/R, 1-1/4" CHS/RUP TO FLOOR ABOVE.3/4" HWS/R, 3/4"CHS/R TO .1-1/4"1-1/4" HWS/R, 1-1/4" CHS/RTO .3/4" HWS/R UPTO .3/4" HWS/R UPTO .1-1/2" HWS/R DOWN, 1"HWS/R UP. 2" CHS/RDOWN, 1-1/4" CHS/R UP.1-1/4"1-1/4"1-1/4"3/4" HWS/R TO.3/4" HWS/R TO.1-1/4"1-1/4"1-1/4"1-1/4"3/4" HWS/R, 3/4" CHS/RTO .3/4"3/4"3/4" HWS/R UPTO .3/4" HWS/R UPTO .1-1/4" HWS/R, 1-1/2" CHS/RTO 3/4"SMS/R UP TOSNOWMELTMANIFOLD #7A.HWS/R, CHS/R, &SMS/R DN.3/4"SMS/R UP TOSNOWMELTMANIFOLD #9B.3/4"SMS/R UP TOSNOWMELTMANIFOLD #8B.3/4"SMS/R UP TO SNOWMELTMANIFOLD #8A.C.O.T.G.MC.O.T.G.M1-1/4" CW, 1-1/4" HW, AND3/4" HWC FROM BELOW.1" CW, 1" HW, 3/4" HWC TOBATHROOM GROUP, CDBBC.1-1/4" CW, 1-1/4" HW, 3/4"HWC UP TO FLOOR ABOVE.3/4" CW, 1/2" HW, 3/4" HWC TOBATHROOM GROUP, CDBBC.1"3/4"3/4"3/4" CW, 3/4" HW, 3/4" HWCTO BATHROOM GROUP,CONTINUATIONDESIGN/BUILD BYCONTRACTOR.1/2" CW, 3/4" HW, 3/4" HWCTO KITCHEN FIXTUREGROUP, CONTINUATIONDESIGN/BUILD BYCONTRACTOR.3/4" CW, 3/4" HW, 3/4" HWCTO BATHROOM GROUP,CONTINUATIONDESIGN/BUILD BYCONTRACTOR.1"3/4"3/4"1-1/4" CW, 1-1/4" HW, 3/4"HWC UP TO FLOOR ABOVE.1" CW, 1" HW, 3/4" HWC TOBATHROOM GROUP, CDBBC.1-1/4" CW, 1-1/4" HW, 3/4" HWCFROM FLOO BELOW.1. RE: M4 SERIES FOR PIPING DIAGRAMS.2. COORDINATE ROUTING OF CONDENSATE DRAIN LINESWITH ARCHITECT PRIOR TO INSTALLATION.3. PIPING ON EXTERIOR WALLS TO BE ROUTED INFRAMED WALL ON INTERIOR SIDE OF INSULATION.4. AVOID ROUTING PIPING OVER ELECTRICAL ROOMS ORELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES.COORDINATE ROUTINGS WITH DIV. 16 CONTRACTOR.5. PROVIDE FLEXIBLE PIPE CONNECTIONS TO ALLMOTORIZED EQUIPMENT.6. VERIFY ALL EQUIPMENT ACCESS PANELS WITHMANUFACTURER AND ARCHITECT.7. PEX PIPING SHALL NOT BE ALLOWED TO PENETRATEFIRE BARRIERS WHERE FIRE CAULKING IS REQUIRED.8. ALL BRANCH CHILLED AND HEATING WATER PIPING TOFAN COIL UNITS SHALL BE 3/4" U.N.O.9. ALL VALVES SHALL BE INSTALLED WITH ACCESSPANELS IN HARD-LID CEILINGS.10. ALL PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE INTHE CEILING SPACE. UTILIZE JOIST SPACE WHENPOSSIBLE, ESPECIALLY WHERE CROSSING OTHERPIPES, DUCTS, AND ELECTRICAL.11. ACCESS PANELS SHALL BE 24x24, U.N.O. LOCATIONSSHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALLBE COORDINATED WITH THE ARCHITECTS DRAWINGSAND WITH THE LOCATIONS OF THE EQUIPMENT ORAPPARATUS THAT THEY SERVE.12. REFER TO THE PLUMBING FIXTURE CONNECTIONSCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES.13. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILYSHOWN ON THESE PLANS. PROVIDE CLEANOUTS ONWASTE, VENT AND STORM PIPING AS REQUIRED BYCODE AND FOR REASONABLE MAINTENANCE BASEDON ACTUAL FIELD INSTALLATION. COORDINATELOCATIONS WITH ARCHITECT/ENGINEER.14. ST AND ST(OF) PIPING 3", U.N.O.15. ROOF OVERFLOW DRAINAGE STRATEGY TO BEDETERMINED OR VIA ARCHITECTURAL SCUPPERSU.N.O.16. TERMINATE PLUMBING VENTS NOT LESS THAN 12"ABOVE ROOF.17. ROUTE DOMESTIC HOT WATER RECIRC TO WITHIN 10FEET OF ALL HOT WATER FIXTURES. CONNECT WITHIN5 FEET OF 0.5 GPM AND LOWER FAUCETS.G TO FIREPLACE.3/4" SMS/R DN.G UP TO FIREPLACE.GGGGAS UTILITY METER AND PRVASSEMBLY. 2,206 MBH (APPROX.)AND 0.5 PSI DISCHARGE PRESSURE.GAS UTILITY METER ANDPRV ASSEMBLY. 2,206CFH (APPROX.) AND 0.5PSI DISCHARGEPRESSURE.3/4"3/4"G TO FIREPLACE.G UP TO FIREPLACE.G TO RANGE.GG TO FIREPLACE.G TO BBQ.G TO FIREPLACE.G TO BBQ.G TO RANGE.4"ø RADON PIPE RISER.4"ø RADON PIPERISER.4"ø RADON PIPE RISER.182 WEST MEADOW DRIVEVAIL, CO 81657PIETRINI RESIDENCEProject Number - 142807/30/14DESIGN REVIEWCOPYRIGHT 2014BANZEGEAUDIN(970) 949-6108(303) 278-3820(970) 221-5691(505) 323-9070(307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com09/05/14PERMIT SETM2.10 MAIN FLOORPIPING PLAN